We are Manufacturer of cold storage, cold room as per customer requirment.We used high quality raw material from renowned manufacturer in India.
We, svar projects, one of the leading company engaged in manufacturing and supply of chris eco-friendly air ventilators (ceav) since 2001. We focus on quality and aim to achieve total customer satisfaction, both in products as well as in the services. Our corporate strategy is to design, manufacture and supply standard quality products backed by total solution for installation, commissioning and trouble shooting. 21"dia 24"dia 14"dia
WIth Digital Display of Humidity (RH%).Suitable for 150 Sq Ft of close room. for Domestic & Inustrial applications. with inbuilt Water collection Tank. 9 Kg Portable.
Technical Specification Model Standard CEAV Diameter 28 Inch (710mm) Neck/Throat Diameter 21 Inch (530mm) No. of Vanes(Blades) 36 Vanes Height 19 Inch (480mm) Base Ring Stainless Steel (Jindal make) Top Cover Stainless Steel (Jindal make). Top Plate MOC Aluminium 1 mm Thickness Alloy 8011 H2 Vanes MOC Aluminium 0.635mm Thickness (Hindalco make) Bottom Ring Aluminium 1.27 mm Thickness (Hindalco make) Rotation Pivot bush support w/o Bearing Pointer MOC 10 mm Ø EN-8 with Electroplating Supporting bush MOC Derline black( Hardest PTFE grade) Center Shaft M.S. 20mm Ø with Nickle Plating Inner Arms M.S. with Electroplating Outer Arms M.S. with Electro Plating Center Pipe M.S. with Electro Plating Nett. Weight 5.8 Kgs (Approx.) Packing As per requirement.
Outer frame : Aluminium / Galvanise Louver Blade: 2" , 3" ,4" wide Aluminium/Galvanise Finish : Powdercoated or Anodised (for Alu.) Minimum order 2500 Sft
AL Humidifier complete with + HP Electric motor with or without starter, ceiling hanger, good for 400/440 Volts, 50 cycles, 3 phase, AC supply. The unit is capable of handling 2400 cu.ft. air per minute and evaporate up to 40 liters of water per hour. Wooden box having the size of 25" x 25" x 25" and Weight approx. 80 Kgs Gross.
For removing hot air., fumes, smoke, irreating smel from the production area, Driven by wind and did not required electricity 50 no.
Apart from manufacturing the fans for various applications, we are one of the few leading names to offer cellulose pads. We offer various types of cellulose pads like evaporative cooling pad (ecp). Made of cellulose paper, this product is engineered from cross-sectional, specially treated flute media capable of absorbing and retaining water to provide the maximum cooling efficiencies. The cellulose media is treated with stiffening and wetting agents to provide the cooling without any water carryover. These pads are designed for tropical and subtropical countries, ensures greatest performance during summer seasons. The pad media is treated with anti-rot and rigidifying resins. The media is cross-corrugated to maximize the mixing of air and water. Saturation efficiency ranging from 50 to 98%, can be achieved depending upon air velocity and depth of the cooling pad. á
Humiair offers effective, turnkey solutions with regard to Ventilation for office/factory. With a strong engineering and design Set up and efficient project management, we provide quality Services and support to ensure that you have a reliable and Efficient system commissioned on time. We provide General/forced draft ventilation system Pressurization system Balanced ventilation system Humiair misting
The air ventilator manufactured by ambica engineering works functions without electricity, leaving no scope for any kind of shock or short circuit. It works by utilizing wind energy to induce air flow by centrifugal action. Huge choice of selecting ventilators is offered to our customers ranging from 16" to 36" diameter and of various material of construction for any working atmosphere. Our entire chain of products includes:
High quality and guaranteed thermal performance High efficiency pvc fills & nozzles with low pressure drop. Minimize noise & carry over Modular capabilities, single cell to multi cells installation Weather proof, rust resistant and easy maintenance Space saving, lightweight and easy installation Piece/pieces
Crossflow is a design in which the air flow is directed perpendicular to the water flow air flow enters one or more vertical faces of the cooling tower to meet the fill material. Water flows (perpendicular to the air) through the fill by gravity. The air continues through the fill and thus past the water flow into an open plenum area. A distribution or hot water basin consisting of a deep pan with holes or nozzles in the bottom is utilized in a crossflow tower. Gravity distributes the water through the nozzles uniformly across the fill material. Piece/pieces
Water fog system for cooling the outdoors and for creating mind-boggling visual effects.
FOG system is used for cooling the outdoors by upto 17¦C. And FOG can bring the hill station climate in your backyard 24X7, 365 days a year.
Fog system generates very fine droplets in the range of 20 microns and less which attack the floating dusts particles and making them heavier settle them on the ground thus rendering the atmosphere clean.
Comes in many sizes, used fo exhausting hot air, fumes, bad smel 30" x 30" x 22"
The air ventilator is a revolutionary conceptual product which exhausts the hot gases from an enclosed area without using any electric power. Yes absolute zero power consumption. It has no operating cost and gives excellent ventilation performance making the work areas like boiler / furnace / oven sheds, curing and drying areas, casting and molding sheds, workshops, process area utility sheds, dg sheds, compressor houses, power house and packing area, go-downs, etc more cooler and comfortable to work in. The air ventilators are most cost effective substitute to the exhaust fans which continuously gulp the electric power and also have maintenance problems.
The air ventilator is a revolutionary conceptual product which exhausts the hot gases from an enclosed area without using any electric power. Yes absolute zero power consumption. It has no operating cost and gives excellent ventilation performance making the work areas like boiler / furnace / oven sheds, curing and drying areas, casting and molding sheds, workshops, process area utility sheds, dg sheds, compressor houses, power house and packing area, go-downs, etc more cooler and comfortable to work in. The air ventilators are most cost effective substitute to the exhaust fans which continuously gulp the electric power and also have maintenance problems
ò Large TFT Screen for Settings, Alarms, Messages, And Graphics û Pressure V/s Time, Flow V/s time. ò ACTIVE û Inspiratory and ACTIVE Expiratory Phase. ò I : E Ratio û 1:1 and 1: 2 Allowing Inspiration times of 50% and 33 %. ò SERVO Controlled û Bias flow 4 to 60 LPM with Digital Display of Flow. ò SERVO Controlled MAP û 4 to 40 Cm H2O ò Amplitude û 0 to 100 ò Frequency û 5 to 18 Hz. ò DCO2 in Numerical Value, to help in Non Invasively Monitory Pulmonary Mechanics. ò Digital Display of Tidal Volume. ò Differential Pressure Indication. ò Inbuilt Humidifier and Air Oxygen Blender. ò Oil free Dry Air Compressor. ò Less Compliant Reusable Patient Tubing. ò Castor Wheels with Brakes. Per Unit
Available in class 100 to 1000000. Grade a to d To meet cgmp, whi and iso requirement for pharma units