Ethicon is a well-known brand that produces a variety of medical products, including surgical sutures. Vicryl is one of the types of sutures offered by Ethicon. Vicryl sutures are composed of a synthetic material called polyglactin, which is a copolymer of glycolide and lactide. These sutures are absorbable, meaning they are designed to be broken down by the body over time, eliminating the need for suture removal. Vicryl sutures are commonly used in a wide range of surgical procedures, including general surgery, gynecology, urology, and more. They are known for their flexibility, ease of handling, and the fact that they do not require removal since they are absorbed by the body.
Ethicon Prolene is a brand of surgical suture material, and the notation "2/0" refers to the size or diameter of the suture. The cutting needle indicates the type of needle attached to the suture. A cutting needle is designed with a sharp edge, allowing it to cut through tissues, and it is often used for skin closure and in procedures where a clean, precise incision is needed. So, "Ethicon Prolene 2/0 cutting needle" signifies a Prolene suture with a size of 2/0 and a cutting needle. Here's a breakdown: Ethicon Prolene: Ethicon is a subsidiary of Johnson & Johnson and is known for producing a variety of surgical products, including sutures. Prolene is a type of suture material made of polypropylene. 2/0 (pronounced "two-oh"): This indicates the size or diameter of the suture. In this case, 2/0 is a medium-sized suture commonly used for various surgical procedures. Cutting Needle: A cutting needle is designed for sharp and precise penetration through tissues. It's commonly used in procedures where a clean incision is required, such as in skin closure.
Covidien ABSTACK30 Absorbatack Fixation Device Part # ABSTACK30 Exp 3/19 Covidien ABSTACK30 Absorbatack Fixation Device is an absorbable tack fixation device, for use in laparoscopic hernia repair. The NEW AbsorbaTack (ABSTACK30X) fixation device for laparoscopic hernia repair continues to deploy tacks when the shaft is flexed over 3 cm. Covidien ABSTACK30 Absorbatack Fixation Device Features Designed with patient comfort in mind No metal required for fixation Supports a minimally invasive approach through 5 mm shaft and easy-to-use design Fixation strength Provides strong temporary mesh fixation, with retention strength comparable to the â??gold standardâ?? ProTackâ?¢ fixation device at 1 week and 2 months in an animal model1 Peace of mind Reduces the likelihood of inadvertent needle sticks in the OR, since no sharp piloting needles are required for deployment Potentially fewer visceral attachments than permanent tack fixation1 Violet tack with black-dot visualization feature to optimize visibility In Perfect sealed condition but past expiration date. Not for human use in the US. Expiration dates have mostly to do with sterilization and not the integrity of the product. The manufacturers sterilize the products after they are packaged and it lasts so many years. The only products we caution customers about are ones that are absorbable or drug coated.
Hand function position fixed splint (AJY-S09) It is used for the fixation of stable fractures of the hand and wrist, the fixation of neuromuscular and tendon injuries, and the fixation of functional positions after orthopaedic surgery. Prevent deformity caused by bone and joint disease in thumb-to-finger and palm-to-hand positions shape. 337*170*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Hand rest position fixed splint (AJY-S08) It is used for fixation after orthopedic surgery such as hand and wrist fractures, nerve tendon injuries, scar contractures, etc., to prevent or correct the deformities caused by bone and joint, neuromuscular disease. 360*210*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb-fixed splint (Herringbone) AJY-S02 It is used for thumb metacarpal bone, acute metacarpal arthritis, thumb sprain, rheumatoid arthritis, post-tiger occidental occidental surgery and thumb function fixation after median nerve injury. 200*165*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Elbow Joint Splint (AJY-S12) It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint. 448*260*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Achilles tendon dorsal splint (AJY-S11) It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot. 442*247*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wrist Splint (Tubular Type) AJY-S07 For wrist or distal forearm fractures, functional fixation of wrist arthroplasty, and rest for wrist arthritis and other lesions Position immobilization or lunate dislocation colles fracture fixation. 300*280*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb plate (tubular type) AJY-S03 For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation. 210*145*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Kaon Series Ubiquitous OCT Scanner for Industrial Inspection OCT Testbed with built-in PC for sample analysis. Product Specifications: - Center wavelength: 840 nm - Output power: > 1 mW (high power available upon request) - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 m (in air) - Lateral resolution: < 15 m - A-scan rate: 26,000 per second (typical) - Scan Pattern: Cross, Volume, Raster, Circle (Customization available) - Pixel Resolution: 1024 x 256, 512 x 128 (typical) - Scan Range: 6 mm x 6 mm (changeable by built-in PC) Product Interface & Dimensions: - Data interface: HDMI (monitor not included) - Power Supply: DC Adaptor (included) - Dimension: 240 mm(W) X 100 mm(D) X 260 mm(H) (approx.) - Weight: less than 1 kg
Kaon Series Ubiquitous OCT Scanner for Industrial Inspection OCT Testbed with built-in PC for sample analysis. Product Specifications: - Center wavelength: 840 nm - Output power: > 1 mW (high power available upon request) - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 m (in air) - Lateral resolution: < 15 m - A-scan rate: 26,000 per second (typical) - Scan Pattern: Cross, Volume, Raster, Circle (Customization available) - Pixel Resolution: 1024 x 256, 512 x 128 (typical) - Scan Range: 6 mm x 6 mm (changeable by built-in PC) Product Interface & Dimensions: - Data interface: HDMI (monitor not included) - Power Supply: DC Adaptor (included) - Dimension: 240 mm(W) X 100 mm(D) X 260 mm(H) (approx.) - Weight: less than 1 kg
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time:
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time:
Affordable Kaon Series Ubiquitous OCT Scanner for Ophthalmology This optical coherence tomography (OCT) scanner is compact, slit lamp base mountable, and quite versatile. Product Specifications: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9m (in air) - Lateral resolution: ~20m - Scan range: ~9 mm x 9 mm - Power Supply: USB-A and/or Power Adaptor - A-scan rate: 26,000 per second (typical) - Output power: 750W - Dimension: 200 mm(W), 80 mm(D), 150 mm(H) - Pixel resolution: Line (512, 1024), Volume (512 x 128) - Interface: USB 3.0 to external PC
Handheld Kaon Series Ubiquitous OCT Scanner for Ophthalmology This OCT scanner is optimal for patients in supine position as well as animals Product Specification: - Center wavelength: 840 nm - Imaging depth: 2.6 mm (in air) - Depth resolution: 9 micrometers (in air) - Lateral resolution: ~20 microwatts - Battery Details: Charging time: