1. durableâ andâ strongâ reinforcedâ nylonâ mountâ &â 304â stainlessâ steelâ components. 2. strongâ compositeâ fiberâ glassâ shaft, â underwaterâ depthâ adjustment. 3. aluminumâ head. 4. 6-inchâ telescoping handleâ ass'y. 5. 90â°â twistâ tillerâ adjustmentâ withâ 10â grades. 6. 5â forwardâ speedsâ &â 3â reverseâ speedsâ control. 7. indicatorâ ofâ 10â ledsâ asâ powerâ reader, â batteryâ savingâ systemâ forâ moreâ runningâ time. 8. highâ temperatureâ resistanceâ bakeliteâ switch. 9. ulâ wireâ cablesâ toâ supportâ theâ bigâ current. 10. inputâ 12v(32/36/40/46/50/55/60lbs)â orâ 24v(86lbs). 11. weedlessâ macheteâ propeller:â 2-bladesâ forâ 32/36/40/46lbsâ andâ 3-bladesâ forâ 50/55/60/86lbs. 12. worksâ bothâ inâ freshwaterâ andâ saltwater. 13. oemâ andâ customizationâ available. 14. warranty:â twoâ yearsâ &â 2%â freeâ spareâ partsâ areâ available. 15. ceâ certificate.
1. durableâ andâ strongâ reinforcedâ nylonâ mountâ &â 304â stainlessâ steelâ components. 2. strongâ compositeâ fiberâ glassâ shaft, â underwaterâ depthâ adjustment. 3. aluminumâ head. 4. 6-inchâ telescoping handleâ assâ??y. 5. 90â°â twistâ tillerâ adjustmentâ withâ 10â grades. 6. 5â forwardâ speedsâ &â 3â reverseâ speedsâ control. 7. indicatorâ ofâ 10â ledsâ asâ powerâ reader, â batteryâ savingâ systemâ forâ moreâ runningâ time. 8. highâ temperatureâ resistanceâ bakeliteâ switch. 9. ulâ wireâ cablesâ toâ supportâ theâ bigâ current. 10. inputâ 12v(32/36/40/46/50/55/60lbs)â orâ 24v(86lbs). 11. weedlessâ macheteâ propeller:â 2-bladesâ forâ 32/36/40/46lbsâ andâ 3-bladesâ forâ 50/55/60/86lbs. 12. worksâ bothâ inâ freshwaterâ andâ saltwater. 13. oemâ andâ customizationâ available. 14. warranty:â 2â yearsâ &â 2%â freeâ spareâ partsâ areâ available. 15. ceâ certificate.
SE564 ORP Sensor Heavy duty ORP sensor providing high reliability and precision Heavy duty ORP electrode designed for highly contaminated media and high-pres- sure applications with pressure fluctuations. The state-of-the-art polymer electrolyte of the reference system provides good long- term stability. The 2-hole junction prevents blocking also in waste water containing solid impurities. The platinum electrode is insensitive to oxidizing acids even at elevated temperatures. Facts perfect galvanic isolation thanks to Memosens technology no influence of humidity in the connector digital data transfer integrated sensor diagnostics state-of-the-art polymer electrolyte integrated temperature detector 2-hole junction - no blocking for industrial sewages for processes with large pressure fluctuations suitable for solvent-containing processes Applications Process industry, chemistry, industrial sewage, high-pressure applications Specifications ORP: -1500 mV ~ +1500 mV Temperature: 0 ~ 130 'C Pressure: up to 10 bars Temperature detector NTC 30 kohms Sensor material: platinum Reference system: Ag/AgCl, polymer electrolyte Junction: hole (2x) Length: 120 mm / 225 mm Sensor cap: Memosens ATEX certificate: II 1 G Ex ia IIC T3 / T4 / T6
BENEFITS Small Size with Low Profile (20x20 x3.0mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Low Power Consumption Individually Calibrated (NIST Traceable) ROHS Compliant APPLICATIONS Fixed Industrial Safety Monitoring Portable Industrial Safety Detection Portable Personal Safety Monitor Indoor Air Quality Monitoring Outdoor Air Quality Monitoring Bad Breath/Halitosis Respiration Sensing DESCRIPTION SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost andll size.
The design of a switch mode power transformer will differ depending upon the type of circuit used. There are many variations of switching mode power supplies, but they can be narrowed down to three basic circuit configurations (each also has a mirrored configuration); buck, boost, and fly back. Be aware that the name for the buck circuit varies from industry to industry and from person to person. It may also be referred to as an inverter, d.C. Converter, forward converter, feed forward, and others. There are also unipolar and bipolar (push-pull) versions. Features : * non-corrosive * light weight * long lasting * high performance * long performing life
An additional advance in the case of metal oxide sensor technology is the use of AC rather than DC interrogation of the sensing material.This approach provides complementary atmospheric composition information from the real part and the imaginary part of the sensor impedance and introduces a marked enhancement in terms of sensitivity and selectivity. The SMS is designed to work with up to 8 metal oxide gas sensors. It has circuits to accurately control sensor heater temperature based on digital control loops. The individual sensor heater 'C resistance and temperature coefficients can be set, and there are a number of heater setpoint algorithms that can be selected as parameters.These include temperature ramps, timed temperature schedules and control by an external RS485 interface.Temperature setpoint algorithms can be set in pairs, or slaved to the first pair as required. The SMS unit measures the impedance of the sensing element by applying a controllable synthesised sine wave to a potential divider formed by a top resistor (selectable between 100kR and1MR by an on-board jumper) and the sensor: The sensor resistance is displayed by the PC monitor software, as is a measure of the quadrature (reactive) component. Specification 4 or 8 MMO sensor channels, configurable for a wide range of MMO sensors. digital control of heater temperature using an adaptive algorithm and a number of heater temperature profiles to aid selectivity. measurement of real and imaginary sensing element impedance. usable with a wide range of sensors, to sense alternative gases. a range of interface options including CAN, RS485 and RS232. supplied with a suitable mains to 12V power supply plug. available with PC monitor software, or information to allow users to write their own interface software.
EKO Heat Flow Sensors MF-180 MF-180M MF-190 MF-200 EKO Heat Flow Sensors are suitable for the direct measurement of heat flow inside materials, and the measurement of the radiant flow emitted by bodies such as refrigerators and containers. Principle of thr measurement There are three modes in heat transmission,thermal conduction, radiation and convection. If the heat flow sensor is placed on the surface of the material, it measures the total value of those three modes. If the sensor is placed inside the material, it directly measures the heat transmission caused by thermal conduction.
A single unit, based around a powerful 32-bit floating-point ARM microcontroller, designed to provide a complete analysis of local air quality. The unit deploys four electrochemical sensors, an NDIR CO2 sensor and a laser particle monitor. These combine with a temperature and relative humidity sensor, and GPS is used for accurate location and timestamping.There is also an optional microphone to provide ambient noise information. Data is stored locally and uploaded to a central management site. Specification accurate electrochemical cells (Alphasense A4) monitoring CO, NO, NO2 , and O3 down to ppb levels. Other gases can be sensed if required (eg SO2 ). digital NDIR CO2 sensor (Atmospheric Sensors/Alphasense or SenseAir). laser optical particle counter (Alphasense) to provide PM1, PM2.5 and PM10 readings. PID sensor for volatile organic compounds (VOCs) (Alphasense). temperature and relative humidity sensor (Atmospheric Sensors). high-sensitivity GPS module capable of accurate location and time measurement even inside buildings. microphone to characterise ambient noise, based on a hardware RMS level detector. data can be sampled at high rates, which are normally averaged over 20 seconds, with data transmission every 15 minutes. This can be configured to suit each application. communication link to remote database via GPRS. This includes the ability to 'store and forward' data in times when the network is down or temporarily overloaded. The unit requires a data-capable SIM card service, which can be provided either by Atmospheric Sensors or by other providers by discussion. local storage on 16GB SDCard of extended results from test for later recovery and to act as a backup of results sent over the GPRS link. mains power supply, with waterproof connector. externally visible LED to indicate unit status. the unit may be used either indoors, or outdoors if protected by a Stevenson Screen, or similar enclosure. Wall mount brackets are supplied with each unit, permitting easy installation.
Based on Infrared absorbing principle, not only it is well selective to the target gas, but also detecting accurately and stable to gas concentration. The module is compact structure, free maintenance, application is various industry situation.
CDM4160 is a new unit which uses TGS4160, Figaro's durable solid electrolyte CO2 sensor. Due to Figaro's proprietary idea for signal processing with a microcomputer,no maintenance is required for this module. By application of DC voltage to the module, an analog output voltage proportional to CO2 concentration can be obtained. The module can generate a control signal based on a user-selectable threshold concentration. The features mentioned above make this module ideal for air quality control applications in homes, offices and factories as well as in the field of agriculture. Features: * High selectivity to CO2 * Long life * Maintenance free * Pre-calibrated * Low cost * Wide detection range * Excellent durability Applications: * Indoor air quality control in offices, homes, and factories * CO2 monitors * Agricultural applications
Taibri thermal actuators heated by positive temperature coefficient (PTC) heater. These are often used in room thermostat or radio control for floor heating. Models with 230V (with built-in overvoltage protection 2.5kv) and 24V operating voltages PTC heater. The positioning force within the close range is adapted to thermostatic valve bodies with soft valve discs.
The complete fluid control function integrated into a single unit. We can supplied actuators without housing. Developed to comply with the most demanding worldwide standards.
Compact size and unibody type Excellent EMI/EMC and noise properties Embedded ASIC for high accuracy Wide range(-40 to 100°C) DIN and cable type Perfect compatibility with dotech's air compressor controllers
Frequency range (mhz) vhf174~230/uhf470~860 Bandwidth (mhz) v56/u390 Input impendence (o) 50 V.S.W.R =1.5 Gain (dbi) 3 Max input power (w) 50 Mechanical specifications Antenna length (mm) 120 Cable (mm) 3000 Connect type sma male or as customers’ Requirement Mounting magnetic base Radome color black Weight (g) 180
Center frequency (mhz) 1575.42mhz Bandwidth (mhz) 6mhz Input impendence (o) 50 V.S.W.R =1.5 Consumption electric
Frequency range (mhz) 850/900/1800/1900/2170 Input impendence (o) 50 V.S.W.R =1.8 Gain (dbi) 9db Polarization type vertical Radiation direction omnidirectional Max input power (w) 50 Mechanical specifications Antenna length (mm) 357±10 Base diameter(mm) 50 Cable (mm) 3000 or customized Connect type sma or customized Mounting ?? magnetic base Radome color ?? black Cableers rg58 or customized Suction(kg) 3.0
Frequency range (mhz) 600-2700 Bandwidth (mhz) 1000 Input impendence (o) 50 V.S.W.R =2.0 Gain (dbi) 35db Polarization type vertical Power capacity (w) 50 Antenna length (mm) 22*19*2.1cm Radiator cuprum Connect type ts9 or crc9 or sma Working temp(?) - - 40~60 Radome color white Weight (g) 290 Pls contact me for latest catalog and best price, thank you!
1.General description The luminox family (lox) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo2) levels using the principle of fluorescence quenching by oxygen. By default luminox measures ppo2 (mbar) and temperature (°c). An optional pressure sensor enables luminox to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (o2%). The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle. Luminox is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, luminox is very stable and robust, does not contain lead or any other Hazardous materials and has negligible cross sensitivity to other gases. 2.Cleaning The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media. Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required. 3.Benefits -low power -can also measure o2% & barometric pressure (lox-02) -suitable for battery power use -long life - high accuracy - small & compact - low cost -maintenance free contains no hazardous materials -connects directly to microcontroller - without any additional circuitry. - factory calibrated 4.Applications -oxygen detection -portable equipment - breathing apparatus - inerting - medical -lab equipment - agriculture -incubation -fire prevention - flue gas in condensing boilers
Oxygen sensor o2 gas sensor for portable gas detector Model number: o2-a2 Performance Output µa @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current µa in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40°c < 0.7 Co2 sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range °c -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20°c (store in sealed pot, open circuit) 6 Load resistor o (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16
Factory calibrated methane sensor module for methane sensor tgs2611 Model number: ngm2611 Features: * factory calibrated * temperature compensation circuit * low power consumption sensor tgs2611 * compact size * meets rohs regulations Applications: * residential natural gas alarm Description The ngm2611 is a pre-calibrated module for natural gas alarms which is precisely Calibrated in figaro's humidity and temperature controlled facility. The most important process in manufacturing reliable resdential gas alarms is Adjusting the alarm point. Calibration is a complicated and time consuming Process which also requires a substantial investment in calibration equipment. By Eliminating the costly calibration process, this module enables users to easily and Simply manufacture residential natural gas alarms. Figaro has taken the complexity Out of designing a gas detector circuit by providing users with a temperature Compensation circuit which combines a built-in thermistor and individually adjusted Load resistor together with figaro’s low power methane gas sensor. A connector allows easy replacement of the module for the purpose of periodic Sensor renewal. This input/output connector enables easy installation of the Module into the gas detectors’ mother board. This same mother board can be Used for both methane and lpg gas detectors by simply changing the module. This module is designed to meet the performance requirements of en50194, and ul1484. Please refer to “technical information for tgs2611” for sensor sensitivity characteristics. Refer to “application notes for tgs2611” for further information regarding circuit design.