Control transformer is the most used device in the industrial applications to take a high control on the voltage output. Trutech Products is the highly advanced Control Transformer Manufacturers in the array for catering the global industry with the highly efficient range of the products. All the products we manufacture are passed through various quality checks to ensure the best that you deserve. Feel free to write us back to know more about our range.
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
We are regular suppliers for all kind of plastic and metal and we ship to any destination port worldwide on CIF basis. interested buyers should contact us for more details and quotes
If the secondary voltage of the Transformer is a high voltage, it is called as Power Transformer. Makpower supplies power transformers which transform energy from higher voltage levels and to distribute this energy to lower voltage substations or directly to large industrial consumers.
200 Amp 3 ph Motorized Control Digital Variable Voltage Auto Transformer [Oil Immersed] [HSN CODE: 85044029] [Make: POWERSELECT] Technical Specification: Model: PS200A3POEM470V Rated Power: 150 KVA Input Voltage: 415 V AC 3phase�?�¸ (L - L), �?�±5% 50 / 60 Hz 4 wire / 3 wire No Load Current: Less than 1% of rated unit Output Voltage: 0 - 470 V AC 3Phase�?�¸, (L - L) �?�±10% 4 wire / 3 wire Output Current @470V: 0 - 200 Amp per phase max Variac Oil Qty: 250 L (Approx. +- 10 L) Recommended IS335 Reference Standard: IEC 61378-1 & IS 5142 : 1969 Voltage Variation: Motorized Operation with 10 kg torque AC Synchronous Servo Motor Servo Motor: 10 Kg torque AC Synchronous Servo Motor 220 V AC 1 ph. (Make: PowerSelect) Coil Construction: 1 Coils used in per phase of 200 Amp each rating Total Coils: 3 Coils used in unit each coil rating max 200 Amp Current Transformer: 3 nos. 200/5 Accuracy class 0.5% Protection: 3 pole MCCB on Primary line (Make: L&T) Enclosure IP Rating: IEC 60529, IP50 (Sheet Steel) with powder coated paint (Color: Siemens Gray) Connection Terminals: DMC molded bar insulators terminal Oil Drain: Oil Drain valve tap bottom of tank front sided Oil Level: Oil level indication front of tank with glass view Earth Terminals: Ground / earth terminals provided back sided Winding Wire: IS 12444, ASTM B-49 Pure Copper DCC wire Core Type, Grade of lamination: CRGO Laminated Core 30ZH100 Load : balanced load Service: Indoor Application Variac Dimension (LxBxH) and Wt (Kg): 24 x 38 x 60 (Approx) Net Wt: 450 Kg (Approx.) Gross Weight: 550 kg
Sub Merged Arc melting furnace transformers are manufactured in 3 phase system upto 12.5 MVA and Bank of 3 nos, single phase, transformers for higher than 12.5 MVA transformers.
ALL KIND OF TRANFORMERS
This static piece of apparatus improves efficiency and also reduces losses during run time. We provide best in class Power transformer which range from 33 KV to 200 KV voltage class and average rating starts from 200MVA onwards. We strictly adhere to international standards and certifications backed with GMP and best in class service provider.
And this domestic and LT static provides precise reading (voltage) at either step down or step up mode. It is made possible with stringent GMP backed with years of experience. We provide best in class Distribution transformer which range from 11KV to 22KV voltage class and average rating starts from 10kVA onwards. We strictly adhere to international standards and certifications backed with GMP and best in class service provider.
We supply all the types of Transformers per the desired applications and also maintain the international quality standards
The range of toroidal transformers can vary in terms of power capacity, voltage, and mounting style: Power capacity: Standard toroidal isolation transformers can range from 100 to 5,000 VA. Voltage: Dual primaries can be configured for 120 V or 240 V operation. Dual secondaries can range from 2 to 12 V windings to 2 to 120 V windings. Mounting style: Standard mounting for sizes up to 5000 VA is with a single metal centering washer and mounting screw or bolt. Other mounting methods include PCB mounting, DIN rail mounting, and resin center potting with brass inserts. Toroidal transformers are known for their high efficiency, typically ranging from 95% to 99%. This high efficiency is due to their near-ideal design, which effectively contains the magnetic flux within the windings, eliminating leakage flux.
They are used in electrical applications when the frequency ranges between 2 MHz to several hundred MHz and are suitable for inductors above 70 Mhz. 3. Sand Dust: These are high-frequency Choke Coils ideally used with ferrites only.
output voltages ranging from 012V, 5Amp R-core Transformers are manufactured using the unique rectangular core with round cross section known as R-core. The special feature of this transformer is that the core is gap less and continuous. The winding is done on special round bobbins on two parallel legs of the core. Design The core is continuous and gapless, with two balanced windings on either side. The winding is done on special round bobbins on the two parallel legs of the core. Size R-core transformers are smaller and have a lower profile than E-I core transformers of the same capacity. Temperature rise R-core transformers have a lower temperature rise due to the round cross sectional area and tapered slitting. Noise R-core transformers have low noise due to the balanced winding and low flux leakage. This makes them suitable for use in noise sensitive equipments. Leakage flux R-core transformers have a leakage flux that is about 1/10th of conventional transformers. This allows the transformer to be placed close to critical electronic components.
An EI transformer is a type of transformer with a core made of thin electrical steel sheets that are stacked to form the letters E and I. The primary and secondary windings are wound on bobbins, which are then placed on spindles to apply the windings.
Distribution board is also called a panel board, breaker panel, electric panel or DB box. Its main function is to divide the electrical power evenly among all the electrical devices. The primary functions also include power generation, transmission and distribution.
TRANSFORMER
TRANSFORMER
Transformer To IS: 2026-1977 RATED KVA -500 TYPE OF COOLING - ONAN RATED HV V-11000 OIL TEMP.RISE deg.c - 50 VOLTAGE LV V-433 Wdg.TEMP.RISE deg.c - 55 RATED HV A-26 IMPED.VOLT. % - 3.883 CURRENT LV A-667 VOLUME OF OIL 1. - 525 PHASES - 3 MASS OF OIL KG - 450 FREQUENCY HZ- 50 UNTANKING MASS KG - 1040 ONN.SYMBOL - Dyn11 TOTAL MASS KG - 2500 YEAR OF MFG. - 1999 MAKER'S SERIAL NO. - 905 CUSTOMER'S REF. - PO.NO.-PP-PVD/287 ORD-ASM Dt-02/02/99 INSULATION LEVEL - Li 75 AC 28
Electrical transformer.