Theodoor heat pump (unit) is the world's most energy-efficient water heating equipment, through the national association of energy recognized the "green energy-saving products, " theodoor heat pump is the use of the lessons of the heat in the air, making 55-60 centigrade ( up to 65 centigrade) water quality of life. Schools, hospitals, hotels, factories, villas, family and so on need to use all the hot places can be used to install. Theodoor heat pump user can set the temperature of hot water to run automatically in a row, for water heating, highly intelligent, flexible and easy to use, energy saving and environmental protection, safe, reliable, convenient maintenance features, is a unit of family life and ideals of hot water supply products
Theodoor air source heat pump (unit) is the world's most energy-efficient water heating equipment, through the National Association of Energy recognized the "green energy-saving products," Theodoor air source heat pump is the use of the lessons of the heat in the air, making 55-60 centigrade ( Up to 65 centigrade) water quality of life. Schools, hospitals, hotels, factories, villas, family and so on need to use all the hot places can be used to install. Theodoor air source heat pump user can set the temperature of hot water to run automatically in a row, for water heating, highly intelligent, flexible and easy to use, energy saving and environmental protection, safe, reliable, convenient maintenance features, is a unit of family life and ideals of hot water supply products.
Remote control No fixed installation Quiet and efficient cooling to any room Adopt automatic water pump Automatic protected function Indpendent dehumidification Programmable 24-hour timer or continuous operation Extendable exhaust duct Micro-processor control Voltage:110v/60hz 220v/50hz 220v/60hz R407c and r410a environment-protecting refrigerant or r22 refigerant Automatic water pump drairage and automatic water evaporation Function:wind/cooling/dehumidity/heating Rated voltage:220v Rated frequency:50hz Rated cooling capacity:3.5kw/12000btu Cooling input power:1.33kw Cooling start-up current:6a Heating capacity:1.8kw Heating input power:1.73kw Heating start-up current:9a Relycling wind speed:380m2/h Refrigerant:r22 r407c r410a Cooling area:15m2 Noise:¿q50dbú¿aú Operating ambient:-5ú¡45íµ Overall size/package size:485íß430íß860mm Weight:33kg
We can produce ac assembly line which is suitable for window ac, split-ac, and floor-type ac, etc. And if you want to know more details about our products, please feel free to contact us.
Safety pe material. 65qt/ 80qt.
Water fog system for cooling the outdoors and for creating mind-boggling visual effects.
FOG system is used for cooling the outdoors by upto 17¦C. And FOG can bring the hill station climate in your backyard 24X7, 365 days a year.
Fog system generates very fine droplets in the range of 20 microns and less which attack the floating dusts particles and making them heavier settle them on the ground thus rendering the atmosphere clean.
Wall split, and all other types. Excellent quality! americanpro brand visit us on the web! Americanpro.
1.Classic appearance Classic design of water cassette can make itself better compatible with your indoor decoration style. Also, based on different requirments, 2 or 4 way pipe can be chosen for carrying different volumn of wind.
1.Classic appearance Classic design of water cassette can make itself better compatible with your indoor decoration style. Also, based on different requirments, 2 or 4 way pipe can be chosen for carrying different volumn of wind.
Comes in many sizes, used fo exhausting hot air, fumes, bad smel 30" x 30" x 22"
The air ventilator is a revolutionary conceptual product which exhausts the hot gases from an enclosed area without using any electric power. Yes absolute zero power consumption. It has no operating cost and gives excellent ventilation performance making the work areas like boiler / furnace / oven sheds, curing and drying areas, casting and molding sheds, workshops, process area utility sheds, dg sheds, compressor houses, power house and packing area, go-downs, etc more cooler and comfortable to work in. The air ventilators are most cost effective substitute to the exhaust fans which continuously gulp the electric power and also have maintenance problems.
The air ventilator is a revolutionary conceptual product which exhausts the hot gases from an enclosed area without using any electric power. Yes absolute zero power consumption. It has no operating cost and gives excellent ventilation performance making the work areas like boiler / furnace / oven sheds, curing and drying areas, casting and molding sheds, workshops, process area utility sheds, dg sheds, compressor houses, power house and packing area, go-downs, etc more cooler and comfortable to work in. The air ventilators are most cost effective substitute to the exhaust fans which continuously gulp the electric power and also have maintenance problems
Air conditioner
Cooling capacity: 15.0kw (13000kcal/h, 51000btu) Compressor: tm31 (dks32) Compressor weight: 14.5kg Compressor discharge volume: 313cc/r Refrigerant: r134a Evaporator air flow: 3200 m3/h Condenser air flow: 4500 m3/h Total current: 50a24v Drawing dimension: l: 2676mm w: 1483mm h: 190mm Bus model: 6.5m-7.8m Drawing dimension: l:2676mm w:1483mm h:190mm
Cooling capacity: 5.25kw (4500kcal/h, 18000btu) Compressor: 5h14 compressor weight: 7.9kg Compressor discharge Volume: 138cc Refrigerant: r134a Evaporator air flow: 650 m3/h Condenser air flow: 1800 m3/h Total current: 20a24v Drawing dimension: l: 760mm w: 754mm h: 162mm Vehicles model: minibus, truck cab, construction machinery cab etc Drawing dimension: l:760mm w:754mm h:162mm
Cooling capacity: 9kw (8000kcal/h, 31000btu) Compressor: 7h15/tm16 Compressor weight: 7.9kg Compressor discharge volume: 167cc Refrigerant: r134a Evaporator air flow: 1000 m3/h Condenser air flow: 2600 m3/h Total current: 22a+24v Drawing dimension: l: 1010mm w: 970m h: 180mm Vehicles model: minibus, special vehicles etc +11-17seats Drawing dimension: l:1020mm, w:980mm h:189mm
Application area; especially operating theatres, pharmaceutical industry, chemical industry, food production, electronic industry and research laboratories. Sensitive applications in aforementioned application areas require a ventilation system suitable for conditions specified in standards.Gonka laminar flow extract systems reduce microorganism contaminants and particulate concentrations in air to the minimum level in accordance with the standards. Hepa filters which clean filtrated air before going into operating room. Mounting situated in ceiling of the operating theatre in such a way that it should locate over operating table. Stainless steel air distribution box, hepa filters, transparent air distributor (laminarizator) and pendant operating table lighting connection. Easy maintenance and disinfection because of transparent air distributor's being pulled down. Operating theatre lighting system made up of airproof construction. A laminar, vertical air flow from transparent air distributor through operating table prevents turbulent air flow in conventional air systems and offers a high level cleanliness class around the operating table during the operati The system which remove particulates and microbes from operation part due to laminar flow. Special design for operation theatres which require especially high level sterilization in accordance with din 1946. Differential pressure sensors. Easy connection differential pressure sensors and leakage testing. Easy installation to all kinds of ceilings. Depends model
Air handling unit (ahu) 8 different models which provide required humidity and temperature by conditioning air volume in wide ranges. Standard series Application area: business centers, schools, hospitals, factories, hotels and restaurants. 8 different models which provide required humidity and temperature by conditioning air volume in the range of 3000m¦/h and 100.000 m¦/h. The framework which is formed by combination of aluminum frames, which are connected specially, with plastic and aluminum comers. Boards which are made up of double skilled galvanized iron in a standard way. Polyurethane insulated panels, which are 30 mm in thickness, for thermal and acoustic insulation in a standard way. Standard accessories; Filter chambers; chamber design which provides easy mounting and de-mounting in filters and filters with different productivity levels on demand. Heating and cooling coils; seamless cooper tubes. In heating coils, 4 options: warm water, vapor, hot water, electrically heated; in cooling coils, 2 options: chilled water and dx (direct expansion). Dampers; rigid aluminum frame in multi airfoil structure which is the least resistant against airflow. Rubber gaskets which reduce air leakage through blades to the minimum level. Fans; statically and dynamically balanced aspirators and ventilators in double inlet belt driven centrifugal type. Forward curved fans in systems with low, medium and high duct pressures, . Optional accessories; Gonka vapor humidifier, standard vapor cylinder, immersion electrodes, stainless vapor distributor and microprocessor control unit. Mufflers which are made up of coulisses to provide required sound holding capacity. Plate heat exchanger or heat recovery wheel for recovery of the heat emitted with exhaust air. Electrical board. Frequency converter Depends on the size, model and chambers