Gas generator, gas equipment, analytical equipment, consumables, hplc consumables etc.
Sound proof canopy accessories, DG part, sound acoustic accessories.
Diesel generator.
Generator, canopy, amf panel, battery, gel earthing (2 x 80, 3 x 80).D.G. Set repairing ,services, AMC, installation, gel earthing
SMPS, power supplies.
GBCDG11AF006SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF006SACH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1 - 0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF006SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF006SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 792 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF008SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF008SACH Relay type CDG 11 Special Case size 1D V 10T Application O/C Current setting 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 771 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF009SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF009SACH Relay type CDG 11 Special Case size 1D V 10T Application E/F Current setting 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 793 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
GBCDG11AF011SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF011SA(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 - 10 Amps. Name Plate RFG9125674 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
Dpc al & cu wire second hand transformers & electrical equipment.
Petcoke fired CFBC boiler power plant, power generation, power plant.
Electrical Goods.
Van De Graaff Generator.
All Engine and Transmission.
Power supply.
PSA nitrogen gas generators, oxygen generators and hydrogen generators.Manufacturing
Power generators.Manufacturing
Electric power generators.
Electromagnetic flow meter, ultrasonic flow meter, ultrasonic heat flow meter, btu meter, ultrasonic level meter.