Luminaires are used for lightning of:
Outdoor and indoor lightning facilities with emergency (reserve) lightning Housing of luminaires is made of aluminum alloy. ptics
borosilicate glass or polycarbonate. Luminaires have anti-vandal
protection. Different types of mounting allow to install luminaires without improvement of the existing mounting attachments.
Thermal break, energy saving aluminium profiles, minimas design. Wide range of products for all architectural application suitable. New innovative aluminium system with more visible glass surface. All ral colours available, quick deliveries, competitive prices, high quality products, perfectly fit constructions
Thermal break, energy saving aluminium profiles, minimal design. Wide range of products for all architectural application suitable. New innovative aluminium system with more visible glass surface. All ral colours available, quick deliveries, competitive prices, high quality products, perfectly fit constructions
Superkit advantages:
Rugged, all stainless steel design is the toughest available.
This is a complete, fully assembled kit that features a built-in reservoir design. No need for an additional reservoir/bubbler.
Extremely efficient electrode design maximizes hho, offers cool operation and requires only 10-25 amps, so there is no need of an automotive wiring relay.
Metal enclosure provides excellent safety characteristics and does not melt.
Industry leading heat dissipation allows operation without expensive cooling systems.
Completely sealed design for reliability and simplicity of operation.
Refill port allows to easily add more water without removing the generator from the car.
Designed for reliability and simplicity of use.
Full range of electronic accessories compatible with any hho system to optimize your set up.
This kit includes:
Superkit hho generator with efficient stainless steel electrode pack (already installed in generator)
5 feet of top quality, braided reinforced tubing
Flashback arrestor
Fusible link (fuse and holder)
10 feet (16 gauge) red primary hook up wire (for 12 volts)
5 feet (16 gauge) black secondary hook up wire
1 illuminated toggle switch
3 female spade, “quick disconnect” connectors for connecting to the toggle switch
Comprehensive, yet easy to understand instruction manual
Physical size: 10 inches tall and 4 inches wide
Usually we ship at 3 day after receive clear payment
LMZ designs the best proper Mobile Substation by analyzing customer requirements, site and transportation conditions.
SETAS Mobile Substations are used for military camps, industrial facilities, distribution networks, emergency power demands and additional power requests.
Mobile Substation General Specifications:
HV switching equipments can be gas ORA IR insulated
Trailer / Platform / Wagon / Vessel type applications
Up to IP 56 Protection Class
Entire substation can be deliver being ready to use in a SCADA system
Shorter manufacturing time compare to fixed type.
Ideal solution for emergency power demand, temporary services and new services
Production is made according to IEC 62271-202, 200, standards, different standards can also be applied on demand.
3 phase mains and 3 phase generator voltage measurement,
3 phase load current and earth current measurement,
Contactor open and close relay outputs for mains and generator,
Configurable 6 inputs and 4 outputs,
3 resistive sender inputs for oil pressure, temperature and level,
Stop or fuel selenoid selection,
Programmable weekly working permit calendar,
Maintenance warning (working hour or elapsed month),
Exercise at programmed time intervals,
Off, manual, auto and test mode,
Power measurement by kva, kw, kvar, kvah, kwh, kvarh,
Compatible to diesel or gas generators
* sends sms to pre-defined gsm numbers for alarms
* controls the generator and monitors status information of the generator by sms
* remote control via internet, intranet, gsm or dial-up modem
* access to multiple generators by gen-agent scada software
* authorised access, secure communication
* suitable for telecommunication projects
* automatic transfer switching control and engine control
* logs last 32 events & alarm informations
* full metering facility, energy and power measurement
Maximum AC Output (kVA) : 1.2
Prime Power / kVA (kW): 0.9
Rated Current (A) : 4
DC Output : 0
Output Voltage (Volt): 230
Frequency (Hz): 50
Power Factor ( Cos +): 1
Automatic Voltage Regulator : +
Large Capacity Air Cleaner : 0
Large Capacity Muffler : +
Oil Alert : 0
Voltmeter : +
AC Circuit Breaker : +
DC Circuit Breaker : 0
Fuel meter : 0
Battery : 0
4 wheel dolly kit : 0
Dimensions LxWxH (mm) : 410x305x350
Dry Weight (Kg): 23
Easy lifting and moving (Optional)
Metal parts are coated with electrostatic polyester coated, powder painted
Acustic insulation with rot-proof, moisture repellent and non flammable material.
Co-generation plant
Bv cogeneration boilers: boilers for production of steam or heating of other fluids by harnessing the heat of the combustion gases from turbines or alternative motors for producing electricity.
These units are designed in accordance with the characteristics of each plant.
Models with auxiliary burners are also manufactured.