2019 GE Signa Artist 1.5 T Number of Channels 64 Current Helium Level: 88.81% Coils: 1.5T HD Flat GEM Breast Coil, 1.5T GEM Head & Neck , 1.5T 40 Ch GEM Posterior Array , 1.5T 15 Ch Anterior Array , 1.5T 16 CH Large Flex , 1.5T 16 CH Medium Flex Coil 1.5T Split Head Coil Functional condition All functions fully working. Cosmetic condition Excellent condition
Siemens Magnetom Essenza 1.5T MRI 2017 8 RX Channel Enabled Dot Engine Gradient Model: V Software NUMARIS/4 syngo MR D14 Coils: Head Matrix, Neck Matrix, 4ChFlexLarge, 4ChFlexSmall, Body, Body Matrix, Fix Spine Matrix,
Philips Achieva d_Stream 1.5 T MRI Year: 2008 Upgraded in 2015 Cold Head model: Sc-R8 Software Version: R5.6.1.3 Coils: DS Shoulder 8 CH, 2 X DS Anterior 1.5T, dS Flex Large, dS flex small, dS Base 1.5T, dS Head 1.5T, Head Neck 1.5T, FootAnkle 8Ch, SmallExtr 8Ch
*Hitachi Airis II Comfort 0.3T MRI*_ YoM: 2006/ 2007 Colis: 6 spinal coils joint coil Head coil knee coil Body coil
Toshiba Vantage Titan 1.5T MRI Year: 2011 Magnet is professionally ramped down. Available as a full system as well as a parts system.
TOSHIBA Asteion Super 4 TSX-021B 2008 TUBE Model: CXB-400C Last Tube change : March 2019 Tube Usage: 78.615 sec
2008 Toshiba Activion 16 Slice CT Scanner Tube Change: June 2019 Slice Time : 224022 Exposure Count : 239650 D_PRT_COLOR, FAT_MEASURE, INJECTORSYNC, MULTIVIEW, PRINT_SCU, QDSCAN, REALEC, REAL_PREP, REAL_VIEW, STRG_SCU, TIFF, TSB_DVD, WINPRT ALATO_3DVIEWER, ALATO_FLYTHROUGH, ALATO_MULTISLICECT, ALATO_STANDARD, DCM_CDR, DIM_EXP, D_PRT_BW,
Toshiba Aquilion 64 Slice February 2010 Tube Model:CXB-750D Tube Year: 02/2020 Tube Change Date : 24 March 2023 Exposure Count : 161,720 Software: Version: V6.0 BaseV11.2
Siemens Definition AS128 Year: 2010 Water cooling system Tube Model: Straton MX Tube year: 12/2021 Tube Counts: 266030 Patient Table model: PHS3 Workstation Model: Celsius M470â??2 Power/ software version: Syngo CT2012BVA44A
TOSHIBA Aquilion Prime 2011 Tube Year; 2023/11 Slice time :193,061 Exp count : 200,390
PHILIPS Brilliance 16 Slice CT scanner Year: 2009 Software version; V2.3.5. Software option key; please kindly see attached Tube model; CTR2150 Tube MOD; May 2018 Tube usage; 431,787- second (as of Oct. 23) Detector modelï¼?16 slice module ; DMS SINGLE ADM
TOSHIBA Aquilion RXL 16 slice CT Pre-owned CT Scan System with Standard Accessories â??As isâ?? in Working Condition Year of Manufacture: 2012 Tube CXB-750D/4AI: Changed on 17th October, 2022 339,505 scan sec. as of 23rd October, 2024 Software Version: V4.86JR008
Siemens Definition AS+ 128 slice Pre-owned CT Scan System with Standard Accessories â??As isâ?? in Working Condition Year of Manufacture: 2012 Tube: Changed on 2nd March, 2020 548,934 scan sec. as of 14th November, 2024
Siemens Biograph 16 PET CT Year: 2007 Water Cooling System scan seconds 1.62859e+006 Detector Year: 2007 Tube Model: Dura_532 Tube year: 10 / 2013
Siemens Definition Flash 256 Slice CT Year: 2015 Water Cooling Tube Models: Straton First Tube Installation & Scan Seconds: : 06/2021 - 162,966 Second Tube Installation & Scan Seconds:01/2022 - 9,431
Toshiba Aquilion 64 CXL CT Scanner YOM 2012 Tube replaced Jun.2023 Tube slice time 330,247 sec Tube model CXB-750D Software Version V4.86JR015
GE Discovery 750HD 128 slices CT Year: 2013 Tube: Performix HD+ with 73253800 and Tube scan second 186,620 Tube Year: 03/2022
Hitachi Supria (16 slice CT ) Mfg. Year : 2016/8 System Software Version : V2.10 Application Software Version : V2.10 X Ray Time : 367,548.35seconds
Toshiba Aquilion LB 16 Slice CT Year: 2012 Water Cooling Tube Model & Year: MCS-7078/ 07-2019 Tube Slice Seconds: 266093 sec Software Version: V6.0, SP0619E , Base V11.4, SP0004 fully functional, no problems
Philips Ingenuity Core 128 Slice CT Scanner Year: 08/2014 Tube Model & year : MRC-880-05/2014 Software Version: 4.1.10