12v. Dc. Magnetic float switches... For every kind of weather. 4'long. 30gm weight
Can conrol upto 8 lights and 2 fans with a single infra red based remote system, invertor compatible, software based technolgy with non volatile memory.
Modular switches, modular frames, remote control solutions/switches for lights & fans.
Protocontrol manufactures more than 1700 varieties of proximity switches under one roof. We offer solutions to your sensing needs. 10 numbers , 5 kg
Protocontrol offers complete solutions to level sensing needs. We offer level switches and transmitters for solids, liquids and granules. From simple float type level switch to advanced radar type level transmitter is available. 1 no 5 kg
Temperature rise test panel for domestic switch Specifications Input supply : 230v ac + / - 10% , 50 hz single phase with mcb protection. Output : current source 0 to 50 a max Digital voltmeter : 3-1/2 digit 0 to 300v Voltage drop indicator with range selector. Digital temperature indicator with 12 channels. Current controller for maintaining the output current at pre-set value. Ct range selector for accurate measurements. Description The test panel is made to suit the specification as mentioned in is : 3854 of 1997 for temperature rise test. The test panel broadly comprises of : 1. Ac constant current source ( true rms ) for 50 amps max / 5v. 2. Universal servo controller, for controlling the output current with the help of motorised variac Assembly. 3. Digital ac voltmeter to read the primary voltage of the power transformer. It helps to eliminate the Possibility of hunting of motor with the help of primary tap selector switch. 4. Digital temperature indicator controller - 12 channels - with thermocouples, to read the temperature rise At different parts of the switches. 5. Digital ac voltmeter with terminals and three ranges - 0.2, 2.0 & 20 v to measure the voltage drop Across the switch terminals while passing the specific current. 6. Range selector switch for ct to measure more accurately the current for lower as well as higher range. 7. Push buttons for test on / off with output indicating lamps. 8. Mains on mcb 2p / 10 a.
Part No : 1801
Part No : 1802
Part No : 1803
Part No : 1804
Nomral Touch, Automation Switch
Single Phase to Single Phase Midpoint Cycloconverter Trainer - BRAND - VIJAYANTA, INDIA To Study of Single Phase to Single Phase Midpoint Cycloconverter Trainer, Model: SPCC â?? 100 The set â?? up Consists : Four SCRs, one transformer, one midpoint tapped inductor Logic controlled firing control circuit. A selector switch is provided to obtain �½, 1/3, �¼ of input frequency . Opto isolators are used for coupling of logic signals with the thyristors. Test points are given at different places for observations. A resistive load and an inductive load in form of small motor is provided.
Study of Single Phase Dual Bridge Converter - BRAND - VIJAYANTA, INDIA 1. Study of Single Phase Dual Bridge Converter, Model: SPDC 301
Study of Single Phase SCR Half Bridge Converter - BRAND - VIJAYANTA, INDIA 1. Study of Single Phase SCR Half Bridge Converter, Model: SPHB 102
A reliable source of abb, allen bradley, siemens, L & T switchgear products, controllers, contactors, relays, plc, transformer, motors & pannel boards, temperature/ pressure sensors available
The products so displayed are modular plates and switches and sockets used for home and office use.
Manufacturer & Exporter of Side Mounted Magnetic Level Switch. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. We have been widely appreciated by the esteemed customers for our ability to offer a quality range of Side Mounted Magnetic Level Switch. The range is widespread and meets various industry applications catering to all type of operating conditions. The switches can have miniature floats, vertical or horizontal mounting operating in single and multiple liquid levels. Applications: High / Low level Alarm Automatic Pump/Valve control Elimination of tank over flow Enhances pump safety against dry running Features: Temperature: 0-3000C Pressure: 20 KG/CM2 MOC: SS-304, SS-316, SS-316L, PP Details Required For Quotation: Nozzle Size On Which You Are Intending To Mount The Switch Material Of Construction Of Wetted Parts Service Specific Gravity Operating Pressure Operating Temperature Flange Details Housing Enclosure (Flame Proof/ Weather Proof)
Level Switch Being a patron focused organization, we are engaged in manufacturing and supplying best grade Level Switch. We manufacture a qualitative range of water meter that is manufactured using premium grades of raw material. It consists of inferential, multi jet, dry type water meter with magnetic drive and vacuum sealed register. Cable Type Balloon Level Switch We specialize in providing a range of Cable Type Balloon Level Switch that is appreciated for their optimum quality, durability and easy installation. Being the leaders in the industry, we present Cable Float Level Switches to our clients. They require minimum maintenance and are presented at the best rates in the industry. Applications: An Economical, Viable alternative for control in liquid levels Simple, Rugged & Reliable Range: up to 5 mtr. Switch rating: 10-14 AMP@ 230 VAC Material of Construction PVC suitable for most liquids Housing: Weatherproof to IP 66/68/ Flameproof - On request Details Required for Quotation: Tank height No of contacts Level Gauge We are an ISO 9001:2008 certified company involved in manufacturing, supply and exporter of Level Gauges in India. These are manufactured from state of the art technology and is in high demand from our valued buyers. Uses: Water Level Gauge Tank Level Gauge Oil Level Gauge Liquid Level Gauges
RF Level Switch Manufacturer & Exporter of RF Level Switch & RF type Level Switch. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. We specialize in manufacturing a wide range of RF Type Level Switch that vary from simple, single point, low cost level to specialized & complex level. The RF Level switch operates on the basis of RF absorption. The electronic unit generates a sinusoidal wave, applied to the electrode creating a field around it. Design Considerations: RF Type Level Sensors Switch have been designed taking into consideration characteristics and behavior of materials like Solids (in their granular from), Slurries and Liquids. Few important conditions are given below: Coating: Most materials have a common tendency to accumulate and coat over anything in contact like walls or any other part that protrudes inside the vessel. That happens by natural phenomena and can not be avoided completely. The Level Sensor must be unaffected by coating and accumulation of material on the sensing element or on side walls. RF Design: RF Principle based Level Sensors have been designed based on the considerations discussed and various other aspects. Flow star RF Level Sensors are highly reliable for use with materials that are conductive or non conductive, granular or slurries, fines to large particles and contaminated or pure liquids at varying temperatures and pressures. Description: Flow star RF Level Switch series FERF 200 comprises of two parts, namely a Sensing Probe and an Electronic controller. The Sensing Probe has two parts, active section and shield section insulated from each other as shown in the diagram. A dust proof Probe Head is provided to cover the terminals of the Rf signal cable. Meaning hereby, the Probe contains no electronics or any other sensitive element. The Electronic Controller separately housed in dust proof enclosure designed for outdoor duty and mounted at a convenient location. It contains the entire electronics, etc. and is connected through a coaxial cable to the Sensing Probe. Functions: Flow star RF Level Switch Series FERF200 Models work on Rf Principle. Independent but identical low power RF signals equal in frequency, phase, amplitude and wave shape generated in the Electronic Controller are provided to active and shield sections of the Sensing Probe, whereas, the reference ground of electronics is connected to the vessel shell The signal provided to the shield section is maintained constant by use of a compensating circuit in the Electronic Controller while the signal applied to the active section varies with change of media between probe and the vessel shell/wall
1 kv to 66 kv medium voltage switch gear products. As per requirrement