LED Module For Convenient Replace, ,Intergrated LED Module
LED Module Used For Landscape Light, ,Intergrated LED Module
Electrical parts Pls. Send inquiries with corresponding oem no. Or manufacturer no.
Controller Uhp03smartnet is a 4 channel universal controller. It is intended for solving engineering tasks of average and high difficulty. It contains a wide periphery of inputs/outputs, graphic display and convenient operator interface. Apart from configuration of the device, the controller software also allows the user to record the configuration and test the device. The controller is compatible with scada. Device structure permits development of a console of devices, the number of which depends on the respective application thereof. Overview Analog inputs v 4-adc16b Input signals - pt100, cu53; tc-j, k, s, t; 4 v 20ma 4 regulators v on/off; 3 regulators pid - autotun Proccesindicator Totalizer Digital inputs - 4 Communication rs232/485/422 Protocol - modbus rtu Analogous output v 2 Relay output - 4 (6a/250v) Power suply - 85-265 v ac/dc Realtime clock Compatibility - scada Lcd display monochrome - 128 x 64 Number of operator screens - 9 Config software 96x96x119
Annunciator module Lsb40r is a 39-channel annunciator for technological signalization, intended to draw attention of on-duty operators in command halls in the event of accidents, emergencies or other situations that require their operative intervention. It is compatible with scada. It is applicable for panels at an average distance from the operator and joint management (hardware and software). The tape is suitable for installing in a board or panels/desks. 160x560x60
Firewood, pellets from sunflower husks, bran and straw; briquettes from corn straw etc.; e bikes; small wind turbines.
Navigation equipment and satellite communications VHF/VHF DSC MF/HF AIS EPIRB/SART GPS INMARSAT/SSAS X/S BAND RADARS VDR SPEEDLOG ECHOSOUNDER BNWAS AUTOPILOT/GYROCOMPASS
3115 1582 00 - Driver
Please see our catalog on our website.
PRO-EARTH is produced to reduce earth resistance, improve grounding effectiveness and impedance measurements. Has non-corrosive and bentonie based structure and Installed in all soil conditions.
WL1831MODGBMOCT 1100 in stock Category: Hot Parts Tag: Texas Instruments
Toshiba 32WA2063DG HDR Android
557/60210 Ram assembly, bucket 90 x 60 JCB product numbers are for reference purpose only.
The insulators testing device HVTS-HP is designed for testing the insulation of power cables and solid dielectric with the rectified voltage of up to 100 kV, as well as testing solid dielectrics with the sinusoidal voltage of up to 100 kV, 50 Hz. The main difference between series devices Cable test and diagnosis system HVTS-HP devices from Portable Hi pot Tester HVTS-70/50 is the increased power output. There are two standard versions: 7.5 KVA and 17.5 KVA.
SWG-12 Mobile Cable Test and Fault Location System - is a complex solution for safe, fast and easy locating a faulty place on low and medium underground voltage cables. It includes a powerful high-voltage unit, which has a test, burn and surge generation modules, and a time-domain reflectometer for locating faults on cables. Main features: - Suitable for portable application - Easy to operate - Multiple fault location methods included - 10.4 High-contrast color TDR display - Improved convenience for operator - Heavy duty The high-voltage unit of the system provides with high-power up to 1100 Joules surges at 3; 6 and 12 kV ranges. At each range, the output voltage is smoothly adjustable. The rate of surge waves can be smoothly adjusted. The single manual shot option is also included. The DC output mode is provided for quick fault diagnostics. The 100 mA burn mode is available. Digital Impulse Reflectometer (TDR) provides you with 10.4-inch bright high-contrast TFT display with touchscreen. The 800 Ã? 600 pixels resolution makes the picture sharp. The touchscreen allows an operator navigate through the menu fast and easy. An alternative way of navigation is included. It is provided with a control knob. Reflectometer RIF-9 integrates a multiple ways of fault prelocation. It can be used either as a standalone device in TDR mode or in a conjunction with HVmodule, working in arc reflection mode. Reflectometer RIF-9 has USB interface. The package content includes software for PC (optional), which allows working with saved reflectograms. The firmware can be easily updated through USB interface by inserting a flash drive.
Ballastco presents all capacities of lighting capacitors for gas discharge lamps. Ballastco lighting capacitors are used for compensation of fluorescent, sodium vapor, mercury vapor and metal halide lamps' power factors.......... From 18 watt up to 2000 watt gas discharge lamps ballastco lighting capacitors can be safely used....... Applications Sodium lamps.... Halogen and metal hallide lamps.... High pressure mercury vapor lamps..... Low pressure mercury vapor lamps..... Fluorescent lamps..…
Product Code BI 5004-1 BI 5004-2 BI 5004-T BI 5005 BI 5006 Lamp Type (W) : HPS 70-150 HPS 70-400 HPS 70-400 HPS 1000 MH1000 MH 35-150 MH 35-400 MH 35-400 MH 1000 -2000 Input Voltage (V) : 220-240 220-240 220-240 220-240 220-240 Frequency (Hz) : 50-60 50-60 50-60 50-60 50-60 Ignition Voltage (kV) : 1,8-2,5 4-5 4-5 4-5 0,7-1 Half Wave Pick Number : 3 3 3 1 1 Max. Lamp Current (A) : 2 5 5 15 15 Loading Capacitor(pF) : 20-300 20-300 20-300 20-300 20-300 Cut out Voltage (V) : 185-198 185-198 185-198 185-198 185-198 Switch-off Time (min) : ... ... 5-10-20 ... ... Max. Temperature(°C) : 105 105 105 105 105 Min. Temperature(°C) : -30 -30 -30 -30 -30 Weight (kg) : 0,13 0,13 0,13 0,13 0,13 APPLICATIONS For use with HPS and MH lamps Outdoor lighting luminaries Road & street luminaries Stadium and sport complex lighting luminaries Industrial luminaries Decorative lighting luminaries Gas station luminaries PRODUCT FEATURES Provides ignition at lamp pick voltage of 198 V Goes of from the circuit as the ignition done Stops ignition as ballast pick voltage decrease under 185 V Time adjustable options which improves ignitor, ballast and lamp lifetime Makes ignition in cooling time in the case of power cut Resistant to heat, moisture and mechanical impacts
Our Product Range of Constant Voltage LED Drivers; Product Code Power (W) Output Voltage(Vdc) Output Current(A) Tolerance Efficiency Dimension (L*W*H) Weight (Kg) BLDV-6-5 6 5 1 3% 78% 68*33*22 mm 0,045 BLDV-6-12 6 12 0,5 3% 80% 68*33*22 mm 0,045 BLDV-12-5 12 5 2,0 3% 80% 88*38*22 mm 0,065 BLDV-12-12 12 12 1 3% 84% 88*38*22 mm 0,065 BLDV-12-24 12 24 0,5 3% 86% 88*38*22 mm 0,065 BLDV-24-5 24 5 3 3% 82% 110*42*25 mm 0,095 BLDV-24-12 24 12 2 3% 84% 110*42*25 mm 0,095 BLDV-24-24 24 24 1 3% 86% 110*42*25 mm 0,095 BLDV-36-12 36 12 3 3% 86% 145*45*30 mm 0,15 BLDV-36-24 36 24 1,5 3% 88% 145*45*30 mm 0,15 BLDV-60-12 60 12 5 3% 86% 155*45*30 mm 0,185 BLDV-60-24 60 24 2,5 3% 88% 155*45*30 mm 0,185 Product Features High quality terminal outputs High efficiency Wide range of input voltage(170-260Vac) Short circuit protection Over Current Limitation Thermal protection with hysteresis Minimum standby power consumption (
VLF-60 Cable Insulation Tester by KEP is a very low frequency high potential tester that ensures efficient testing and fault location on medium voltage cables. Testing principle Very low frequency (VLF) testing involves applying frequency in the range of 0.01 to 0.1 Hz to the cable under test, which is non-destructive to insulation of proper quality, but is enough to detect cable faults. Compared to DC cable testing, which can be damaging to good insulation, VLF testing does not have such a detrimental effect on the cable being tested and does not generate any travelling waves. Main features Efficient non-destructive cable withstand testing Portable, perfect for field testing Fully automatic testing cycle Automatic discharging Easy maintenance due to solid-type insulation system Breakdown voltage measurement and load recognition Easy-to-use software Does not need an external PC LCD touch screen
Pre-owned CT Scan System with Standard Accessories â??As is â??in Working Condition YOM: 2013 Software: VB42B Tube Type: MCT_172 Tube Scan Seconds: 152,162 Tube Replaced: In September, 2020