GBCDG11AF006SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF006SACH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1 - 0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF006SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF006SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 792 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF008SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF008SACH Relay type CDG 11 Special Case size 1D V 10T Application O/C Current setting 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 771 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF009SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF009SACH Relay type CDG 11 Special Case size 1D V 10T Application E/F Current setting 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 793 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
GBCDG11AF011SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF011SA(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 - 10 Amps. Name Plate RFG9125674 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
Transmission lines are the connectors running between generating stations and distribution stations. Transmission lines carry high voltages from the generating stations to primary transmission stations, secondary transmission stations, primary distribution stations, and secondary distribution stations
BRAND PRODUCT CODE DESCRIPTION HSN CODE Moduler Box 21780 1 or 2 Module 85389000 Moduler Box 21452 3 Module 85389000 Moduler Box 21791 4 Module 85389000 Moduler Box 21463 6 Module 85389000 Moduler Box 30453 8 or 9 Module Horizontal 85389000 Moduler Box 21474 8 Module Rectangular 85389000 Moduler Box 21485 12 Module 85389000 Moduler Box 21736 16 Module 85389000 Moduler Box 21758 18 Module 85389000
Jing Young Guy clamp is mainly used on the communication line. It used together with the stay wire and an- chor rod to make the pole stable. When the stay wire goes across the anchor rod, the 3 bolt clamp bites the end of the stay wire to prevent the stay wire from creeping down TYPE - JY- 5055 Length - 1 15/16 Width - 1 9/16" Product Finish - Galvanized, ASTM A-153 Material - Steel Note - One bolt 1/2" guy clamp Weight - 0.6 lbs Accommodates - 1/4" to 7/16
Jing Young Guy clamp is mainly used on the communication line. It used together with the stay wire and an- chor rod to make the pole stable. When the stay wire goes across the anchor rod, the 3 bolt clamp bites the end of the stay wire to prevent the stay wire from creeping down. TYPE - JY-Strait 7901 Length - 2 1/2 Product Finish - Galvanized, ASTM A-153 Material - Steel Note - 5/8" Mounting Bolt Weight - 0.66 lbs Accommodates - 1/4" to 7/16"
1. Catalog no. - JY-G0206 Weight/ 100pcs - 43 Standard package Qty/ - 60 2 .Catalog no - JY-G0206- 01 Weight/ 100pcs - Press steel Standard package Qty/- 60
Jing Young Guy clamp is mainly used on the communication line. It used together with the stay wire and an- chor rod to make the pole stable. When the stay wire goes across the anchor rod, the 3 bolt clamp bites the end of the stay wire to prevent the stay wire from creeping down. TYPE - JY-Angled 7902L Length - 7" (178 mm) Product Finish - Galvanized, ASTM A-153 Material - Steel Note - 5/8" Mounting Bolt Weight - 2 lbs Accommodates - 1/4" to 7/16
Jing Young Guy clamp is mainly used on the communication line. It used together with the stay wire and an- chor rod to make the pole stable. When the stay wire goes across the anchor rod, the 3 bolt clamp bites the end of the stay wire to prevent the stay wire from creeping down 1. TYPE - JY-Strait 7903 Length - 5 3/4" Product Finish - Galvanized, ASTM A-153 Material - Steel Note - 5/8" Mounting Bolt Weight - 1.83 lbs Accommodates - 1/4" to 7/16 2. TYPE - JY-Strait 7903L Length - 5 3/4" Product Finish - Galvanized, ASTM A-153 Material - Steel Note - 5/8" Mounting Bolt Weight - 1.57 lbs Accommodates - 1/4" to 7/16 3. TYPE - JY-Angled 7904 Length - 5 3/4" Product Finish - Galvanized, ASTM A-153 Material - Steel Note - 3/4" Mounting Bolt Weight - 1.74 lbs Accommodates - 1/4" to 7/16
1. Catalog no. - JY-G0206 Weight/ 100pcs - 43 package Qty/ - 60 2 .Catalog no. - JY-G0206- 01 Weight/ 100pcs - 50
Product Details : The Transformer used in the power supply unit is manufactured as per the UL norms. The transformer will be potted/sealed in an enclosure using Epoxy (a mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer's needs a circuit breaker of 25A is provided for circuit protection. Technical Details : Wattage - 75w to 1200w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages as per customer requirements Insulation class F, H Max. regulation 10% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
Aluminium die casting components ........for textile and plastic industries
Aluminium die casting components ........for textile and plastic industries
Aluminium die casting components ........for textile and plastic industries
Input AC Voltage: 90V - 264V Output Voltage: DC 12V 2Amp High Quality And Genuine Products DC Power Supply (SMPS) Used in CCTV Camera And Computer Protections Overload And Over Voltage 100 Percentage Full Load Burn in Test Material Metal Case And Aluminum Base
Input Voltage: AC 110V - 220V Output Voltage: DC 24V 40Amp Output Wattage: DC 1000W Used In LED Strip Light And CCTV Camera Good Quality Genuine Products
Mfrs. of Led Driver, Led Controller, SMPS Power Supplies for CCTV Camera / Security Systems, SwitchingPower Supplies, Battery Charger, DC/DC Converter, Transformer, Medical Power Supply, Switching Adaptors, Solar Products, E- Bike Charger, E. Rickshaw Charger, Car Inverter, UPS & Inverter, Cvt.