Product Details: Number of Reactions(Preps)/Kit 25 T Brand Premier Result Time (Rapid Kits) 20 - 30 Min Certified WHO Approved CAT No; PI19FRC25 First Response Malaria Ag. P.f. / P.v. Card Tests intended to be performed by trained users (In either laboratory or point of care settings) as qualitative screening in vitro diagnostic test for detection of P. falciparum and P. vivax. Product specifications : Sensitivity - 100% Specificity -100% Rapid Result time within 20 - 30 Minutes. Detects P. falciparum and P. vivax. Storage at 1 40 C. Specimen Type- Whole Blood
Product Details: Number of Reactions(Preps)/Kit 25 T Brand Premier Result Time (Rapid Kits) 20 - 30 Min Certified WHO Aproved CAT No; PI16FRC25 First Response Malaria Ag. pLDH/HRP2 Combo Card Test is intended to be performed by trained users (In either laboratory or point of care settings) as qualitative screening test for detection of P.falciparum, P. vivax, P. ovale and P. malariae. 100% - Specificity 100% - Sensitivity Rapid Result time within 20 - 30 Minutes. Storage at 1 40 C. Detects P.falciparum, P. vivax, P. ovale and P. malariae. Specimen - Whole Blood
CFX Opus 96 Real-Time PCR Instrument 0.2 mL, 96 Wells Product Details: Brand BioRad Model Name/Number CFX Opus 96 Sample Capacity/Format 96 wells Multiplex analysis Up to 5 targets per well Dimensions (W x D x H), cm/in 33x56x36 / 13x22x14 Cat No 12011319 Description CFX Opus is the newest real-time PCR system in our robust CFX Family. The CFX Opus 96 Real-Time PCR System can analyze 96 wells and offers a number of new features: More uniform thermal performance Expanded connectivity Wi-Fi, ethernet, and USB Cloud connectivity: Operate CFX Opus on our BR.io cloud platform or with desktop CFX Maestro Software Network storage drive access for excellent data management Shuttle optical system yields consistent optical measurements across your sample plate SpecificationsThermal CyclerMaximum ramp rate, C/sec5Average ramp rate, C/sec3.3Heating and cooling methodPeltierLid, C30 110 Temperature Range, C4 100Accuracy, C ±0.2 of programmed target at 90 C Uniformity, C ±0.3 well-to-well after 10 sec of arrival at targetGradientOperational range, C30 100Programmable span, C1 24Optical DetectionExcitation6 filtered LEDs Detection6 filtered photodiodes Range of excitation wavelengths, nm450 684 Range of emission wavelengths, nm510 730Sensitivity Detects 1 copy of target sequence in human genomic DNADynamic range10 orders of magnitudeScan TimeAll channels, sec12 FAM/SYBR Green only, sec3SoftwareOperating systemWindows 10Multiplex analysisUp to 5 targets per wellSystemSample capacity, wells96 Sample size, µl150 (10 50 recommended) Communication interface USB 2.0 Electrical approvalsIEC, CE Dimensions (W x D x H), cm/in33x56x36 / 13x22x14Weight, kg/lb22/48
Product Details: Number of Reactions(Preps)/Kit 22 Test Brand Abbott Usage/Application Hospital Cat. No 710-000 Abbott BinaxNOW S. pneumoniae Antigen Card provides accurate, rapid identification of S. pneumoniae antigen in patients with pneumococcal pneumonia and pneumococcal meningitis with an easy-to-use technology, aiding physicians in providing rapid, focused therapy. Time to Result: 15 minutes Performance data: Urine Sensitivity/Specificity 86% / 94% CSF Sensitivity/Specificity 97% / 99% Ordering Information Cat No. Description Specimen Pack size 710000 Streptococcus Urine, CSF 22 Tests Pneumoniae Ag card
Product Details: Brand Roche Result Time (Rapid Kits) 15 min CAT No : 11621947196 Qualitative detection of troponin in anticoagulated (EDTA or heparin) venous whole blood Reaction time: 15 min. Positive result from a threshold (cut-off) of 100 ng/L Storage at 2 to 8 C Test can be used immediately after removal from the refrigerator Storage for 4 weeks at room temperature (15 to 25 C) Roche TROP T sensitive rapid assay is available in 5 and 10 pack sizes Content: 5 disposable test strips (individually sealed) 5 pipettes (150 L) disposable labels 1 package insert
Product Details: Brand SD Country of Origin Made in India Specimen Serum Shelf Life 24 Months Temperature Storage 30 Degree Celsius Sensitivity 97.6% Specificity 98.0% H.Pylori Helicobacter pylori (H.pylori) is a spiral shaped bacterium and is found in the gastric mucous layer or adherent to epithelial lining of the stomach. H.pylori causes more than 90% of duodenal ulcers and up to 80% of gastric ulcers. Approximately two thirds of the world's population is infected with H.pylori. The immuno- chronomatographic techinques for the detection of antibodies specific to H.pylori has substantially resolved these problems. General Information: SD BIOLINE H.pylori test is a rapid test for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA etc) specific to Helicobacter pylori in human serum plasma or whole blood. Detection of all isotype (IgG, IgM, IgA) antibodies against H.pylori High Accuracy Sensitivity: 95.9%, Specificity: 89.6% Specimen: Serum. Plasma, Whole blood Material provided with this kit are as follows: SD BIOLINE H.pylori test device multi-device Assay diluent
Product Details: Number of Reactions(Preps)/Kit 40 Brand Abon Result Time (Rapid Kits) 15 mins The Syphilis Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema Pallidum (TP) in whole blood, serum or plasma to aid in the diagnosis of Syphilis.
Product Details: Number of Reactions(Preps)/Kit 25 T Brand Abbott Result Time (Rapid Kits) 15-20 Min Cat. No 11FK50 Biolineâ?¢ DENGUE NS1 AgTEST FOR EARLY CLINICAL PHASE OF DENGUE INFECTION Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood. Product not available in all countries. Please check with your local sales representative regarding availability in your area. Benefits: Diagnosis of early acute dengue infection by detecting dengue NS1 antigen Dengue NS1 antigen can be detected from 1 day after onset of fever Specimen : Serum, plasma or whole blood (100l) Test result : 15~20 minutes Specification: Sensitivity 92.4%, Specificity 98.4%
Product Details: Number of Reactions(Preps)/Kit 100 Brand Alere Usage/Application Hospital Result Time (Rapid Kits) 15 mins The irst and only FDA approved rapid point-of-care test that simultaneously andseparately detects HIV-1/2 antibodies and free HIV-1 p24 antigen on a single test strip.Determine Combo Pack Size : 100 Test Brand : 100 Test
Product Details: Number of Reactions(Preps)/Kit 22T Brand Abbott Result Time (Rapid Kits) 15 Min Cat. No 852-000 BinaxNOW Legionella Urinary Antigen Card is a rapid assay for the qualitative detection of Legionella pneumophila serogroup 1 antigen in urine samples from patients with symptoms of pneumonia. It is intended to aid in the presumptive diagnosis of Legionnaires disease caused by L. pneumophila serogroup 1 in conjunction with culture and other methods. Sample Type: Urine Time to Result: 15 minutes Kit Size: 22 tests Performance Data: Sensitivity/Specificity: 95%/95%
Product Details: Brand Abbott ICMR Approved Yes Test Method Antigen Test Result Time (Rapid Kits) 15 min Packaging Size 25 Test Kits/Box Cat. No 41FK10 Panbio COVID-19 Ag Rapid Test Device is an in vitro diagnostic rapidtest for the qualitative detection of SARS-CoV-2 antigen (Ag) in humannasopharyngeal swab specimens from individuals who meet COVID-19clinical and / or epidemiological criteria. Panbio COVID-19 Ag RapidTest Device is for professional use only and is intended to be used asan aid in the diagnosis of SARS-CoV-2 infection
Product Details: Brand : ABBOTT ICMR Approved : Yes Result Time (Rapid Kits) : 10-15 mins Packaging Size: 1 T CAT No : 41FK51 Certified CE certified The Panbio COVID-19 Antigen Self-Test is a single-use, in vitro (outside the body) visually read rapid immunoassay that uses a human nasal swab specimen for the qualitative detection of nucleocapsid protein SARS-CoV-2 antigen. The test can determine if you have an active COVID-19 infection and you will know your test results in just 15 minutes Only Proven High-Accuracy Self-Test in India In clinical evaluations with self-test users, the Panbio COVID-19 Antigen Self-Test correctly identified 100% of negative samples and 95.2% of Positive Samples Pregnancy had no impact on the performance of the test.
Product Details: Brand : Premier medicals Result Time (Rapid Kits) : 15 min Sample Type : Nasal Swab Packaging Size : 25 Test Kits/Box CAT No : SS03P25 Certified WHO Approved Sure Status COVID-19 Antigen Card Test is a rapid chromatographic immunoassay for the qualitative detection of specific antigens to SARS-CoV-2 present in human nasopharynx
Product Details: Number of Reactions(Preps)/Kit ; 25 Brand : Cellex Test Method : (SARS-CoV-2) IgM/IgG Rapid Antibody Result Time (Rapid Kits) 30 minutes Time To Result 15 mins Cat. No : 5513C COVID-19 serology test.Cellex qSARS-CoV-2 IgG/IgM Rapid Test.qSARS-CoV-2 IgG/IgM Rapid Test Cassette.FDA Grants Emergency Authorization for First Rapid Antibody Test for COVID-19
AbChek (SARS-CoV-2) IGM/IGG Corona Rapid Antibody Test Kit Product Details: Number of Reactions(Preps)/Kit : 50 Brand : AbChek ICMR(Govt) Approved : Yes Test Method : (SARS-CoV-2) IgM/IgG Rapid Antibody Result Time (Rapid Kits) : 5-10 minutes Sample Type : Blood Type : Rapid Test Kit Sensitivity : 98 Packaging Size : 50 Tests/ Box Country of Origin : Made in India Corona viruses are enveloped RNA viruses that are distributed broadly among humans, birds and other mammals, that cause respiratory, enteric, hepatic, and neurologic disease. SPECIFICATIONS: Whole blood/serum/plasma may be used for testing. Results available in only 15 minutes. Easy to use. Result can be read visually. No need for an analyser. Cost effective method for assisting in screening COVID-19 disease. Additional Information: Item Code: RapidTestcov19 Production Capacity: 100000 Delivery Time: 10 days Packaging Details: Carton Box
Product Details: Number of Reactions(Preps)/Kit ; 2 Brand ; iHEALTH Test Method : Antigen Test Result Time (Rapid Kits) : 15mins Sample Type : Nasal Swab Cat. No : ICO-3000 iHealth COVID-19 Antigen Rapid Test is the simplest way to detect SARS-CoV-2 nucleocapsid protein antigen. It only takes 4 steps and 15 minutes to complete the test. The test is also non-invasive. You won't need to collect a sample from deep in your nasal cavity to get accurate results.
Product Details: Brand : Abbott ICMR Approved ; Yes Sample Type : Nasal Swab Packaging Size : 25 Test Kits/Box Cat. No: 195000 The BinaxNOWTM COVID-19 Ag Card is a lateral flow immunoassay intended for the qualitative detection of nucleocapsid protein antigen from SARS-CoV-2 in direct anterior nasal (nares) swabs from individuals suspected of COVID-19 by their healthcare provider within the first seven days of symptom onset
Product Details: Number of Reactions(Preps)/Kit : 25 Test Brand : GenBody Sample Type : Nasal Swab Storage Temperature : -2 to - 30 C Cat. No : CVIFG040-1 Genbody Influenza/ Covid - 19 Ag Triple, Rapid immuno-diagnosis of influenza A, B & SARS-CoV Single test for 3 parameters: antigen test of influenza A,B & SARS-CoV-2 Easy to use, Simple Procedure, Quick resulting and high Accuracy. Production information: 1.Specimen: nasopharyngeal swab or Viral transport medium (VTM) 2.No Cross-reaction with 27 kinds of other respiratory viruses. 3.No interference with 23 kinds of interfering substances. 4.Limit of detection (LoD):1.89x10 HA units/mL for influenza A, 4.1 x 10 HA units/ mL for influenza B, 1.78x10 TCID/mL for SARS-CoV-2. 5.Detection of SARS-CoV-2 Varients: alpha,beta,gamma, delta, omicron & stealth omicron.
ThermoFisher Scientific Accula System Rapid & Reliable RT-PCR Test for Corona in 30mins Product Details: Number of Reactions(Preps)/Kit : 25 Brand : Thermo Test Method : (SARS-CoV-2) RT-PCR Sample Type : Nasal Swab Test Time 30 min The Accula System from Thermo Fisher Scientific is a rapid diagnostic platform that combines the accuracy of RT-PCR with the simplicity, convenience, and procedural familiarity of traditional rapid immunoassays. The Acculaâ?¢ SARS-CoV-2 Test has received an Emergency Use Authorization (EUA) from the FDA for the detection of SARS-CoV-2 in Clinical Laboratory Improvement Amendments (CLIA) waived environments. Designed for use with the palm-sized Accula Dock, the Accula SARS-CoV-2 Test provides reliable, qualitative results in approximately 30 minutes
Hi-PCR Coronavirus (COVID-19) Multiplex Probe PCR Kit Product Details: Number of Reactions(Preps)/Kit : 100 Rxns Per Box Brand : HIMEDIA Storage Temperature : -10 to -20 C Detection : Probe Based Target : E, N and RdRp gene. Cat No : MBPCR243 Description A ready to use Rt-PCR Kit for Detection of Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19). SARS-CoV-2 is a coronavirus, subgenus Sarbecovirus, 150-200nm in diameter with a genome size of about 30 Used For A ready to use Rt-PCR Kit for Detection of Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19).