Applications:
Long distance telephone, catv, data communications.
Installations:
Installed in duct, self supporting (figure 8 self supporting or adss all dielectric self supporting) and direct
Burial (with armouring).
Construction:
The cable consists of a single tube containing 2 up to 24 fibers, which is filled with water-blocking gel. When the
Cable contains more than 12 fibers, they are divided in two groups. A colored thread identifies each group. Physical
Protection and tensile strength are provided by aramid yarn or fiberglass wound around the tube. Either pe or lszh
Jacket can be used. A ripcord is located under the jacket to facilitate jacket removal.
Technical parameters:
Maximum transmission distance: 6km (single mode); 0.3km (multimode)
Maximum pulling load: 1500n (short term installation); 900n (long term installation)
Maximum compressive load: 3000n (3.3mm loose tube diameter); 5000n (4.5mm loose tube diameter)
Twist (torsion length): 125 x overall diameter
Working temperature: -20íµ ~ +70íµ (pe sheath)
Storage temperature: -40íµ ~ +70íµ (pe sheath)
Product highlights:
Small diameter and light weight.
Through the control of the fiber exceed length which is the key technology in optical fiber manufacture, the fiber
Cable can achieve better pulling load and operating temperature.
Tube materials are water resistant and can sustain high tension. Being filled with special water-blocking gel, the
Tube can provide water protection for the fibers inside the tube.
Compact construction of the fiber cores can prevent the fiber to shrink back. This can sustain higher tensile stress
And achieve better flexibility.
íewide operating temperature range.
í= Applications:
Short and medium distance, indoor and protected environments. Offered as a riser, plenum, or general purpose cable,
it is used for interconnection of distribution boxes, or the distribution boxes and customer equipments, and between
floors.
í= Installations:
Installed along the wall, the roof, interlayer, canal and indoor.
í= Construction:
The cable contains 4 to 72 fibers individually buffered to 0.9 mm in a tight or semi tight construction and coded. The
cable structure depends on the number of fibers: The 4 to 12 fiber cables contain individual fibers without sub-units,In
the 16 to 72 fiber cables the fibers are grouped in the sub-units. In the 4 to 12 fiber cables, the individual fibers are
stranded and protected by aramid yarn and a PVC or LSZH jacket. In the 16 to 72 fiber cables, the fibers are grouped
into sub-units which are laid helically along the cable axis. Each sub-unit contains 4 to 6 fibers, aramid yarn and a
PVC or LSZH jacket. The 72 fiber cable consists of twelve sub-units, nine of them are stranded around a central
element made of 3 sub-units.
í=Technical Parameters:
íe Maximum Transmission Distance: 6km (Single Mode); 0.3km (Multimode)
íe Maximum Pulling Load: 100N(Short Term Installation);60N(Long Term Installation)
íe Minimum Bending Radius:
Short Term Installation: 20 x Overall Diameter
Long Term Installation: 10 x Overall Diameter (Non-Armoured);
20 x Overall Diameter (Armoured)
íe Twist (Torsion Length): 125 x Overall Diameter.
íe Working Temperature: -10íµ ~ +70íµ (PE sheath)
íe Storage Temperature: -20íµ ~ +70íµ (PE sheath)
í= Product Highlights:
íe Small diameter and light weight.
íe The high tension characteristics of the aramid yarn serving as strength member
can offer good stability in the transmission performance.
íe Compact and flexible construction are especially suitable for indoor installations.
íe Tight Buffer fibers are made from fiber rods with good linearity and low extruding output. By careful calibration of
the vacuum pumping equipment, the uniformity of the outer diameter of the tight buffer fibers can be easily achieved
with excellent strip ability.
íe LSZH jackets can be offered for indoor application for which flame retardancy is required.
íe Cutting edge production equipment, good quality materials and optimized process ensure low induced attenuation
within the operating temperature range.
íe Fiber geometry are strictly monitored to ensure superior transmission performance.
roll,box,drum
14 Fire Extinguishers Products Suppliers
Short on time? Let Fire Extinguishers Products sellers contact you.
Applications:
Long distance outside telephone, catv, data, communications.
Installations:
Installed in duct, self supporting (figure 8 self supporting or adss all dielectric self supporting) and direct burial
(with armoring).
Construction:
The cable consists of 5 to 36 elements stranded in up to 3 layers around a central strength member and bound in a
Jacket. The elements are usually fiber containing tubes. However, fillers are also used, when needed to preserve cable
Geometry. Two to twelve color coded fibers are loosely laid in each tubes filled with water-blocking gel.
Technical parameters:
Maximum transmission distance: 6km (single mode); 0.3km (multimode)
Maximum pulling load: 1500-2700 n (short term installation); 900-1500n (long term installation)
Minimum bending radius:
Short term installation: 20 x overall diameter
Long term installation: 10 x overall diameter (non armored); 20 x overall diameter (armored)
Twist (torsion length): 125 x overall diameter
Working temperature: -40íµ ~ +70íµ (pe sheath)
Storage temperature: -50íµ ~ +70íµ (pe sheath)
Product highlights:
All the fiber containing tubes are placed in concentric layers around the central member; through the control of
The twist length, the fiber cable can achieve better pulling load and operating temperature.
Tube materials are water resistant and can sustain high tension. Being filled with special water-blocking gel, the
Tube can provide water protection for the fibers inside the tube.
Central member, which is usually either made of dielectric frp, or solid/ stranded steel coated with polyethylene,
Are placed at the centre of the cables.
Applications:
10base-t, 100base-t4, 100base-tx, 100base-vg-anylan, 155mbps atm, 622mbps atm
Working frequency:
1-100mhz
Technical parameters:
Characteristic impedance: 100ía15ª+
Nominal velocity of propagation(nvp): 69%
Maximum dc resistance: 9.38ª+/100m
Maximum mutual capacitance: 5.6 nf/100m
Maximum capacitance unbalance: 330 pf/100m
Maximum resistance unbalance: 5%
Maximum propagation delay skew: 30 ns/100m
Maximum propagation delay: 536 ns/100m 100 mhz
Minimum bending radius: 10 x overall diameter
Voltage rating: 60v rms
Maximum pulling load: 80n
Working temperature: -20 íµ ~ +60íµ
Storage temperature: -5íµ ~ + 50íµ
Flame retardancy: ul 1581 (cm jacket); ul 1666 (cmr jacket); ul 910 (cmp jacket); iec 60332-1 (frpvc
& lszh jacket); iec 60332-1 & iec 60332-3c (lsfroh jacket)
Product highlights:
Provide excellent bandwidth beyond 100 mhz.
Designed for use in data and voice backbone application.
Meet the strict flame retardancy and environmental requirements in europe and us.
Easily identifiable color code for ease of installation.
Transmission properties:
Freq: 100
(mhz)
í= applications:
10base-t, 100base-t4, 100base-tx, 100base-vg-anylan, 155mbps atm, 622mbps atm, 1000base-t
í= working frequency:
1-100mhz
í= technical parameters:
Characteristic impedance: 100ía15ª+
Nominal velocity of propagation(nvp): 69%
Maximum dc resistance: 9.38ª+/100m
Maximum mutual capacitance: 5.6nf/100m
Maximum capacitance unbalance: 330pf/100m
Maximum resistance unbalance: 5%
Maximum propagation delay skew: 30 ns/100m
Maximum propagation delay: 536ns/100m 100mhz
Minimum bending radius: 10 x overall diameter
Voltage rating: 60v rms
Maximum pulling load: 80n
Working temperature: -20íµ ~ +60íµ
Storage temperature: -5íµ ~+50íµ
Flame retardancy: ul 1581 (cm jacket); ul 1666 (cmr jacket); ul 910 (cmpjacket); iec 60332-1 (frpvc
& lszh jacket); iec 60332-1 & iec 60332-3c (lsfroh jacket)
í= product highlights:
Provide excellent bandwidth beyond 200 mhz.
Designed for use in data and voice backbone application.
Meet the strict flame retardancy and environmental
Requirements in europe and us.
Easily identifiable color code for ease of installation.
Different jacket options available for choice.
í= transmission properties:
Freq: 200
(mhz)
Working frequency:
1-100mhz
Technical parameters:
Characteristic impedance: 100ía15ª+ (1-100mhz)
Nominal velocity of propagation(nvp): cmx, cm, cmr,
Lszh 69%; cmp 72%
Maximum mutual capacitance: 5.6nf/100m
Maximum capacitance unbalance: 330pf/100m
Maximum dc resistance: 9.38ª+/100m
Maximum resistance unbalance: 5%
Maximum propagation delay skew: 30ns/100m
Maximum propagation delay: 536ns/100m100mhz
Minimum bending radius: 10 x overall diameter
Voltage rating: 80v rms
Maximum pulling load: 80n
Working temperature: -5íµ ~+50íµ
Storage temperature: -20íµ ~+60íµ
Flame retardancy: ul 1581 (cm jacket); ul 1666 (cmr jacket); ul 910 (cmp jacket); iec 60332-1(frpvc
& lszh jacket); iec 60332-1 and iec 60332-3c (lsfroh jacket)
Product highlights:
Provide excellent bandwidth beyond 100 mhz.
Meet the strict flame retardancy and environmental requirements in europe and us.
Different jacket materials available for choice.
Guaranteed acr value > 0 db 200 mhz.
Special purpose cables can be offered according to customer request.
Different jacket color options available for choice.
í=transmission properties:
Freq: 350;
(mhz)
Application
These cables are designed for transmission of analog and digital signals, and the interconnection of electrical equipment and instruments, particular for the process control industry.
Conductors: Annealed solid copper(Class 1), stranded(Class 2), or flexible(Class 5) to BS 6360.
Insulation: PE/XLPE
Screen:
(Overall Screen)
(Individual Screen + Overall Screen)
(Overall Screen + Steel Wire Armour)
(Individual Screen+ Overall Screen+Steel Wire Armour)
Sheath Version: PVC/LSF/LSOH
Pair Identification:
a) Collectively screened cables: Color coded in accordance with Color Code as per BS5308 standard.
b) Individually screened pairs: One white core and one black core in each pair. Pairs identified by numbered screen isolation tape.
Reference Standard: CW1198
Application: This cable is used for communication and telephone systems, distribution cabling and direct buried.
Conductor Material: Solid plain annealed copper referred to BS6360
Insulation Material: Cellular High Density Polyethylene
Laying-up: Pairs; Units
Wrapping: Polyester Tape
Filler: Petrolatum Jelly filled
Screen: Aluminum foil with overlapping
Bedding: Polyethylene.
Application
6181B is cord for use in machine tools and electrical appliances.
Conductor
Extra flexible copper conductor
Insulation
PE/XLPE insulation
Core
Single core and multi core conductor from 0.5-1000 mmsq
Armouring:
Armoured and unarmoured available
Jacket
PVC/LSOH/LSF.
Application: Power limited circuit, remote control, signaling, security systems, communications, intercom/P.A. systems, sound/audio, and nurse call.
Conductor Material: Bare copper wire strands
Insulation Material: PE/PVC
Laying-up: Units
Drain Wire: Solid bare copper
Shield: Overall Al/Polyester foil shield
Nylon Rip Cord: 150D
Sheath Material: PVC/LSF/PE
Sheath Color: As your request
Shape: Circular in cross-section
Voltage Rating: 300/500 voltage
Temperature Rating: 75íµ
Fire Performance
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperature Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24.
14 Fire Extinguishers Products Suppliers
Short on time? Let Fire Extinguishers Products sellers contact you.