Hot air oven dryer works with hot air circulation method, adopts electric heating or steam heating. The heating system provides hot air, and the ventilation and dehumidification system circulates the hot air to discharge the moisture in the room according to the process requirements, while supplementing with fresh air. â?? The automatic control system can control the heating, cooling, and dehumidification operations of the drying process according to the set drying process. The hot air dryer is equipped with one and more mobile trolleys and baking trays inside. Heating type:Electric,steam.â?? Classified with trays: 24,48,96,144,192trays. Hot Air Oven Dryer Model:VG-HG24 Size:1600*1200*2350mm Heating type:Electricity Main material:Stainless steel Power:13kw Trays:24pcs Tray size:640*460*45mm Temperature:Adjustable Voltage:380V/50HZ or others Warranty:One year After sales service:Video and online meeting
Flameless Quench Device, or Flameless Venting Device. Product execution standards GB/T15605 Dust explosion pressure venting guide. EN16009 Flameless explosion venting devices. Parameters of Flameless Venting Function Parameter Model FEVDS135 Flameless Quench Device Static activation pressure Relevant to the selection of the venting element. Default valve is 0.01MPa�±25%. Maximum reduced explosion overpressure Pred,max 0.0451MPa Venting efficiency 66% Flameless performance No sparks or flame Reusable No reusable Optional accessories Back pressure support, explosion venting detector. Consumables Explosion venting membrane (venting or rapture panel). Applications of Flameless Venting Oxygen content is not higher than that in air (21%); Working pressure is not higher than one atmospheric pressure (0.1 MPa). It is usually used together with explosion venting device. The flameless vent device is used to compose the anti-explosive system. Now the price of dust collector vacuum cleaner is reasonable, if you want to buy dust cleaner machine, please contact us.
If you're searching for a reliable dehumidifier dealer in Kolkata, look no further than Kridovia. As a leading provider of top-quality dehumidifiers, Kridovia is dedicated to improving indoor air quality for homes and businesses throughout Kolkata. With a wide range of models to choose from, Kridovia ensures you find the perfect dehumidifier to suit your specific needs. Whether you're battling humidity in the monsoon season or looking to maintain a comfortable environment year-round, Kridovia offers the best solutions. Discover the benefits of a dehumidifier and enhance your living spaces with Kridovia's expert service and products.
Melco 4015 4CM CA1382-H01 MMF-04C24DS RC4 24V 0.09A Cooler Fan For Inverter / Server / ABB product Supply: Competitive products & Competitive price
109R0612G402 12V 0.24A 2 Wires 2 Pins Case Fan 6CM DC Square Func Fan / Cooling Fan For Case / notebook / CPU / Switch / Inverter / DIY Supply: Competitive products & Competitive price
9025 9CM AD0912HB-A7BGL 12V 0.3A 4 Wires Cooler Fan 9CM Square Cooler Fan For Case Fan/CPU Fan/Power Supply
9CM AD0912UX-A7BGL 372651-001 12V 0.5A 4 Wires Cooler Fan 9CM Square Cooler Fan For Case Fan/ CPU Fan/ Power Supply
7025 7CM AD07012DX257600 12V 0.32A 3 Wires Cooler Fan 7CM Sqaure Cooler Fan For Case Fan/ CPU Fan/ Projector
ARX 7.5CM DC Centrifugal Cooling Fan 12V 0.55A 3Wire For TV transmitters / Inverter / DIY
KDE1204PKV1 MS.A.GN 12V 0.8W 2 Wires Cooling Fan Micro mini Fan Use for Mini Case/Router/switch/Diy devices.
Apex Industries is the prominent leading Manufacturer & Exporter of finest quality Air Handling Units (Pure Air Purifier / Treated Air Ventilation System) for Pharmaceutical, Hospital, Modular Operation Theater and other all Air-conditioning applications, Our products construction heaving rigid framework for the unit comprises an assembly of externally chamfered extruded anodized aluminum profiles and nylon glass fiber corner joints, and incorporated with polyurethane foam, 25 mm / 43 mm / 50mm thick pressure injected sandwiched panels, also we makes the entire unit anti-corrosive and sweat free (thermal break). and imported self-drilling and self-tapping galvanized sheet metal screws adds to the aesthetic & more times stronger of the framework.
Smacna, DW 142-143, DIN 24-194 and TSE standards, production in all sizes and thicknesses from 0.50 mm to 1.20 mm, Internal and external Rubber-Acoustic insulation construction, Galvanized and Manufactured from stainless steel, manufactured in harmony with each other, minimum sealing in flanges and corners, full sealing with mastic after production is provided.
ZL-3 model steam air heater with upper outlet and lower inlet is consists of 9 parts: steel-aluminum radiator fin tube + electric steam valve + drain valve + insulation box + fan + Fresh air damper + waste heat recovery device + dehumidification fan + electric control system. It is specially designed for supporting downflow drying room/heating rooms. After convert the outside steam heat to heat inside the insulation box through by the fin tube, it�´s mixing with recycle or fresh air, under the action of the fan, it is discharged from the upper outlet into the drying room or heating space. Then cooled air pass through the lower air outlet for secondary heating and continuous circulation. And when the humidity of circulating air reaches the emission standard, the dehumidification fan and fresh air damper will start simultaneously. The exhausted moisture and fresh air implement sufficient heat exchange in the waste heat recovery device, so the moisture is discharged and the fresh air with recovered heat enter the circulation system. Advantages/features 1. Simple structure and easy installation 2. Large air volume and small wind temperature fluctuation 3. Stainless steel electric heating finned tube, durable 4. Steel-aluminum finned tubes, high heat exchange efficiency. The base tube is made of 8163 seamless tube which is pressure-resistant and durable; 5. Electric steam valve controls the amount of inlet, automatically cuts off or opens according to the set temperature, so that can accurately controls the temperature. 6ï¼?High temperature and high humidity resistant fan with IP54 protection rating and H-class insulation rating. 7. Integrating the dehumidification and fresh air system, heat loss is extremely small through by the waste heat recovery device. 8. Automatically replenish fresh air
ZL-2 model steam air heater with Left-Right Circulation is consists of 7 parts: steel-aluminum radiator fin tube + electric steam valve + drain valve + insulation box + fan+ Fresh air damper + electric control system. It is specially designed to support the left and right circulation drying room. For example, the 100,000 kcal model drying room, it is equipped with 6 fans, three on the left and three on the right. When the three fans on the left rotate clockwise, the three fans on the right rotate counterclockwise in a cyclic alternating manner, forming a relay, The left and right sides serve as air inlets and outlets alternately, taking out all the heat generated by steam heater. It is equipped with an electric fresh air damper to supplement fresh air in coordination with the dehumidification system in the drying room/drying place. 1.Simple structure and easy installation 2. Large air volume and small wind temperature fluctuation 3ï¼?Steel-aluminum finned tubes, high heat exchange efficiency. The base tube is made of 8163 seamless tube which is pressure-resistant and durable; 4. Electric steam valve controls the amount of inlet, automatically cuts off or opens according to the set temperature, so that can accurately controls the temperature. 5. High-density fire-resistant rock wool insulation box to avoiding heat loss 6. High temperature and high humidity resistant fan with IP54 protection rating and H-class insulation rating. 7. left and right fans run alternately in cycles to ensure even heating 8. Automatically replenish fresh air
ZL-1 model Steam air heater with upper inlet and lower outlet is consists of 6 parts: steel-aluminum radiator fin tube + electric steam valve + drain valve + insulation box + fan + electric control system. Steam passes the though the fin tube, dissipating heat to the insulation box, mixing and heating the fresh or recycle air to setting temperature, fans bring this hot air into drying room or heating room to be used for dehydration, dehumidification or heating. 4. Advantages/features 1. Simple structure, beautiful appearance, low cost 2. Steel-aluminum finned tubes, high heat exchange efficiency. The base tube is made of 8163 seamless tube which is pressure-resistant and durable; 3. Electric steam valve controls the amount of inlet, automatically cuts off or opens according to the set temperature, so that can accurately controls the temperature. 4. Large air volume and small wind temperature fluctuation 5. High-density fire-resistant rock wool insulation box to avoiding heat loss 6. High temperature and high humidity resistant fan with IP54 protection rating and H-class insulation rating.
1. The surface layer adopts super soft and porous design to enhance penetration and absorption 2. The cool chip design prevents genital itching caused by sweltering heat and humidity 3. Super absorbent, the surface will not rewet wet.
Underfloor electric heating.
Belt driven screw air compressor, piston air compressor, air compressor parts, air tank, air dryer, air compressor system.
Indoor heating products, mainly including electric heaters and water heaters.
HVAC equipments.Manufacturing & installation