All fittings are manufactured to comply with the Electrical Equipment (Safety) Regulations 1975/76 and comply with BS4533. Standard fittings are fitted for the use on 240v 50Hz supply, all fittings are individually tested during assembly to ensure excellent quality and reliability.
The unmistakable design is reminiscent of the actions of the barista and espresso that you make at home is just like those in the bar with a constant and perfect extraction quality : you do the capsule in the filter holder and put the issue on with one button press . That is iperEspresso . With soft-touch buttons. He has a steam pipe for cappuccino : the wait time between switching from coffee to cappuccino function is minimal
CEE Plug connections from ABL SURSUM have safety standards that we are proud of - even under the toughest of conditions.
They impress with innovations and maximum technical efficiency right down to the last detail. That is how they make our products into solutions for the most demanding challenges. Screwless, centric strain relief, double-secured box terminals, highly-conductive lamellar contacts and self-finding threads are only some of the most important details that not only experienced professionals can appreciate.
It can happen very quickly: Thoughtlessly touching a currentcarrying cable; a faulty connecting cable; or a device fault. Happy are those who have protected their electrical system with the right RCCB. In the event of damage, it is activated within a fraction of a second, breaks the circuit and thus possibly saves lives. In this way, everyday exposure to current gets considerably safer.
For new installations and extensive renovations of commercial and private electrical systems, the use of RCCBs is mandatory according to VDE 0100-410 since June 2007 anyway. This also refers to all outdoor electrical systems and electric circuits.
Our product range offers you the right RCCB solution for every field of application because - in addition to devices of type A (sensitive to pulsating currents) and type B (sensitive to universal current) for the German market - we can also deliver devices of type AC (sensitive to alternating current - not approved for Germany) for export.
Two connection variants with screw terminals and in various colours.
With screwless terminals (plug2power), with and without higher protection cover, in SCHUKO versions and in accordance with the French/Belgian CEE 7/V) standard.
In addition to the high safety standards for the CEE components used and the high-performance Miniature circuit breakers, these Wall-mounted socket outlets have a mechanical locking system for optimal safety.
Wall-mounted socket outlets which can be switched off - everything under control in one step.
* Enclosure in PC/ABS version
* Mechanical locking: after insertion and switching on, the plug is locked after switching off and removal of the plug, the switch is locked
* On/Off switch 10kA accordance to EN 60947-3
* Large connection space
* Wired
* Cable entry above or below
* Wide number of versions from 16 to 63A can be supplied
* Wiring can be led through for 16 A and 32 A
* Can be locked with padlock (40 mm) in the switched-off position
* From wiring space, protected long hole wall mounting.
- Automatic and power control relays
- Time relays
- Relays and protector and alarms of single-phase circuits on ground in circuits 6-10 kV
- Relay protection and automatics
- Phase control relays, isolation and pulsation
- Electromagnetic relays.
Totally two identical 145 kW wind turbine units, made in 1988 by Danish A/S Nortank, total operating hours approx 75000. The equipment have been dismatled since 2008 and inspected and serviced for operation condition and they are ready for immediate delivery
We have totally 2 units of uninstalled complete wind turbines manufactured by Danish A/S Nordtank in year 1988, manufactures type NTK 130 with rated power of 2 x 145 kW. The mills are in good operational condition and ready for immediate shipment. The hubs are heat treated MEEHANITE hubs made by company SABROE and are equipped with cast iron construction which allows adjustment for blade pitch angle. The blades are made by Danish company LM- Glasfiber, material is glass fiber reinforced polyester and they have self-supporting structure with bushing roots. The blades have also hydraulically activated tip brakes which automatically rotate the tips to a 90 degree break angle when wind is lost or it can be used for maintenance stoppage. The gear box in made by German Lohman & Stolterfoht and it is two step planetary gear type with high AGMA rating of 302 kW. The break system is 100% fail safe Nortank’s own hydraulically / mechanically activated brakes. Both units have they own Motorola 6809 multi-microprocessor operated control units which are housed in dust proof steel cabinets.
More information on requests, for spam protection please introduce yourself properly.
Main data of one mill:
Manufacture’s type: NTK 130F/LM
Year of manufacture 1988
Total operating hours: approx. 75000
Rated capacity, max: 145 kW
Number of blades: 3 pcs
Rotor diameter: 22 m
Rotor speed: 44.5 rpm
Cut-in wind speed: 4.0 m/sec
Cut-out wind speed: 53 m/sec (120 mph)
Hub height: 26 m
Generator: ASEA 145 kW / 1500 rpm / 50 Hz
Blade type: LM 9.7 m H/H/T diam. 21 m
Gear box type: Lohman & Stolterfort GPC 145
Clutch type: Lohr & Brokamp Universal Joint No 105
Total weight: 15200 kg.
Caracteristicas Técnicas :
Ancho / Width X Largo / Length X Alto / Height : 180 X 280 X 380
Peso / Weight : 6Kg
Voltage / Weight : 230V/110V/220V Frecuencia / Frequency : 50Hz / 60Hz
Fases / Phases : 1(monofásico / Single phase) - Rpm: 1300 / 1600
Intensidad / Current : 1, 3 A / 2,7 A - Condensador / Condenser : 8nf / 40nf
Potencia / Power : 0,10Hp / 270W
Grado de protección / Degree of protection : IP21
Motor provisto de protector térmico / Motor equipped with thermal protector
Tiempo máximo de funcionamiento continuo / Maximum continuous operation time : 30 min.
Paro / marcha versión estándar : arranque manual /ON/OFF, standard version: Manual start-up
Diseñado bajo directiva 89/392 CE / Designed according to EC directive 89/392.