Ceramic commode, water closet, washbasin set, estern pan, turkish pan, full deep pan, paper holder, soap dish.
Refractory bricks,fire clay bricks, high alumina bricks, refractory material, Al2o3 % 70% bricks, fire creat super, refractory mortar,castable,insulation castable.
Ceramic & vitrified tiles, wash basin, clay pot, design tiles and bathroom accessories like wash basin, camod toilet.
Cabinet handle, door handle, door kit, knob, key stand, tower bolt.
Ceramic floor tiles, ceramic wall tiles, sanitary ware, vitrified tiles.
Ceramic wall tiles, vitrified tiles, porcelain tiles, sanitary ware, kitchen sink, laminate, wall putty, bathroom accessories, crepe cotton bandage, elastic cotton bandage, magnetic equipment.
Ceramic product just like digital wall tiles, parking tiles, vitrified tiles, marble, kota stone, granite.Trading
Live mud crab, squid whole, cuttlefish whole, silver pomfret.Exporter
Table tops, tiles, plates , trays , coasters, jewellery boxes, vases, figures of elephants etc.
Himalyan salt tiles, ceramic tile, porcelain tile.
Description This handy air sampler is portable and operates on both a mains power source and a rechargeable battery. For the purpose of monitoring air quality, this is helpful for gathering air samples. This is the best monitoring tool for indoor air quality. It includes a pump, a digital timer, a rotameter (05 LPM), and a flow controller with space for storage sampling equipment in a small stainless steel box. uses a rechargeable lead acid battery from SMP. When ingested, chemical compounds that are disseminated in the office environment as gases, vapours, and aerosols may have a variety of harmful health impacts. To assess the quantities of contaminants, the Handy Sampler is employed. Uses include the identification of air contaminants such dust, acid mist, ammonia, H2S, and free chlorine. the evaluation of individual exposures. the general background levels to be discovered. to assess the success of the control. to determine STEL and TWA values. Analytical Sampling Devices: The type of contaminant will determine which analytical procedures are used. FILTER PAPER HOLDER FOR DUST MONITORING - The gravimetric method may be used to measure dust. if it contains metals or compounds made of them. The Atomic AbsorbtionSpectophotometer can be used to analyse it. IMPINGERS FOR GAS & VAPOURS ANALYSIS OF ORGANIC GAS SUCH SO2, NOX, ETC. It uses the titrmetric or spectrophotometric method.
Smoke Visibility Tester: Smoke Detection The test device is comprised of a plywood chamber with an inner side painted with heat-resistant paint and a hole in the ceiling that allows a light metre cell to be held while being tested. The chamber's bottom has a hole that lines up with the hole in the ceiling. The bottom hole has a clear glass bulb installed in it. A hole is present on the chamber's left side, and an exhaust fan has been mounted there. A hole on the right side allows air to circulate when smoke is being expelled into the chamber. A hinged door with a transparent glass pane is on the front of the chamber. The right-side and left-side holes of the chamber each have shutters. An electronics regulator installed in the instrument panel is used to control the LUX of the bulb. The black drape covered the front glass window and the hole in the ceiling. On the section stand, the chamber was mounted. The device comes with a LUX metre for measuring the LUX of the light. The device also comes with a stainless steel plate and an aluminium silicate plate. A stainless steel specimen frame with provisions to hold the specimen and slide the specimen frame is slanted at a 20�° angle to the vertical. On the chamber's bottom, a burner is fixed at a 45-degree angle. For the purpose of adjusting the gas supply, a flow metre, pressure gauge, and pressure regulator are installed on the section frame. For long-lasting corrosion resistance, all the pieces have been coated or polished. No gas will be included with the instrument from our end.
ASTM D2863 Oxygen Index Oxygen Index: Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of PlasticsThe purpose of ASTM D2863 is to establish the lowest oxygen concentration in an oxygen/nitrogen combination necessary to sustain a flame burn on a plastic specimen. Real end use circumstances are not correlated. The test sample is placed vertically in a glass chimney, and a flow of oxygen and nitrogen is created there by starting at the bottom of the chimney. The test sample's top edge is lighted, and when the oxygen concentration in the flow falls, the flame eventually goes out. Specimen dimensions: Depending on the kind of material being tested, there are six requirements for the test specimen.
Aluminum, building materials, aluminium handles, aluminium door fitings, aluminium hinges, aluminium towerbolts, aluminium door stopper, aluminium locks, sanitary ware, curtain rods, curtain rounds, aluminium channels, aluminium window stay,.
Laboratory equipment, scientific apparatus, glassware, plasticware.
Thermometers, measuring instruments, chemicals, glassware, plasticware for lab or medical use.
Medical Disposable, Digital Tablet Hardness Tester, Sterilisation Reels, ETO Reel, Biological Indicators, Bowie Dick Test Pack, Chemical Indicators, SMS wrapping sheets, Under pads.
Science equipment, lab goods, chemicals, medical goods, glasswares, microscopes.
Laboratory filter paper, hydrometer & thermometer, silica, porcelain, platinum, nickel, aluminum & graphite ware, surgical disposable items, glassware, plastic wares & teflon ware, metal ware, micro slides & cover slip.
Scientific & laboratory equipments, disposable & surgical items, glassware.