Please click here to check who's online and chat with them.

Find Verified Heating Air Conditioner Ventilation Suppliers, Manufacturers and Wholesalers

Jan-19-17
 
Smoke and smell prevention with the high efficiency (minimum smell loss & efficiency loss)
World-Famous TRION electrostatic filters
Emergency stop button, Control panels which have dirt measurement sensors,
provide speed control
Smell proof high efficient carbon filters with cylindrical cartridges
which can be adjustable due to needed flow rate

-
Jan-19-17
 
Eurovent certified
In the range of 0- 100.000 mâ³/h air flow rate
High energy efficiency and manufacturing quality
Improved air quality
Low noise levels
Customer satisfaction-oriented, well-educated technical support

-
Jan-19-17
 
Ceiling type heat recovery units
8 different models
In the range of 500-5.000 mâ³/h air flow rate
High energy efficiency & air quality
User friendly control panel
Fast service and technical support
Availability of heater with water or electricity
Communication with bms (compatible with the automation)

-
Jan-19-17
 
Our fire damper (bfd-cs) with en 1366-2:1999 eis 120 certification and ce market.
E: integrity
I:insulation
S:smoke leakage
120 â?? value in minutes of eis classification periods (120 minutes resistance). Fä±re damper is a part of fire wall and it must be closed during fire.Fire dampers should have thermal sensors. The damper has special gasket providing tightness between wall and casing, intumescent gasket, 30 mm thick calsium silicate board, high temprature resistant silicone.

-
Jan-19-17
 
70 kg/m3 density, 20 mm thickness fire rated rockwool is used between the blade walls. Fire dampers are used for the purpose of preventing the fire and smoke from diffusing to other places with air ducts in building ventilation systems. The fusible link mechanism that is presented at the damper provides the blade in the damper to close by driving with the return spring when it reaches at 72°C and prevents the fire from diffusing to other places. Also, it can be controlled with servomotor automation system, as well. The fusible link is fixed to the damper on the face where damper handle is presented in such a way that it can be replaced easily.
3413 Heating Air Conditioner Ventilation Suppliers
Short on time? Let Heating Air Conditioner Ventilation sellers contact you.
Jan-19-17
 
Rectangular sound absorbers and Round sound absorbers are used for providing the absorbtion of the sound occuring in air conditioning and ventilation systems, the filling materials inside the splitters are 2 pieces of glasswools that have one surface coated with fiberglass with 50 mm thickness and 70 Class.Rectangular sound absorber whose splitter thickness is 100 mm and 200 mm.Round sound absorber whose splitter thickness is 100 mm and 200 mm.
Jan-19-17
 
Air Handling Units with Direct Expansion Coils
No need of any chiller and/or hot water boiler
Capable of air conditioning with only a VRF outer unit
High COP values, Low initial investment costs
Easy and fast solutions for small and medium sized facilities
Jan-19-17
 
Channel Type Fans
Highly efficient rectangle channel type fan
In the range of 950-9.500 m³/h air flow rate
Metal sheet with the durability of corrosion
Low noise levels
Ease of installation
Speed control

-
Nov-11-16
 
General information

Air to water heat pipe heat exchanger is mainly to heat water using the hot air from heat recovery, it can be used for domestic water, water for boilers or production process. The exchanger is constructed using a partition in the middle to separate the exchanger, both sides are independently sealed. A single heat pipe can be replaced. While working the hot air flows from one side to the other side, the heat pipe absorbs heat. Meanwhile, cold water flows from the reverse side, the heat pipe releases heat, thus heating the cold water from the reverse side. The outlet temperature is not lower than dew temperature.
Field of application

-feed drying
-cereals and oil processing
-chemical industry
Specification

Advantage:
-high heat recovery efficiency
-seldom temperature difference, fast heat starting, good isothermal
-the speciality of the heat pipe results in a high wall temperature, exhaust gas temperature can be reduced without reaching the acid dew point, avoid the corrosion of the equipment.
Oct-13-16
 
In ruiming assembly special aluminum foil phenolic composite duct system, design color embossed double-sided coating of aluminum foil processing by zrop, a clear pattern, the overall appearance, comfortable and high strength core material, embossing processing, fine strong texture, can also spray harmonic color required, full color matching with the occasion. Widely used in supermarkets, hypermarkets and other occasions with the.
Sep-27-16

Cooling

$10.00K
MOQ: Not Specified
 
For Heating and Cooling Contractors the use of special service pages might include Furnaces repaired and Installed, Water Heaters, Chimney Inspection, Air Conditioning Units Repaired Installed and Replaced etc.

This is a lucrative service to offer and if someone is searching, in your area, for a reliable professional Heating and Air Conditioning company you want to be the first option they see.
Aug-11-16

Air-Cooled & Water Cooled

$94.15K
MOQ: Not Specified
Supplier From Bengaluru, Karnataka, India
 
Robust Design.
Designed according to Indian conditions.
Certified components only used.
CNC bended pipes used only, no elbows used.
May-13-16
 
Lsg-3000 moving detector goniophotometer completely meets lm-79 clause 9.3.1 requirement. The lsg-3000 is an automatic light distribution intensity 3d curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, led or hid luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.



Measurement:

Luminous intensity data, luminous intensity distribution, zonal luminous flux, luminaries efficiency, luminance distribution, coefficient of utilization, luminance limitation curves glare, maximum ratio of distance to height, equal illuminance diagrams, curves of luminaires vs lighting area, lsocandela diagrams, efficient luminescence angle etc.



Features:

many national patents pending on hardware and software.
cie class a & constant temperature photo detector (class l detector can be optional).
high degree of intelligent and test function is complete.
the rotation motor is from japan mitsubishi motors and it uses germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop.
the working principles are according to iesna and cie. This instrument is specially recommended by lm-75, lm-79 and cie121-1996.
with some optional instruments, it has good expanding functions
the position and working state remain the same as it is under working.
special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries.





Wooden case
May-13-16
 
Emi-9ka is an automatic emi receiver. It is a main test system for emi (electro magnetic interference) testing. The emi-9ka is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the emi test system, it solved the instrument self-emi problem. The test results are according to the international format test report. The emi test system emi-9ka fully meets cisprl6-1, gb17743, fcc, en55015 and en55022.

Specification:
• detection frequency range: 9khz~30mhz ( emi-9ka) or 9khz~300mhz ( emi-9kb)
• frequency stability: 1x 10-6
• frequency resolution: (9khz~150khz) 30hz; (150khz~30mhz) 1khz
• test tolerance: ±2 db
• measure and detection method: pk, qp and av range from 20dbµv to 140dbµv
• test time: setting by customers
• frequency scanning step length: 20hz~2mhz
• sweep bandwidth: 200hz; 9khz; 120khz
May-13-16
 
Introduction:

Esd simulator (electrostatic discharge generator or electrostatic gun) is in full compliance with iec 61000-4-2, en61000-4-2, iso10605, gb/t17626.2, gb/t17215.301 and gb/t17215.322. The esd generator is designed for the assessment of electrical and electronic equipment to withstand esd performance. Esd61000-2/esd61000-2a has lcd display in both english and chinese, they equipped with an infrared remote control which can allow you do the test in some special place.

Specifications:

Product model
Esd61000-2
Esd61000-2a
Output voltage
0.1~20kv±5%
0.1~30kv±5%
Polarity
Positive/negative
Positive/negative
Energy storage capacitance
150pf±10% (replaceable)
150pf±10% (replaceable)
Discharge resistor
330o±5% (replaceable)
330o±5% (replaceable)
Current rise time
0.6~1ns
0.6~1ns
Testing functions
Single, count, 20pps, air, contact, iec level
Single, count, 20pps, air, contact, iec level
Trigger mode
Manual/auto
Manual/auto
Numbers of discharge
1~9999
1~9999
Repetition
0.05s~99.99s
0.05s~99.99s
Working power
Ac220v(option 110v)±10%, 50/60hz
Ac220v(option 110v)±10%, 50/60hz

Touch screen with super big lcd and built-in windows ce



Calibrate report:
Output voltage (kv)
First peak current (a)
Current at 30ns (a)
Current at 60ns (a)
Rise time (ns)
2
7.29
4.10
2.20
0.93
4
15.40
7.90
4.30
0.97
6
23.20
12.10
6.50
0.97
8
29.40
16.20
9.30
0.89
-2
7.39
3.50
2.30
0.92
-4
15.50
7.70
4.30
0.89
-6
23.40
11.90
6.30
0.90
-8
31.80
16.10
8.20
0.90

Note: metal holder needs extra cost.
Jun-05-24
 
The cooling tower fan is located at the top of the cooling tower, which is directly connected with the motor or indirectly connected with the gearbox and pulley. The fan draws the hot air in the cooling tower after heat exchange from the top and guides the low-temperature air to enter from the air inlet of the bottom cooling tower.


As a professional cooling tower manufacturer, we also provide plastic or FRP (fiberglass) cooling tower fans or fan blades at good prices. You can surely pick out what you need from the different types of industrial cooling tower fans below.
Jun-05-24
 
Closed Circuit Cooling Tower
Closed circuit cooling tower (also known as an evaporative air cooler or closed cooling tower) is the tubular heat exchanger placed in the tower, through the circulation of air, spray water and circulating water heat exchange to ensure the cooling effect.

AUVC not only provides different shapes of cooling towers used in industries, such as round shape cooling towers and square cooling towers, but also offers closed cooling towers and open circuit cooling towers as well. The type of closed circuit cooling tower is widely used in iron and steel metallurgy, power electronics, machining, air conditioning system and other industries.

How do closed circuit cooling towers work?
Closed-circuit cooling towers make it possible to separate the evaporative circuit from the process circuit (customer circuit). A stainless-steel plate heat exchanger attached to the cooling tower, in its dedicated room, allows a glycol-free operation, and a simplified and unequalled ease of maintenance.

The closed circuit cooling tower works as follows
On the process side to be cooled (customer loop), the water to be cooled enters a plate heat exchanger connected to the tower and is cooled and discharged. The primary loop is closed and never comes into contact with air.

On the secondary side of the cooling tower, the water is sucked out of the pool by a pump and circulated through a stainless steel plate heat exchanger. The water leaving the exchanger is piped to the top of the unit. This water is graded and evenly dispersed over the exchange surfaces by dispersers (also known as water distribution nozzles). Air driven by fans (axial or centrifugal) enters from the lower part of the cooling tower, is heated and saturated with water and exits from the upper part, passing between the exchange surfaces.

Under the effect of the surface tension of the filler ladder, the water spreads uniformly and flows away over the entire height of the tower. The exchange surface is thus increased.

The water cooled by forced ventilation falls freely into an inclined pool located at the bottom of the unit.

Types of Closed Type Cooling Tower
Jun-05-24
 
Cooling Tower Motors
Cooling tower motor is a new type of energy-saving and environmental protection improved motor, with protection grade of IP55, insulation grade of B, and power supply voltage of 380V and 50Hz. Generally, a closed waterproof motor is used in the cooling tower, which can operate for a long time in outdoor humid and high temperature environments. The cooling tower motor material is cast iron and aluminum shell.

Derived from one of the most rugged motor platforms used in the most demanding industrial applications, direct drive motors are the right solution for operation in hot and humid environments in towers. Direct drives are ideally suited for cooling towers, air-cooled condensers and air-cooled heat exchangers.
May-04-24
 
Melco 4015 4CM CA1382-H01
MMF-04C24DS RC4 24V 0.09A Cooler Fan
For Inverter / Server / ABB product
Supply: Competitive products & Competitive price
May-04-24
 
109R0612G402 12V 0.24A 2 Wires 2 Pins Case Fan
6CM DC Square Func Fan / Cooling Fan
For Case / notebook / CPU / Switch / Inverter / DIY
Supply: Competitive products & Competitive price
3413 Heating Air Conditioner Ventilation Suppliers
Short on time? Let Heating Air Conditioner Ventilation sellers contact you.