1.Gear ratio: motors are available with any one of the following standard gear reduction ratios of 10, 30, 100, 300, 1000, 3000. (basic rotor speed is 2500 rpm). 2. Windings: motor windings are designated by means of two letters. First letter refers to the voltage to the reference phase and the second letter to the voltage on the control phase. The letter code for voltages is as follows: a = 230v, b = 115v, c = 115-0-115v, d = 23v, e = 11.5, f = 11.5-0-11.5. Standard cotton box or as per customer requirement.
Smart combination of *Air conditioning heating *Air conditioning cooling *And clean sanitary water heat pump heater. Two water tanks built inside. Seperate water cycle for air conditioning and domestic water. 4 times energy saving as normal gas or petrol heater. 1/4 of normal bill help you to win the whole unit free in one year. Main characters: 1. Challenge daikin similar "altherma" unit with improved function and daikin compressor. 2. Air conditioning cooling, heating and sanitary hot water function in one unit. 3. Multiple indoor units with one outdoor unit. 4. Perfectly suitable for floor radiation heating system. 5. Extrimly energy saving, super cost saving. 6. Installation is easy and flexible, super compact size. 7. Super low temperature heating start. 8. Can be connected with solar water heater system. 9. All water access parts are stainless steel to keep safe, healthy and non-pollution 10. Fault self diagnosis and warning function. 3aqua-11 3aqua-14 3aqua-19 Air heating capacity km 10 14 19.3 Input power km 2.74 3.8 5.15 Cop 3.65 3.68 3.75 Air cooling capacity km 8.3 12.3 15.9 Input power km 2.85 4.15 5 Eer 2.91 2.96 3.18 Acs(sanitary hot water) capacity km 10.4 14.2 19.4 Input power km 2.85 3.85 5.15 Cop 3.65 3.69 3.77 Power supply v/ph/hz 230/1/50 380/3/50 Refrigerant r-410a Acs water tank volume l 90 Air conditioning tank volume l 50 Dimensiones indoor mm 1360*590*590 Outdoor mm 860*870*325 960*970*345 1460*970*345 Weight indoor kg 128 132 Outdoor kg 70 98 130 Noise indoor db(a) 28 Outdoor db(a) 47 48 50.
MODEL CFM FAN MODEL (MM) COIL AREA (SQFT) HEIGHT (MM) WIDTH (MM) DEPTH (MM) RADSFM-12 1200 180 2.4 770 774 1200 RADSFM -15 1500 200 3.0 810 811 1250 RADSFM-20 2000 250 4.0 850 927 1320 RADSFM-25 2500 280 5.0 855 1005 1400 RADSFM-30 3000 315 6.0 855 1170 1300 RADSFM-35 3500 355 7.0 918 1284 1550 RADSFM-40 4000 35S 8.0 982 1284 1570 RADSFM-45 4500 400 9.0 1100 1284 1650 RADSFM-50 5000 400 10.0 1100 1326 1650 RADSFM-55 5500 450 11.0 1172 1350 1750 RADSFM-60 6000 450 12.0 1236 1372 1750 RADSFM-70 7000 500 14.0 1400 1560 1900 RADSFM-80 8000 500 16.0 1400 1660 1900 RADSFM-90 9000 560 18.0 1400 1740 2050 RADSFM-100 10000 560 20.0 1490 1744 2050 RADSFM-110 11000 630 22.0 1490 1890 2200 RADSFM-120 12000 630 24.0 1553 1956 2200 RADSFM-150 15000 710 30.0 1680 2190 2350 RADSFM-160 16000 710 32.0 1680 2334 2350 RADSFM-180 18000 800 36.0 1744 2550 2550 RADSFM-200 20000 800 40.0 1807 2624 2550 RADSFM-220 22000 900 44.0 2022 2742 2700 RADSFM-250 25000 900 50.0 2100 2845 2700 RADSFM-280 28000 1000 56.0 2650 2961 2900 RADSFM-300 30000 1000 60.0 2650 3150 2900.
Pre painted steel for air conditioner.
Suitable for low/medium/high pressure air ventilation and air condition systems. Easy to install oval or round connection. At high temperatures or in case of fire, no toxic gas emission. Diameter range: 50mm to 508mm Max. Air velocity: 30m/s Temperature range: -30 ~ +150 Standard length: 10 m Working pressure: max. 2500pa
Standard construction : Frame: 8"x11/4"x16ga. galvanized steel channel with comer braces. Flange: Corner 0.4" dia. x 8 EA for installation bolt holes. Blades: 6" width 16ga. galvanized steel. Approx 6" on center. Linkage: Concealed in frame or face linkage inside of air stream. Bearings: sleeve bearing Axles: 1/2" dia. galvanized steel. MIN. Damper size: PB single blade-5" W x 4" H, OB-8" W x 14" H MAX. Section size: 48" x 72" MAX. damper size: unlimited. Hand quadrant: for manual operation Steel construction: welded constructions Axles: bolted to blade and tag welded. Finish: Galvanized steel zinc plated hardware. Installation instruction Air flow rate control between Duct and Duct bolt conection Variations(at extra charge) 1. Special finish 2. Special material: alum., stainless steel, etc. 3. Special blade seals and axle shaft seals 4. Special thickness of blade or frame.
Standard construction Frame: 20ga. galvanized steel. Blade: Single blade 20ga. galvanized steel Axle: 3/8" dia. galvanized steel bolted to blade Max. section size: 18" dia. Min. section size: 4" dia. Hand Quadrant: for manual operation Installation instruction Air flow rate control Between Duct and Duct bolt connection Variations 1. Special finishes 2. special materials 3. Special thickness of blade or frame Note 1/8" deducted "D" unless otherwise specified.
Standard construction Frame: 8"x11/4"x16ga. galvanized steel channel Flange: Corner 0.4" dia. x 8 EA for installation bolt holes. Blades: 22"Ga. galvanized steel upto 36" length. 22"Ga. galvanized steel upto 48" length Min blade dimension: 6" Linkage: Concealed in frame or face linkage inside of air stream. Bearings: sleeve bearing Axles: 1/2" dia. galvanized steel. MIN. Damper size: PB single blade-5" W x 4" H MAX. Section size: 48" x 72" MAX. damper size: 72" x 72" Steel construction: welded constructions Axles: bolted to blade and tag welded. Finish: Galvanized steel zinc plated hardware. Installation instruction Air flow rate control between duct and duct bolt conection Variations(at extra charge) 1. Special finish 2. Special material: alum., stainless steel, etc. 3. Special blade seals and axle shaft seals 4. Special thickness of blade or frame.
Chillers from 5 to 400 tons for large yachts and boats.
The H-type thermal expansion valves for auto air-conditioners are such valves which expand on heat by interiorly temperature sensing and exteriorly balancing. They feature a sensitivity and reliability in temperature sensing, firmness against the pressure dropping-down with the evaporator, vibration resistance, easiness of regulating etc.. Apart from reference to American, Japanese and other international auto standards, our QRFWH serial expansion valves also represent advanced technologies and special characteristics.
The h-type thermal expansion valves for auto air-conditioners are such valves which expand on heat by interiorly temperature sensing and exteriorly balancing. The feature a sensitivity and reliability in temperature sensing, firmness against the pressure dropping-down with the evaporator, vibration resistance, easiness of regulating, etc. Apart from reference to American, Japanese and other international auto standards, our qrfwh serial expansion valves also represent advanced technologies and special characteristics. Key specifications/special features: * international and domestic advanced sealing structure in the balancing part (patent number: zl96120084.7) * advanced technology for the steel ball sealing of the bellos (patent number: 02137156.3) * advanced negative static overheat technology (patent number: zl02257444.1) * top sensitive of regulating * steady regulation with small fluctuation * little leak in the balancing part * the bellows works reliably with no leak * no whistle noise * long service life.
DHF 4-way reversing valve, the key part of the heat pump air conditioner, diverts the direction of the refrigerant flow under the electromagnetism of the pilot valve to supply either heating in winter or cooling in summer to the conditioned place. The character of the design of the DHF series is twice-opening, the diversion is controlled by the pilot valve, ensuring the high reliability of operation. Key specifications/special features: It diverts the direction of the refrigerant flow under the electromagnetism of the pilot valve to supply either heating in winter or cooling in summer to the conditioned place Capacity: 4kw Power: 3/4 to 1.5hp Internal leakage:
1.Material: Aluminum. Frame thick:1.0mm, blade thick: 1.0mm,weight:1.7KG 2.Powder coated white or anodized 3.Used for the supply and exhaust of cooled and heated air. 4.The centre core is removable for easy maintenance. 5.Be together with VCD-A,VCD-B,VCD-C
1 flange aluminum 6063-t5 length:4m/pc 2 u-flange aluminum 6063-t5 length:4m/pc 3 chair flange aluminum 6063-t5 length:4m/pc 4 invisible flangea luminum 6063-t5 length:4m 5 invisible flange&h flange pvc length:4m/pc Pvc flange use with aluminum flange together 6 aluminum foil tape specifications:/5cm*3000cm d=30m w=3cm b/7.2cm*3000cm d=30m w=7.2cm
1 flange aluminum 6063-T5 length:4m/pc 2 U-flange aluminum 6063-T5 length:4m/pc 3 chair flange aluminum 6063-T5 length:4m/pc 4 invisible flangea luminum 6063-T5 length:4m 5 invisible flange&H flange PVC length:4m/pc PVC flange use with aluminum flange together 6 aluminum foil tape specifications:/5cm*3000cm d=30m w=3cm B/7.2cm*3000cm d=30m w=7.2cm
Cooling capacity : 18400-27900
Type of generator:TFW-20 Rated output:20KW Rated voltage:380V Rated frequency:50Hz Rated Current:36.1(A) IP:21 Insulation:F Power factor:0.8 Excitation:three phase, brushless Dimension:1780í-750í-1000 (mm) Weight:750kg Package:Wooden Case
Air conditioner parts
CAC(copper-aluminum-copper) tube is used to connect the air conditioner's indoor and outdoor unit. Both end of the CAC tube is copper tube, in the middle is Aluminum tube, copper tube and aluminum tube are welded together by a special welding technic. So the cost of CAC tube is much less than the copper tube. Aluminum tube wall thickness is 1.5 times of copper tube, combine our outstanding welding technic, the service life of CAC tube is more than 20 years, it totally reach our standard requirement.
Ih single stage single suction centrifugal pump Detailed product description Is ih single stage single suction centrifugal pump Ih single stage end suction centrifugal pump Air conditioning pump This pmp is a centrifugal end suction pump, it is now wildly used in industries like cooling, air conditioning, and aslo in resident, water supply. Is pump is especially for normal water. Ih pump is especially for chemicals. It has the function of pumping corrosive liquids. Is pump can pump water bellow 80 dgree centigree, if you want to pump water with high tempreature, we recommend you choose ir, which is same to is in structure and outlook, but is has good function of pumping water with temperater reaching 150degree centigree. For ih pump, it can pump liquids with temperature reaching 120 degree centigree. Also, if you want to pump oil in this size, please choose iry type which can reach 350 degree centigree. Capacity: 6 - 200m3/h, head: 5 to 150 meters. (special demand can be negotiated) Standard export wood case packing