Please click here to check who's online and chat with them.

Find Verified Glass Ceramics Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : -   Morbi   Mumbai  
GOLD Member
Apr-18-25
 
Fully Autoclavable Single Channel Adjustable Volume Pipette

A rotary button cap ensures smooth and stable.

Each model has color mark with different color to show volume range.

The handle is made of high-quality materials with an adequate thickness to minimize the impact of palm temperature on the volume.

A whole autoclaved single-channel adjustable pipette is a laboratory instrument used for precise liquid handling.

It can measure and dispense specific volumes of liquid accurately.

The autoclaving process sterilizes the entire pipette making it suitable for sterile environments and experiments requirng contamination free operations.

Specifications:-

Product Name

Fully autoclaved single channel adjustable pipette

MODEL
SAP20
SAP100
SAP200
SAP1000


Volume  Range
2-20 µl
10-100 µl
20-200 µl
100-1000 µl


Increment

Tes Volume µl
0.002 µl
0.2 µl
0.2 µl
2 µl


2
10
20
10
50
100
20
100
200
100
500
1000


Accuracy  %
5
1
1.50
1.20
0.80
0.80
2
1
1
1.50
0.80
0.80


Precision  %
1.5
0.6
0.5
0.60
0.30
0.20
0.50
0.40
0.30
0.40
0.30
0.20


Dimension
275 75 45  mm

Gross Weight

190g
GOLD Member
Apr-18-25
 
Fully Autoclavable Single Channel Adjustable Volume Pipette

A rotary button cap to ensure smooth and stable liquid transfer.

Each model has color mark with a different color to show the volume range.


Specifications:-


MODEL
SAP20
SAP100
SAP200
SAP1000


Volume  Range
2-20 µl
10-100 µl
20-200 µl
100-1000 µl


Increment

Test  Volume µl
0.002 µl
0.2 µl
0.2 µl
2 µl


2
10
20
10
50
100
20
100
200
100
500
1000


Accuracy  %
5
1
1.50
1.20
0.80
0.80
2
1
1
1.50
0.80
0.80


Precision  %
1.5
0.6
0.5
0.60
0.30
0.20
0.50
0.40
0.30
0.40
0.30
0.20


Dimension
275 75 45  mm


Gross  weight
190g
GOLD Member
Apr-18-25
 
An ergonomic handle hook design for easy grip in the palm.

Unique design for the tip eject button.

A Clear reading window.

The pipete can be half autoclaved at 121C

A tip one made of durable chemical materials with excellent chemical corrosion resistance.

Ease of calibration and maintenance.


Availability for high temperature and high pressure.



disinfection of part of the device.

Specifications:-



PRODUCT NAME
SINGLE CHANNEL DIGITAL PIPETTES


MODEL
SVP20
SVP50
SVP100
SVP200
SVP1000
SVP5M
SVP10M


Volume Range
2-20µl
5-50µl
10-100µl
20-200µl
100-1000µl
1-5ml
1-10ml


Increment
0.5µl
0.5µl
1µl
1µl
5µl
0.05ml
0.1ml
GOLD Member
Apr-18-25
 
FEATURES:-


An ergonomic handle hook design for easy grip in the palm.

Unique design for the tip eject button.


Clear reading window.

The pipete can be half autoclaved at 121C.

Tip one made of durable chemical materials with excellent chemical corrosion resistance

Ease of calibration and maintenance.


Availability for high temperature and high pressure.

disinfection of part of the device.

Specifications:-



PRODUCT NAME
SINGLE CHANNEL DIGITAL PIPETTES


MODEL
SVP20
SVP50
SVP100
SVP200
SVP1000
SVP5M
SVP10M


Volume Range
2-20µl
5-50µl
10-100µl
20-200µl
100-1000µl
1-5ml
1-10ml


Increment
0.5µl
0.5µl
1µ
1µl
5µl
0.05ml
0.1ml


Test Volume

20
10
2
50
25
5
100
50
10
200
100
20
1000
500
100
5
2.5
1
10
5
1


Accuracy %
0.9
1.2
3
0.6
0.9
2
0.8
1
3
0.6
0.8
3
0.6
0.7
1.5
0.5
0.6
0.7
0.6
0.8
3


Accuracy
0.18
0.12
0.06
0.3
0.225
0.1
0.8
0.5
0.3
1.2
0.8
0.6
6
3.5
2
25
15
7
60
60
30


Precision %
0.4
1
2
0.3
0.6
2
0.15
0.4
1.5
0.15
0.3
1
0.2
0.25
0.7
0.15
0.3
0.3
0.2
0.3
0.6


Precision
0.08
0.1
0.04
0.15
0.15
0.1
0.15
0.2
0.15
0.3
0.3
0.2
2
1.25
0.7
7.5
7.5
3
20
15
6


Dimension
275 7545 mm


Gross weight
190g
GOLD Member
Apr-18-25
 
It is required in biotechnology, Molecular Biology applications in colleges, Universities, Research Institutes.

Design : College Model Transilluminator

Model : TI-20

Wavelength : 365mm with filter to show bands clearly

No. of U.V. Tubes : 8 Imported

Wattage : 8 Watts.

Blue Plate Area : 185x185 mm approx.

Body : MS with poder coated.

UV Protection Shield
9693 Glass Ceramics Suppliers
Short on time? Let Glass Ceramics sellers contact you.
GOLD Member
Apr-18-25
 
These are research models of Tranilluminator. We have 3 model detailed as under.

Specifications.



Parameters
Model: TI-50
Model: TI-60
Model: TI-40


Item
U. V. Transilluminator smart look, very accurate, research work
U. V. Transilluminator smart look, very accurate� � research work accurate for research
Ultra thin U. V. Transilluminator very for small look Portable, very work.


Dual Intensity
302mm
302 and 365mm
302 mm


No. of Tubes
6
6
LED base


Wattage
8 Watts
8 Watts
LED base


Detection limit
0.01 ngm. of stained D.N.A.
0.01 ngm. of stained D.N.A.
0.01 ngm of stained DNA


View Area
210x260mm
210x260mm
150x80mm


Filter
Quartz UV filter
Quartz UV filter
Quartz UV filter


Body
Alluminium Pressure die casted body furnished in Black Pouder coating.
Alluminium Pressure die casted body furnished in Black Pouder coating.
Alluminium Pressure die casted body furnished in Pink Pouder coating.


UV Protection Shield
Yes
Yes
Yes
GOLD Member
Apr-18-25
 
It is required in biotechnology, Molecular Biology applications in colleges, Universities, and Research Institutes.

It is meant for nucleic acid (DNA) characterization.

These are also called submarine electrophoresis unit/agrose gel/poly

The unit is jointless, moulded of transparent polycarbonate to avoid leakae.

It is fitted with 2 platinum electrodes and supploed with a transparent jointless safety lid which is also made of polycarbonate.
The unit is jointless mouldeed of trabsparent polycarbonate to avoid leakage.
GOLD Member
Apr-18-25
 
It is required in biotechnology and molecular biology applications in colleges. universities research institutes.

It meant for protein characterization.

The buffer chamber is jointless, moulded of transparent polycarbonate to avoid leakage. The unit is based on acrylic sheet fitted with 3 leveling screws.

Complete with acrylic cover.

Technical Parameter.

4 dimensions (Outer) (LxWxH) 15x18x15 cm

4 Gel Size (cm) 8cx7 ) Gel
4 Buffer required (ml) 100+150

4 Platinum Electrodes
2 Nos.
GOLD Member
Apr-18-25
 
Specifications.

1. Analog Model with fixed current 250mA and also 5 types of fixed voltage means 50V. 100V. 150V. 200V and 250V.

2. It is recommended for mini Horizontal and mini vertical Electrophoresis Apparatus.

3. The voltage is selected thru a 5 step voltage regulator. Example if selector swich is at 1 position. The LED light will glow at 50 V means fixed voltage of 50V is selected. Like wise other voltage can be selected.
GOLD Member
Apr-18-25
 
SALIENT FEATURES:

1. Full wavelength scanning (190-1100nm) covers UV, Vis. near IR.


2. Fully sealed structure, all optical mirrors are equipped with SiO2 protective film to avoid stray light caused by dust and corrosive gas.


3. Core components reduce the stray light and improve the stability and reliability.


4. Double beam optical system with precision vertical-type dual optical path and dual detector.


5. Grating of high performance greatly reduces the stray light and improves the stability and reliability of device.� 


6. 10 inches large touch screen, built-in 32GB memory.


7. Powerful data analysis system with internal computer could realize multi functions independently. Like establishing calibration curve, photometric measurement, quantitative measurement, spectral scanning, dynamics, DNA/Protein test, multi-wavelength analysis and data printing.


8.� � W Lamp / D2 Lamp can monitor of usage hours.


9. Data can export in Pendrive directly


10. Convenient data storage and printing function. LUV Series can be directly connected to the printer HP DESKJET 2723 for A4 paper data and graph printing.


11. Automatic power ON self test and system positioning function could inspect and calibrate the deviation before every use.� 


12. All test data and analysis report can be exported to USB disk directly.


13. Graphs support 3D display,


14. PC software follows GLP & GMP standards, user management, logging, data tracking, etc. mostly as per 21CFR Part 11.



 

Specifications:



MODEL
LUV2000T� � � � � � � � � � � � � � � LUV2100T


Bandwidth
1.0nm� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1.0, 2.0, 4.0,5.0 nm (variable)


Make
LABMAN


Optical System
Double beam


Wavelength Range
190-1100nm


Wavelength Accuracy
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � +0.1nm(D2 656.1nm),+0.3 nm full range


Wavelength Repeatability
+0.1nm


Photometric Range
� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 0-200%T. -0.3-3.0A, 0-9999C


Photometric Accuracy
+0.2T(0-100%T), +0.002Abs(0-0.5Abs),+0.004Abs(0.5-1.0Abs )


Photometric Repeatability
<0.05%6T(0-100%6T), 0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs)


Stability
+0.0004A/h @ 500nm


Stray Light
0.03%T @ 220 nm, 360 nm


Cell Holder
10mm each, Sample & Reference Cuvette Holder


Focal Length
10mm


Light Source
Tungsten Lamp & Deuterium lamp


Resolution
0.1nm


Display
Touchscreen 10-inches (800 x 480) HD TFT


Memory
32GB


Detector
Silicon Photodiode


Control Mode
Stand-alone system/PC software


Baseline flatness
+0.0008A/h


Data Output
USB


Power Supply
Adaptor, Using AC 220V,50/60Hz


Dimension (L x W x H
GOLD Member
Apr-18-25
 
MODEL
LUV1100T


Bandwidth
2.0nm


Make
LABMAN


Optical System
Single beam


Wavelength Range
190-1100nm


Wavelength Accuracy
+0.5nm


Wavelength Repeatability
+0.2nm


Photometric Range
0-200%T. -0.3-3.0A, 0-9999C


Photometric Accuracy
+0.2T(0-100%T), +0.002Abs(0-0.5Abs),+0.004Abs(0.5-1.0Abs )


Photometric Repeatability
<0.1%T(0-100%T), 0.001Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs)


Stability
+0.001A/h @ 500nm


Stray Light
0.05%T @ 220 nm, 360 nm


Cell Holder
10mm each, Sample & Reference Cuvette Holder


Focal Length
10mm


Light Source
Tungsten Lamp & Deuterium lamp


Resolution
0.1nm


Display
Touchscreen 10-inches (800 x 480) HD TFT


Memory
32GB


Detector
Silicon Photodiode


Control Mode
Stand-alone system/PC software
GOLD Member
Apr-17-25
 
SALIENT FEATURES:

The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy.

Lamp selection enables consrving the life of D2 tungsten lamp. Real time clock for date time stamping of results.

LIGHT PATH DESING : DOUBLE BEAM

LMSPUV1900 double light design can prevent circuit fluctuation and stray light to ensure stability of the instrument

LONG PATH LIGHT DESIGN


16MM OPTICAL BASE

Specifications:



Model
LMSPUV1900
LMSPUV1908LMSPUV1920 LMSPUV1928


Sample Cell Holder
1Omm Cell Holder
8ceII holder programable1Omm1Omm Cell Holder 8ceII holder programable 1Omm


Bandwidth
(variable)


Reference Cell Holder
� 
10 Cell Holder


Make
� 
LABMAN


Optical System

Double Beam(1200 Lines/mm Grating)


Wavelength Range

190-1100nm


Bandwidth
� 
1nm


Wavelength Accuracy
� 
+0.3nm


Wavelength Repeatability
� 
+0.2nm


Scanning Speed

Fast, Medium & Low


Photometric Accuracy

+0.3%T


Photometric Repeatability

0.2%T


Photometric Range

-0.3-3A,0-200%T,0-9999C


Stability
� 
+ 0.001A/h @ 500nm


Baseline Flatness
� 
+ 0.001A/h


Noise
� 
+ 0.001A/h


Stray Light
� 
<0.05%T @ 220nm,360nm


Data Output Port
� 
USB


Printer Port
� 
Parallel Port


Display
� 
LCD


Light Source
� 
D2 Lamp & Tungsten Halogen Lamp (W Lamp)


Detector
� 
Silicon Photodiode


Power Supply
� 
AC 220V,50/60Hz


Dimension & Weight
� 
625x430x206 mm & 30kg
GOLD Member
Apr-17-25
 
The two detectors are used to measure sample and reference, respectively and simultaneously for optimizing measurement accuracy.

Lamp selection enables conserving the life of D2 tungsten lamp. Real-time clock for date time stamping of results.

Light Path Design : Double Beam

LMSPUV1900 double lightt design can prevent circuit fluctuation and stray light to ensure stability of the instrument.

LONG PATH LIGHT DESIGN

LMSPUV1900 unique 520mm long light path design greatly improved resolution and the bandwidth can reach 0.5nm.

16MM OPTICAL BASE
LMSPUV1900 series use a rigid 16mm diecast aluminum base as their optical mount to ensure the stability and reliablity.

6 Inches LCD Display

LMSPUV1900 series have a 6A inches LCD display to show results and curves directly on the screen.


DATA OUTPUT


Specifications:



Model
LMSPUV1900
LMSPUV1908 LMSPUV1920 LMSPUV1928


Sample Cell Holder
1Omm Cell Holder
8ceII holder programable1Omm 1Omm Cell Holder  8ceII holder programable 1Omm


Bandwidth
 1.0, 2.0, 4.0 nm (variable)


Reference Cell Holder

10 Cell Holder


Make

LABMAN


Optical System
Double Beam(1200 Lines/mm Grating)


Wavelength Range

190-1100nm


Bandwidth

1nm


Wavelength Accuracy

+0.3nm


Wavelength Repeatability
+0.2nm


Scanning Speed

Fast, Medium & Low


Photometric Accuracy

+0.3%T


Photometric Repeatability

0.2%T


Photometric Range
-0.3-3A,0-200%T,0-9999C


Stability
+ 0.001A/h @ 500nm


Baseline Flatness

+ 0.001A/h


Noise

+ 0.001A/h

Stray Light

0.05%T @ 220nm,360nm


Data Output Port

USB


Printer Port

Parallel Port

Display

LCD

Light Source

D2 Lamp & Tungsten Halogen Lamp (W Lamp)

Detector
 
Silicon Photodiode
Custome
GOLD Member
Apr-17-25
 
Specifications:

# Suitable for Spectrophotometers

# It is used to the Control Sample Temperature

# Temperature range - 15�°C to 65�°C

# Time range - 30sec to 10min.

# Peristaltic pump speed range - 1 to 12
GOLD Member
Apr-17-25
 
SALINT FEATURES:

Microprocessor controlled all parameter of this instrument can be easily set by numerical keys.

8MM THICK OPTICAL BASE

The instruments use a rigid die cast aluminum base as its optical mount to ensure instrument stability and reliability.

Standard Curve

Can set up various standard curves according to customer solution and find the concentration of unknown solutions.

Auto setting wavelength

User set the wavelength automatically through arrow keys to avoid operation errors.

Data Outpout


This instrument  uses imported flanged deuterium  lamp with low stray light, photometric accuracy and easy replacing


Data can be restored after a suddeb power cut,

Tungsten lamp deuterium lamp can be turned on/off individually to extend shelf life

Large sample compartment it can accommodate 5-100mm path length cuvettes with optional holders.

Specifications:

Plodel
LNISPUV1200


Make
LABMAN


Wavelength Range
190-1100nm


Bandwidth
2nm


Optical System
Single Beam, Grating 1200 lines / mm


Wavelength Accuracy
+0.8nm


Wavelength Repeatability
+ 0.2nm


Wavelength Setting
Automatic


Photometric Accuracy
+0.3%T


Photometric Repeatability
+ 0.2%T


Photometric Range
-0.3-3A,0-200%T


Stability
+ 0.002A/h @ 500nm


Baseline Flatness
+ 0.002A/h


Stray Light 0.05 % T


Data Output
USB


Printer Port
Parallel Port


Display
LCD


Cell Holder
10 mm 4 position cuvette holder


Light Source
D2 Lamp & Tungsten Halogen Lamp ( W Lamp )


Detector
Silicon Photodiode


Power Supply
AC 220V,50/60Hz


Dimension (LxWxH) mm
460x360x225mm


Weight
18kg
GOLD Member
Apr-17-25
 
SALIENT FEATURES:

LOW STRAY LIGHT


LMSPUV1000B uses a rigid die-cast aluminum base as Its optical mount to ensure instrument� stability and Reliability.

STRANDED CURVE


LMSPUV1000B
Users can set wavelength automatically through arrow keys to avoid operation errors.

DATA OUTPUT

Specifications:



Model
LMSPUV1000B


Make
LABMAN


Optical System
Single beam, Grating 1200 lines/mm


Wavelength Range
190-1000nm


Bandwidth
2nm


Wavelength Accuracy
+1nm


Wavelength Repeatability
+0.5nm


Wavelength Setting
Automatic.


Photometric Accuracy
+0.5%T


Photometric Repeatability
+0.3%T


Photometric Range
-0.3-3A,0-200%T


Stray Light
s0.3%T


Stability
+ 0.002A/h @ 500nm


Display
LCD


Detector
Silicon Photodiode


Standard Cell Holder
4-position 10mm cell holder


Light Source
D2 lamp & Tungsten Halogen Lamp ( W Lamp)


Output
USB Port & Parallel Port(Printer)


Power Supply
AC 220V,50/60Hz


Dimension (LxWxH) mm
490 x 370 x 220


Weight
15kg
GOLD Member
Apr-17-25
 
Specifications:

# Suitable for Spectrophotometers

# It is used to the Control Sample Temperature

# Temperature range - 15�°C to 65�°C

# Time range - 30sec to 10min.

# Peristaltic pump speed range - 1 to 12
GOLD Member
Apr-16-25
 
Product Description

LABMAN LMION40 ion meter is designed for high performance and easy operation. The meter is capable of measuring up to 7 parameters, including�  ION concentration,pH, ORP Conductivity, TDS, Salinity, Resistivity, and temperature.

Features:

Ion concentration mode directly displays readings in ppm, ppt, or any other units of your choice
Calibrate up to 2 points for pH using USA or NIST buffer sets; Up to 5 points for ion concentration measurement
Auto-buffer recognition eliminates calibration mistakes and ensures calibration accuracy
Automatic temperature compensation for best accuracy under fluctuating temperatures
Meters automatically calculate and display electrode slope
Automatic message prompts help you easy to operate meter.
Expanded memory stores and recalls up to 99 data sets
USB Communication interface can be sent data to computer
During the ion mode, 2 to 5 points push-button calibration from low to high concentrations
Direct readout ion concentration simplifies the elaborate measurement process.
Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.

TECHNICAL SPECIFICATIONS

Ion Concentration Range-0.001~19999 ppm,mg/L,mol/L

Ion Concentration Accuracy +0.5% Full Scale (Monovalent),+1% Full
pH Range-2.000 to 20.000pH
pH Resolution -0.001pH
pH Accuracy-0.002pH
Calibration Points :5 points, NIST(pH4.00/6.86/9.18) or USA(pH4.01/7.00/10.01]

mV/ORP Range : 0 to +1999.9mV
mV/ORP Accuracy +0.2mV
Temperature Compensation: 0.0 to 100.0C, Manual or Automatic
Conductivity Range : 0 to 1.999,19.99,199.9,1999 S, 19.99, 200.0mS
Conductivity Accuracy : 0.5% F.S
Calibration Points : 1 point per range
Temperature Compensation : 0 to 50C, Manual or Automatic
Cell Constant : 0.1,1.0,10 adjustable
TDS Range : 0 to 100 ppt, Max.200 ppt
TDS Conversion Factor : 0.01 to 1.00, Default 0.67
Salinity Range : 0 to 50 ppt, 0.00 to 5.00%
Resistivity Range and Accuracy : 0 to 100M, W - 1%
Temperature Range : 0.0 to 100.0C,
Temperature Accuracy :+0.3C
Memory & Output : 99 data sets with date/ time stamping, USB
Weight -  1.75 kg
GOLD Member
Apr-17-25
 
Discover the UV-VIS Single Beam Spectrophotometer, your essential tool for precise measurements in the ultraviolet and visible spectrum. Analyze absorbance, transmittance, and concentration with ease. Ideal for research, education, and quality control.

Unique optical system, 1200 lines/mm grating.
The instrument has basic functions of photometric analysis and quantitative analysis.
It expands the applications, such as spectral scanning, kinetics, DNA/protein analysis, multi-wavelength test, etc. with PC software.
Store 200 test data and 100 standard curves;
Deuterium and Tungsten lamp can ON / OFF individually to increase the shelf life.
Large sample chamber can accommodate 5-100mm cuvettes.
Photometric Mode - T, A, C, E.
PC software available

Technical Specifications:

Model Name/Number
UV700

Type
UV-Vis Single Beam Spectrophotometer

Spectral Bandwidth 
2nm

Optical System
Single Beam, Grating 1200 lines/mm

Wavelength Range
190-1100nm

Wavelength Accuracy
+ 0.5 nm

Wavelength Repeatability
0.2 nm

Photometric Range 0-200%T, -0.3~3A, 0-9999C

Photometric Accuracy
+ 0.5%T


Stray Light
+ 0.1%T

Stability
+ 0.0002A/h @500nm

Noise
+ 0.001 A


Display
128 x 64 LCD

Light Source
Deuterium & Tungsten lamp

Cell Holder 
4 position 10mm cell holder

Output
RS232C

Power Supply
AC 220V/50Hz
GOLD Member
Apr-17-25
 
Precisely measure the absorbance of light in the visible spectrum with our high-performance visible spectrophotometer. Ideal for applications in chemistry, biology, and materials science.

4LCD Display.
RS232C Interface.
Measured values can be transferred to PC via RS232C port  for further analysis with software.
PC software available.
Wavelength can be set manually from the dial on the front panel.
Photometric Mode - T, A, C

Technical Specifications

Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Range - 330-1020 nm
Spectral Bandwidth - 5 nm
Wavelength Accuracy :-± 2nm
Wavelength Repeatability-  + 1nm
Photometric Accuracy - 0.5%T
Photometric Repeatability- + 0.2%T
Photometric Mode- T, A, C
Stray Light& Stability : 0.3%T & + 0.002A
Wavelength Setting : Manual
Display : 4" LCD
Light Source : Tungsten Lamp
Detector& Cell Holder-  Silicon Photodiode& 4 position 10mm cell holder
Powersupply -  AC 220V/50Hz
Packing Dimension -  (LxWxH) 520 x 450 x 320mm
Gross Weight  : 9kg
9693 Glass Ceramics Suppliers
Short on time? Let Glass Ceramics sellers contact you.