All type of wires, cables, conductors for power supply, distribution, control, telecommunication, computer network, instrumentation application and appliances.Marketing of any light engineering products, consumer durables in Indian market on commission basis.
Copper cathodes.
ACSR / AAC / AAAC conductors.
Wires, cables, copper conductor, road lighting, aluminium conductor, luminaire.
Insulator, ceramic insulator, LV insulators, HV insulator, MV insulator, suspension insulator, pin insulator..
Electrical insulators.
Electric Motor..
Analog and digital panel meters.
Harma e8 oil, herbal seeds, capacitors, all medicated and electrical products.
Permanent magnet generator, wind alternator, low speed alternator.
Electrical Goods 3pin Top Holder Mcb Mcb Box.
Pvc electrical conduit pipes.
Switches, holders, 2 pin top , 3 pin top .
Reconditon Vcb Panel ,Spare Parts Of Vcb Ocb Panels, Rmu. Outdoor Vcbs, Vaccum Interrupters Etc.
Polypropylene bags for sugar and flour, supply of confectionary items from euope, electronics, electrical, crockery, car accessories from china, hong kong and taiwan.
3-ply-face-mask, hand sanitizer, electronic components.
Electrical and engineering products, textiles, safety equipments, sports items, educational items.
5-2 AL Aluminum conductor - AAC For this conductor, the applicable paragraphs of article 4 are: 4.2 & 4.4 The sizes of conductor required are as follows: 95 mm2 19/2.5 mm & 2000 m + 2% per drum. 70 mm2 19/2.1 mm & 3000 m + 2% per drum. 50 mm2 19/1.8 mm & 3000 m + 2% per drum. 35 mm2 7/2.5 mm & 3000 m + 2% per drum.
System voltage 415 V +/- 10%, 3 Phase, 4 wire AC 2. Frequency 50 Hz +/- 3% 3. Fault level Shall be designed for fault level of 50 KA for 1 sec 4. Grounding Solidly grounded neutral system 5. Insulation level a) Power circuit b) Control circuit 2.5 KV / 1 minute 1.5 KV / 1 minute 6. Main bus bars Shall be designed to carry continuous current rating of 1.2 times of incomer ACB unitâ??s continuous current rating and STC of 50 kA for 1 sec. Temperature rise, short circuit design shall be as per IS 8623. Max. Current density for the material of bus bar shall be as follows: Copper: 1.6 Amp/Sq.mm Aluminum: 0.8 Amp/Sq.mm (For Sl. No. 12 PCC)
Conductor is to be sized to carry maximum earth fault current of system at point of application with final conductor temperature not exceeding 160 deg. C (320 deg. F) for at least 5 seconds. Main earthing conductors are to be minimum 120 mm2 or as otherwise required by the particular Section of the Specification.