Compatible with OpenTrons OT-2 exactly Stackable pipette tips Proof static electricity affordable, replaceable to orignal brand
Rainin tips, aerosol filter pipet tips for Rainin, LTS pipette tips, micro pipette tips, Rainin LTS tips,
I sell drinking water in glass bottles 0.33ml and 0.75ml. The water is of high quality and with certifications for pregnant women, the distribution of children's food, etc. Contact us for any type of order with any type of capacity.
4. Performance specifications 1. Temperature range: RT+40 -70 2. Humidity range: 90% RH 3. Temperature control accuracy: ± 3 *Note: The performance guarantee of item # 5 above requires testing at a distance of 1/6 of each wall surface in the testing area, and must be measured after stabilizing with temperature and humidity for 30 minutes 4. Equipment placement space: at least 207 two hundred and seven 201cm (W H D) 5. Power supply: AC220V 50HZ 5 System structure 1. Heating system: Scaled stainless steel electric heating tube 2. Humidification system: glass nozzle 3. Temperature sensing system: Made of stainless steel SUR304Pt100 4. Control system: The control system adopts a P.I.D controller, which controls temperature and humidity simultaneously a. Controller specification: Accuracy: Temperature ± 2.0 +1 digit, with upper and lower limit standby and alarm functions 5. Box material Inner box material: SUS # 304 mirror stainless steel plate Outer box material: SUS # 304 stainless steel plate
model Basic parameters DL-60 DL-90 DL-120 DL-160 DL-200 Dimensions inside the test chamber (Long �? wide �? High) 600*450*400mm 900*600*500mm 1200*1000*500mm 1600*1000* 500mm 2000*1200* 600mm Test chamber volume 108L 270L 600L 800L 1440L Volume of brine tank 15L 25L 40L 40L 40L Laboratory temperature NSS ACSS 35�±1â??ï¼?CASS 47�±1â?? Pressure barrel temperature: NSS ACSS 47�±1â??ï¼?CASS 63�±1â?? Brine temperature: 35â??�±1â?? Spray mode Ordinary type without suffix letter, economical type (M) continuous spray (A), programmable spray (B) Spray volume: 1.0ï½?2.0ml/80cm2/h(Different mist collectors need to be converted according to this ratio) Spray pressure 1.00+0.01kgf/cm2 source AC 220V 10A AC220V 10A AC220V 16A AC220V 16A AC220V 16A
2.Technical parameters: 1. Box size in the laboratory: DL-120LA W1200 * D1000 * H500 (mm), Approximate dimensions: 2300 * 1300 * 1400mm, 2 standard temperatures, Laboratory temperature: nss acss 35 ± 1 /pass 50 ± 1 Pressure bucket humidity: nss acss 47 ± 1 /pass 63 ± 1 , Salt water temperature: 35 ± 1 It can be heated without water, 3 volumes, Laboratory capacity: 800L Salt water tank capacity: 40L, 4 compressed air, Compressed air pressure: 1.00 ± 0.01kgf/c 5 spray volume: 1.0-2.0ml/80c /h, 6 spray mode: continuous spray, timed spray, programmable spray, intermittent spray, demisting in the box, 7. Power supply: AC220V 50Hz/20A, 8. Material: The entire PVC board is made, and the salt spray testing machine adopts advanced three-dimensional reinforcement technology internally, with a strong and solid structure that never deforms. 9. Water adding method: An automatic water adding system is adopted, which has the function of automatically replenishing the water level when the water level is insufficient, and the test is not interrupted. 10. Nozzle: Precision glass nozzle, salt spray testing machine used for 4000 hours to ensure no crystal blockage. 11. Protection system: Equipped with dual over temperature protection and insufficient water level warning to ensure safe use. 12. Temperature controller: digital display, PID control, high stability platinum temperature probe, error 0.3 13. Heating method: The laboratory adopts direct steam heating method, which increases the temperature quickly and shortens the standby time of the salt spray testing machine. 14. The spray tower is equipped with two conical dispersers, which have the functions of guiding fog, adjusting fog volume, and even fog falling. 15. The pressure bucket adopts Henry's law to heat and humidify, and provide the humidity required by the salt spray testing machine laboratory. 16. Opening method: Pneumatic automatic opening is adopted, The salt spray testing machine is one of the "three prevention" (humid heat, salt spray, mold) testing equipment for artificial climate environments. It is an important salt spray testing equipment for studying the adaptability and reliability of various environments in industries such as machinery, national defense, light industry, electronics, light industry electronics, and instruments. This salt spray testing machine can perform neutral salt spray tests in accordance with GB/T2423.17 "Basic Environmental Testing Regulations for Electronic and Electrical Products - Test Ka: Salt Spray Test Method", and can also perform acetate spray tests. This salt spray tester complies with CNS, ASTM, JIS and ISO standards. The salt spray test is to test the corrosion resistance of the products after coating, electroplating, Anodizing, anti-rust oil and other anti-corrosion treatments on the surfaces of various materials.
1.)Performance specifications: 1. Machine model: DL-4100, 2. Capacity: 100L, 3. Temperature range: -40 -150 , 4. Humidity range: 20% -98% RH, 5. Temperature and humidity control accuracy: ± 0.5 ± 2% RH, *Attention: The performance guarantee of items # 2-4 above should be measured after 30 minutes of stable temperature sensing 6. The temperature and humidity are evenly distributed: ± 2.0 ± 5.0% RH, *Note: The performance guarantee of item # 5 above requires testing at a distance of 1/6 of each wall surface in the testing area, and must be measured after stabilizing with temperature and humidity for 30 minutes 7. Inner box size: 500 high Width 400 500mm deep, 8. Outer box size: 1700 high Width 1000 1500 mm deep, 9. Equipment placement space: at least 2000 2000 2000mm (W H D) , 10. Power supply: AC220V 4.5KW, 50HZ
Product introduction: HAST (Highly Accelerated Stress Test) is a type of test that is used to evaluate the reliability of electronic components and other materials under high temperatures and humidity. A HAST test chamber is a device that provides controlled conditions of high temperature and humidity to simulate the effects of aging and degradation on materials over a shorter period of time than would occur in normal use. During testing, the sample to be evaluated is placed in the HAST chamber, which is then heated to a high temperature and subjected to a high-pressure steam environment. The temperature and humidity levels are carefully controlled to ensure that the sample is subjected to the appropriate conditions. The purpose of the HAST test is to identify any weaknesses or defects in the material that may cause it to fail prematurely in real-world use. By exposing the sample to accelerated aging conditions, engineers can evaluate the long-term reliability of the material and make any necessary improvements to its design. HAST test chambers are commonly used in the development and testing of electronic components, such as integrated circuits, printed circuit boards, and semiconductor devices. They are also used in other industries where materials must be able to withstand harsh environmental conditions, such as the aerospace, automotive, and medical device industries.
Plastic Tips for 10 ul, 200 ul, 1000 ul etc.. Optional with sterile, filter, length etc..
Lab Filtration
Labware
Lab Instruments
Bench-top Type Temperature(&Humidity) Test chamber: The Bench-Top Type Temperature Humidity Chamber most ideal designed for temperature and humidity testing of small samples and specimens used for research, development and quality control. Daily necessities, cosmetics, electronic components, and medical products must meet certain quality standards and testing specifications. That size that can fit on a personal desk is the most consideration. Features: 7inch big PLC touch screen color display for easy operation Temperature Humidity control and display unit Safety protection system Desk top, Table top, Bench Top Fit
UV accelerated aging test chamber can simulate environmental conditions such as self-climate ultraviolet rays, rain, high temperature, high humidity, dew condensation, darkness, etc. By reproducing these conditions, it is merged into a cycle, and it automatically executes the number of cycles completed. In this process, the equipment can be used for automatic monitoring of blackboard temperature and water tank temperature; by configuring irradiance measurement and control device (optional), the irradiance can be measured and controlled, and the irradiance is stable at 0.76W/m2/340nm or specified setting. Fixed value, greatly extending the service life of lamps.
Climatic Temperature Humidity Test Chamber provide constant humidity and heat, complex high and low temperature alternating and other test environment and test conditions for electronic components, industrial materials and finished products in development, production and testing processes, applicable for electronic appliances, telecommunications, chemicals, hardware, rubber, furniture, toys scientific research etc.
A small selection of common laboratory consumables such as filter tips. DaklaPack can also provide you with many common everyday laboratory consumable items. Cant find what you are looking for in our webshop? contact us today - we can probably source it for you through our wide network of business partners. - Bloodlabel 10 - Tempmate - Temperature adhesive strip - Vial opener - Cotton balls - Filter tip sterile
NG500 lab use nitrogen generator Product Description NG500 Nitrogen Generators Lab nitrogen gas Working Principle Nitrogen generator uses the electrocatalysis method to separate air gas Stable and pure air enters electrolysis cell and oxygen in the air is separated then left nitrogen gas is outputted Application Carrier gas for various brands of GC and GCMS Make up gas for GC Supplementary gas 3Gas for Gel Permeation Chromatograph 4LCMSLiquid ChromatographMass Spectroscopy and Thermal Analyzer 5Other field that ask pure N2 Features 1 Program control Nitrogen gas could be adjusted automatically according to usage flow under stable pressure and flow 2 Advanced technology It uses noble metal as catalyst high catalytic efficiency and large nitrogen production 3 Twolevel catalysis Oxygen content in nitrogen is less than 3ppm 4 Lower moisture in nitrogen gas Technical Parameters Model NG300 NG500 Output Flow mlmin 0 300 0 500 Output Pressure 042 Nitrogen Purity 99999 compared with O2 Input Air Pressure 04 Power Voltage V 22015Â 50 60Hz Input Power W 110 200 Weight kg
1. Tetrafluoro flasks have single-neck, three-neck and four-neck, 17, 19 and 24 standard ports, and each standard port is equipped with a stopper. 2. It can be disassembled and cleaned, and the inner wall is smooth; 3. Operating temperature: -200+250 4. PTFE round bottom flasks can be processed according to your requirements; 5. The cover and the body, as well as the necks and the cover are connected by threads, which is convenient for disassembly and cleaning
*Description* This rovings Fiber Glass is a high-tech reinforcement for long fiber polyamide (PA) processes such as granulate long fiber thermoplastic (GLFT) and direct long fiber thermoplastic (DLFT). This rovings offer a hydrolytic stability in high performance applications. Each package is in a wrap film with each pallet stretch wrapped to protect the fiber glass roving from dirt and moisture. *Processing advantages* Excellent spreadability of the roving filaments in thermoplastic pultrusion allowing complete resin impregnation. Sizing on the fiber surface has been tailored to provide optimal balance of dry strength, fiber resin wetting and minimal sizing rub-off on process contact points. Available in outside and inside payout. Excellent processing in pultruded GLFT processes for molding of high performance long glass PA end products. Excellent wet out and saturation in polyamide (PA) resin. Highest mechanical as-molded properties with best-in-class long-term hydrolytic stability. KOHLI POLYMERS GMBH
The inner surface is smooth, high transparent and straight with high accuracy. Both normal and low-retention are available for customer to choose. 10 UI Medical grade