Main Features: 1.Combinations of cooling,ventilation,air-exchange,anti-dust,and savor-removal. 2.Environment: CFC Free, Nonpollution. 3.Automatic performance with LCD:Electronic control ,cleaning and water supplying antomaticly. 4.Energy-saving:lower daily cost Cabout one kilowatt per hour.Uses 80% less energr-much more economical than comparable traditional air conditioner C giving you tremendous savings. 5.Effectively and efficiently for cooling:5-12oC can be dropped in damp areas while 8-15 oC reduced in hot and dry conditions. 6.Great capacity of ventilation: Produces over 18000m3 of cooling power hour.Can cool areas up to 150m2 and can blow airflow as far as 30 merters away. 7.Option: Single phase various speed or three phase fixed and various speed. 8.Small investment but big effects:One workshop owning 100 sewing machines only needs about 6 units which costs 60% of the investment for traditional compressor air conditioners.All the investmens will be regained within 12 months. Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc.
Principle The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc. Parameter Specifications: Airflow(m3/h): 18000 Power(Kw) : 1.1 Voltage/Frequency(V/Hz) : 220/50 Rated Electric Current(A) 2.8/4.8 Fan Type: Axle Discharge Type : Down discharge Controller Type : Intelligent LCD Motor Type: Single-phase Various Frequency Speed Capability Characteristic Injection shell is using modified PP composite materials and aluminum alloy column precision tectonic process; with the easy pull-out filters, wet screens paper of the frame protection and shockproof design, frame bearing capacity of 100 kg and above,with anti-corrosion, anti - ultraviolet, anti-aging15 years, high and low temperature resistance (subzero 20 C - 50 C) without distortion, and fuselage life for more than 10 years. LCD panel control system, using single-phase various frequency speed, three-phase various speed, three-phase fixed speed intelligent electronic control systems and closed all high-quality match for the electrical, intelligent sewage cleaned regularly, wrong phase, short phase, overload current, water shortages protection and fault alarm function. Adopt Sweden 5090-patented technology evaporative wet paper filter net , and the evaporative area in more than 85%; Using 3 leaves impeller, using silencers acoustic and noise reduction technology, the noise can be controlled lower than 56 dB
Airflow(m3/h): 18000 Power(Kw) : 1.1 Voltage/Frequency(V/Hz) : 220/50 Rated Electric Current(A) 2.8/4.8 Fan Type: Axle Principle·ª The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc.
Principle The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Parameter Specifications: Airflow(m3/h):18000 Power(Kw) :1.1 Fan Type:Axle Discharge Type :up Controller Type :Intelligent LCD Motor Type:Three-phase Fixed Speed Voltage/Frequency(V/Hz) :380/50 Unit Size(mm):1080?1080?980 Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc.
Basic principle: The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Parameter specification: Airflow(m3/h):18000 Power(Kw) :1.1 Fan Type:Axle Unit Size(mm):1080?1080?980 Discharge Type :up Controller Type :Intelligent LCD Voltage/Frequency(V/Hz):220/50 Motor Type:Single-phase Various FrequencySpeed Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc.
1.Automatic performance with LCD:Electronic control ,cleaning and water supplying antomaticly. 2.Energy-saving:lower daily cost ¿Cabout one kilowatt per hour.Uses 80% less energr-much more economical than comparable traditional air conditioner ¿C giving you tremendous savings. 3.Effectively and efficiently for cooling:5-12oC can be dropped in damp areas while 8-15 oC reduced in hot and dry conditions. 4.Great capacity of ventilation: Produces over 18000m3 of cooling power hour.Can cool areas up to 150m2 and can blow airflow as far as 30 merters away. 5.Environment: CFC Free, Nonpollution. 6.Option: Single phase various speed or three phase fixed and various speed. 7.Combinations of cooling,ventilation,air-exchange,anti-dust,and savor-removal. 8.Small investment but big effects:One workshop owning 100 sewing machines only needs about 6 units which costs 60% of the investment for traditional compressor air conditioners.All the investmens will be regained within 12 months.
Principleú¦ The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Parameter Specifications: Airflow(m3/h): 18000 Power(Kw) : 1.1 Voltage/Frequency(V/Hz) : 380/50 Rated Electric Current(A)ú¦2.8/4.5 Fan Type: Axle Discharge Type : Down discharge Controller Type : Intelligent LCD
Parameter Specifications: Airflow(m3/h): 18000 Power(Kw) : 1.1 Voltage/Frequency(V/Hz) : 380/50 Rated Electric Current(A) 2.8/4.5 Fan Type: Axle Discharge Type : Down discharge Controller Type : Intelligent LCD Motor Type: Three-phase Fixed Speed
Parameter Specifications: Airflow(m3/h):18000 Power(Kw) :1.1 Fan Type:Axle Discharge Type :up Controller Type :Intelligent LCD Motor Type:Single-phase Various Frequency Speed Voltage/Frequency(V/Hz) :380/50 Unit Size(mm):1080?1080?980 capability characteristic: Injection shell is using modified PP composite materials and aluminum alloy column precision tectonic process; with the easy pull-out filters, wet screens paper of the frame protection and shockproof design, frame bearing capacity of 100 kg and above,with anti-corrosion, anti - ultraviolet, anti-aging15 years, high and low temperature resistance (subzero 20 fp C - 50 fp C) without distortion, and fuselage life for more than 10 years. LCD panel control system, using single-phase various frequency speed, three-phase various speed, three-phase fixed speed intelligent electronic control systems and closed all high-quality match for the electrical, intelligent sewage cleaned regularly, wrong phase, short phase, overload current, water shortages protection and fault alarm function. Adopt Sweden 5090-patented technology evaporative wet paper filter net , and the evaporative area in more than 85%; Using 3 leaves impeller, using silencers acoustic and noise reduction technology, the noise can be controlled lower than 56 dB
Airflow(m3/h): 18000 Power(Kw) : 1.1 Voltage/Frequency(V/Hz) : 220/50 Rated Electric Current(A) 2.8/4.8 Fan Type: Axle Discharge Type : up discharge Controller Type : Intelligent LCD Motor Type: Single-phase Various Frequency Speed Unit Size(mm):1080í-1080í-980
The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Parameter specification: Airflow(m3/h):18000 Power(Kw) :1.1 Voltage/Frequency(V/Hz) :380/50 Fan Type:Axle Motor Type:Three-phase Fixed Speed Controller Type :Intelligent LCD Capability characteristic: Injection shell is using modified PP composite materials and aluminum alloy column precision tectonic process; with the easy pull-out filters, wet screens paper of the frame protection and shockproof design, frame bearing capacity of 100 kg and above,with anti-corrosion, anti - ultraviolet, anti-aging15 years, high and low temperature resistance (subzero 20 fp C - 50 fp C) without distortion, and fuselage life for more than 10 years. LCD panel control system, using single-phase various frequency speed, three-phase various speed, three-phase fixed speed intelligent electronic control systems and closed all high-quality match for the electrical, intelligent sewage cleaned regularly, wrong phase, short phase, overload current, water shortages protection and fault alarm function. Adopt Sweden 5090-patented technology evaporative wet paper filter net , and the evaporative area in more than 85%; Using 3 leaves impeller, using silencers acoustic and noise reduction technology, the noise can be controlled lower than 56 dB.
Tzjw-d-101b, tzjw-s-301b, tzjw-d-101a, tzjw-s-301a Carton box
Type:fan coil unit Place of origin:shanghai, china (mainland) The features of the fan coil units 1, motor with low noise, energy saving the fixed packet capacitor with self-lubricating with imported nsk bearings, precision dynamic balancing tuned, smooth operation and long service life. 2, fan ultra-wide-angle volute, multi-blade centrifugal wind wheel, and undergo a rigorous static and dynamic balance test adjust, smooth running, low noise. 3, the gorgeous shape designs, matching with environment diapason;four direction etc.The size design, installing layout is mot vivid;the extremely high degree strong dint sends breeze, also applying all kinds of busines places. Model air volume cooling capacity M3/h cfm btu/h Ck1-mfp-34wa-z 340 200 9000 Ck1-mfp-51wa-z 510 300 12000 Ck1-mfp-68wa-z 680 400 15000 Ck1-mfp-85wa-z 850 500 18000 Ck1-mfp-102wa-z 1020 600 24000 Ck1-mfp-136wa-z 1360 800 28000 Ck1-mfp-170wa-z 1700 1000 36000 Ck1-mfp-204wa-z 2040 1200 48000 Ck1-mfp-238wa-z 2380 1400 60000
Components for chimneys and ventilation systems, made from stainless steel (steel brands aisi 304. 316) and galvanized steel. Diameters for chimneys are in the range 80-1200 mm. The following thickness of chimneys is available: - aisi 304 - 0.5, 0.6, 0.8 and 1.0 mm; - aisi 316 - 0.5, 0.6 and 0.8 mm; - galvanized steel - 0.5 mm. Standard euro pallets, carton or papper, depending on the order.
We are Manufacturer of cold storage, cold room as per customer requirment.We used high quality raw material from renowned manufacturer in India.
The semiconductor refrigeration piece(te modules); thermoelectric cooling module; semiconductor refrigeration piece; thermoelectric refrigeration component Standard packing
FeatureApplications * long life * air purifier * high sensitivity* air quality monitoring * automatic calibration * air ventilation system * comes with temperature & humidity compensation * low cost Spec * module model:Aqm-300c * sensor:Aqs501 air quality monitoring sensor * gas detection: ammonia, hydrogen, alcohol, carbon monoxide, methane, propane, gan alkyl, styrene, propylene glycol, phenol, toluene, ethylbenzene, xylene, formaldehyde and other volatile organic gas, such as cigarettes, wood , paper burning smoke. * physical interface:Xh2.54-4 vertical outlet * output data:Ttl level¡§built-in 200ohm current limiting resistance * input voltage:5.0¡¡.2vdc ¡§without voltage reverse polarity protection * operating current:80ma * warm-up time:2 minutes * response time:10 seconds * recovery time:20 seconds * operating temperature:-10 --- 40 * operating humidity:95µ¶h * storage temperature:-20 --- 60 * storage humidity:60µ¶h * dimension:242015¡§l‡óh * weight :About 20g * sensitivity :1ppm hydrogen * sensitivity reduction:¡¡.2%/year * life:10 years Interface definition 1Power supply negative 2Power supply positive 3Output signal a 4Output signal b Output signal definition ABPollution degree LowLow0 LowHigh1 HighLow2 HighHigh3 Remarks¬hèùåê higher the pollution degree no., the worse the air quality.
1. Introduction: New Air intelligent controller (KF-800F) can monitor real-time indoor temperature, CO2 concentration. Controller output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment. 2. Buttons function 1. button: timing parameter setting 2. button: parameter increase 3. button: parameter reduce 4. button: setting working mode for controller, press this button slightly, the controller will be switched circularly betweenAUTO MANUAL TIMER POWER OFF. 3. Display explana4. Detailed explanation 1. AUTO (auto mode): high speed: CO2 concentration exceeds the setting concentration value of 300ppm; middle speed: CO2 concentration exceeds the setting concentration value of 100ppm; low speed: CO2 concentration exceeds the setting concentration value; stop: CO2 concentration is below the set concentration value. 2. MANUAL: set the ventilator as OFF(stop)LOW(low speed)MED(middle speed)HIG((high speed))by buttons and , and under this mode, the ventilator will run according to the setting, won¬H be affected by CO2 concentration. 3. TIMER (timing mode): run according to set time & speed, can set from Monday to Sunday, 4 periods every day, and 28 periods in total. 4. Automatic mode Cconcentration value setting when the ventilator starts: under the auto mode, press or button for one second, it will appear CO2 concentration setting value and flicker, then press and buttons to change the number (from 350 ¡§C 600ppm). Controller will return to normal working condition and save setting parameter automatically if you won¬H press any buttons more than 10 seconds during the setting process. 5. Timing parameter setting: press button for 2 seconds to enter parameter setting. First enter ¡ãlocal time adjust¡À, press button to switch week, hour and minute, the corresponding parameter will flicker, change the number by and buttons; after finishing adjusting local time, press button to enter the first period hour setting on Monday, press button to switch hour, minute, and ventilator speed, press and buttons to change the number. After finish the setting, press button to enter the second period hour setting on Monday. Repeat above steps to finish all the 28 periods setting. Controller will return to normal working condition and save setting parameter automatically if you won¬H press any buttons more than 10 seconds during the setting process. 6. Backlight: CO2 concentration less than 500ppm (green backlight), 500-799ppm (yellow backlight), higher than 800ppm (red backlight).
1. Introduction: New Air intelligent controller (KF-800E) can monitor real-time indoor temperature, humidity, VOC concentration. Built-in air quality sensor can monitor ammonia, formaldehyde, benzene, xylene, hydrogen, alcohol, carbon monoxide, methane, propane, Gan alkyl, styrene, propylene glycol, phenol and other Volatile organic compounds as well as wood, paper, cigarette smoke and a dozen combustion gasesController output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment. 2. Monitoring objects 1. Volatile organic compounds (VOC) concentration¡¡100ppm Real-time monitoring indoor air whether including formaldehyde, benzene, ammonia, hydrogen, alcohol, carbon monoxide, methane, propane, Gan alkyl, styrene, propylene glycol, phenol, toluene, ethylbenzene, xylene and other volatile organic gas, such as cigarettes, wood , paper burning smoke or not. 2. Indoor temperature: 0---- +50 3. Indoor humidity: 5 H----95%RH 3. Function & Feature: 1. Real-time display indoor concentration of volatile organic compoundsVOC) 2. Display the current indoor air pollution levels 3. Real-time display the indoor temperature 4. Real-time display indoor humidity 5. According to temperature, humidity and VOC concentrations, automatically adjust the ventilator operation 6. Display the new air system ventilator statusStop, slow, medium and high speed, working modeManual, automatic, timing 7. Automatic mode±bè ` the intelligent controller detect indoor air quality become worse, the new air system can automatically adjust the ventilator speed 8. Manual mode e can control the startup & speed of ventilator by ¡ãmode button on the controller panel or ¡ãRF remote control
1. Introduction: New Air intelligent controller (KF-800M) can monitor real-time indoor temperature, CO2 concentration. Controller output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment. 2. Buttons function: 1. button: timing parameter setting 2. button: parameter increase 3. button: parameter reduce 4. button: setting working mode for controller, press this button slightly, the controller will be switched circularly between AUTO MANUAL TIMER POWER OFF. 3. Display explanation: Time Indoor temperature CO2 concentration Heating switch mode Operating mode Ventilator status 4. Detailed explanation 1. AUTO (auto mode): high speed: CO2 concentration exceeds the setting concentration value of 300ppm; middle speed: CO2 concentration exceeds the setting concentration value of 100ppm; low speed: CO2 concentration exceeds the setting concentration value; stop: CO2 concentration is below the set concentration value. 2. MANUAL: set the ventilator as OFF(stop)LOW(low speed)MED(middle speed)HIG((high speed))by buttons and , and under this mode, the ventilator will run according to the setting, wonH be affected by CO2 concentration. 3. TIMER (timing mode): run according to set time & speed, can set from Monday to Sunday, 4 periods every day, and 28 periods in total. 4. Automatic mode ¡ìCconcentration value setting when the ventilator starts: under the auto mode, press or button for one second, it will appear CO2 concentration setting value and flicker, then press and buttons to change the number (from 350 ¡ìC 600ppm). Controller will return to normal working condition and save setting parameter automatically if you wonH press any buttons more than 10 seconds during the setting process. 5. Timing parameter setting: press button for 2 seconds to enter parameter setting. First enter šÑ�N’“ã¸šÑ time adjust, press button to switch week, hour and minute, the corresponding parameter will flicker, change the number by and buttons; after finishing adjusting local time, press button to enter the first period hour setting on Monday, press button to switch hour, minute, and ventilator speed, press and buttons to change the number. After finish the setting, press button to enter the second period hour setting on Monday. Repeat above steps to finish all the 28 periods setting. Controller will return to normal working condition and save setting parameter automatically if you wonH press any buttons more than 10 seconds during the setting process. 6. Backlight: CO2 concentration less than 500ppm (green backlight), 500-799ppm (yellow backlight), higher than 800ppm (red backlight). 5. Specification