• conformity to international standards – iec, ul, csa, ce • 9-150 amps, 3 and 4 pole versions, ac/dc coils • high temperature limits • different levels of power and control contacts • inbuilt 1 no + 1 nc auxiliary contacts • high electrical life • fuse-less type 2 coordination charts available
• ever higher performance for your motors assured by: - the factory settings, which provide a high quality drive from the very first time the power Is turned on - the integration of standard (u/f), performance (sensorless flux vector control, or svc) And pump/fan (quadratic profile kn²) control profiles - high dynamic performance on acceleration as well as on braking - excellent speed regulation on machine load surges • reduced noise and maintenance: - no fan on models up to 0.75 kw at 240 v - cassette type fan, operates automatically on detection of specific temperature setting • designed for easy fitting and wiring of the drive: - a single tool - power terminals not tightened, ready for wiring - easy access angles - numerous, easy to identify markings • fast detection and protection against the motor current peaks associated with certain Applications (motor switching, catching on the fly, etc.) • perfect integration of single-phase 240 v model into the electrical network thanks to Its built-in emc filter
Customized Dimention and Shapes of Nylon Filter Mesh SHARE nylon mesh discs with opening sizes ranging from 16 microns to 1500 microns. While Share manufacture filter mesh disc, we also provide this mesh in other customized shapes by laser cutting, and the mesh insert injection molded filters. We strive to bring application-specific functionality to various industries by customizing our products. Please contact us if you have further questions about the customization options of nylon mesh.
Gas Insulated Switch Gears, Hv/mv Vacuum Circuit Beaker, Swithc Gear Components, Etc..
Explosion proof servomotor.
Electric motors, electric gear box.
Appliances, electrical, and electronics manufacturers.
Silver rivet contact, silver tungsten contacts, electrical contacts, silver wires, silver alloy strips, contact tips, contact points.Design
Microwave ferrite materials, ferrites & magnetic materials include narrow linewidth, aluminum & aluminum gadolinium substituted garnets, gadolinum substituted garnets, cobalt & holmium doped garnets, magnesium spinels, nickel spinels, lithium spinels.Manufacturer
Electrical switchgear refers to a centralized collection of circuit breakers, fuses, and switches (circuit protection devices) that function to protect, control, and isolate electrical equipment. The circuit protection devices are mounted in metal structures.
Condition: New Support: Boschh, Densoo and Delphhi Model: CR1000 Type: Rail Injector Tester Features: Modulated driving signal to ensure the safety of the solenoids of the injectors Injector driving signal Adjustable frequency and pulse width Short circuit protection for solenoid driving signals Rich accessories, Fit for Boschh, Densoo and Delphhi injectors
One important element of good power system design is the proper selection of the distribution equipment. The choice of using either switchgear or switchboards must be based on many different criteria and the design of the power system requires thought be given to each one. Tungwell's sister company CPEPEC is a vertically integrated manufacturer and fabricator of engineered material solutions for switchgear applications. We manufacture custom material solutions for the following types of equipment: Medium & High Voltage Circuit Breakers Pad Mounted (Live & Dead Front) Medium Voltage Switchgear Metal Clad Medium Voltage Switchgear Automatic Transfer Switches Motor Control Switchgear Metering Equipment Low Voltage Switchgear Panelboards Switchboards We supply a complete line of insulating components for a broad range of switchgear designs. These components and spare parts can be provided individually or in complete kits for a particular type of switchgear.
1xN mechanical optical switch is a kind of light path control equipment,Can realize multi-channel fiber optic light path switching,In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system. Features Low Insertion Loss Wide Wavelength Range TTL level control, easy to control Imported components, better stability Drive circuit breakdown self check function Modular design, convenient for secondary development
Impact specimen gap hydraulic broaching machine is the only instrument gap for processing the qualified sample except the optical curve grinding machine. Because of processing theory once, the identity of processing the gap is very nice. This broaching machine adopts w18cr4v manufacturing, high hardness, wear resistance, and every tool can process the sample as many as 20, 000.
Electromagnetic Flowmeter explosion-proof electromagnetic flowmeter intelligent electromagnetic flowmeter Product code: 145538-152 Update time: 2015.08.25 Views: 1304 Processing custom origin: In kaifeng Type: Type flow meter SKLD series Measuring range: 2000 (m3 / h) Level of accuracy: 0.5 Nominal diameter: DN3-3000 (mm) Working pressure: 0.6 ~ 4 (MPa) Working temperature: - 10 ~ 150 Product Overview SKLD type electromagnetic flowmeter is the intelligent electromagnetic with research and development, which adopts domestic and foreign adva nced technology. Electromagnetic transducer with high-speed central processing unit (CPU) and the features of rapid computing speed and high precision, reliable performance measurement are in both Chinese and English menu.Electromagnetic Flowmeter is divided into one type of electromagnetic flowmeter and split electromagnetic flowmeter,Insert electromagnetic flowmeter. Electromagnetic flowmeter can be divided according to the use of function:liquid flow meter,water flow meter,sewage flow meter,Intelligent electromagnetic flowmeter,explosion-proof flow meter,irrigation flow meter,mud flow meter Sensor uses non-uniform magnetic field technology and special magnetic circuit structure. Magnetic field is stable and reliable, and the circuit structure reduces the volume, The sensor can reflect the traffic change timely and effectively, and have a stable value of measuring water, sewage, slurry, pulp, acid, alkali, salt slurry liquid and food, etc. There are lots of wide applications in the petroleum chemical industry, metallurgy, coal, water conservancy project of water supply and drainage, sewage treatment etc. The electromagnetic flowmeter has two types: the compact and the sensor for remote transmitter. Product Features In-line unimpeded flow components, measurement of almost no loss of pressure, low straight pipe requirements Measurement results and the velocity distribution, fluid pressure, temperature, density, viscosity and other physical parameters Blank-pipe measurement function without additional electrode, continuous measurement, the fixed value alarm Velocity measuring range: 0.1-15 m/s, velocity resolution: 0.5 mm/SEC Low frequency square wave excitation and excitation frequency: 1/16, 1/20, 1/25 power frequency power frequency power frequency High frequency square wave excitation and excitation frequency: 1/2 power frequency (applicable to size measurement) (optional) Explosion-proof instrument can be used for the corresponding explosion-proof occasions
Turbine flowmeter compressed air flowmeter gas flowmeter Product name: turbine flowmeter Product code: 164912-752 Update time: 2015.08.25 Views: 346 Processing custom origin: in kaifeng Type: type flow meter LWG series Type: impeller type flowmeter Measuring range: 0.4-20000 (m3 / h) Level of accuracy: + / - 1.5% Nominal size: 10-500 (mm) Working pressure: 2.5, 6.3, 16 Working temperature: - 20 ~ 55 Summary: Turbine flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. LWG type turbine flow sensor and receiving electrical signals of the display instrument of Turbine flowmeter, which is used to measure low and medium viscosity closed pipes Degree of fluid (liquid or gas), the total volume flow and in petroleum, chemical industry, metallurgy, aviation and scientific research departments for a wide range of applications. Sensor is composed of turbine sensor components and amplifier, the structure of the two together for one-piece: to measure the structure of the positive and negative flow For two-way type; With inserted rod can be installed in the large diameter pipe flow body flow structure for a plug-in. Based on the principle of moment balance sensor work. When the fluid flows through the sensor, promote the impeller rotation, when the flow rate must be dynamic torque Maintain and drag torque balance, the impeller speed. Evenly distributed on the permeability of the impeller blade with the impeller rotation, to periodically change detection The reluctance of the magnetic field sensor (coil), electrical pulse signal detector, after the amplifier amplification output. The output electric pulse frequency and impeller speed Is proportional to the impeller speed is proportional to the flow in, so the output electric pulse frequency is proportional to the flow sensor flow, 4-20 ma signal is converted is proportional to the flow. Features: 1) impurity resistance is strong, tangential impeller rotating at can release floating debris in the fluid at any time, when the winding on tangential impeller blades. 2) resistance to electromagnetic interference and strong vibration resistance. 3) the structure and principle of the sensor and display instrument is very simple, user especially easy to master its use and maintenance technology. 4) after replacement of impeller and bearing, meter coefficient is constant. 5) wide flow range, lower limit velocity is low. 6) complete sets of flow meter for the measurement of the fluid volume error is small. 7) almost no pressure loss, save power consumption. 8) sensor can be installed in open air, the sensor can be submerged in the water use for a long time. 9) have a globe valve sensor, install and remove all don't need to stop. 10) horizontal, vertical, inclined pipe can be used. 11) complete sets of flowmeter the purchase, installation, and low cost.
Ring chamber orifice meter ring chamber orifice meter manufacturer Product name: Ring chamber orifice meter Product code: 151116-813 Update time: 2015.08.25 Views: 860 Processing custom origin: in kaifeng Type: type throttling device LWG Type: volumetric flowmeter Measuring range: 0-100 (m3 / h) Level of accuracy: + / - 1.0% Nominal size: (DN50- DN2600 (mm) Job stress: 40 or less (MPa) Working temperature: 70 ) Summary: throttling device, also known as differential pressure flowmeter, Orifice flowmeter contains (integrated orifice flow meter, standard orifice, annular orifice flow meter, integrated annular orifice flow meter) Ring chamber orifice meter can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter. LWG type series annular orifice meter is SIKE measurement and control technology co., LTD., henan overview on the research and development on the basis of the standard orifice throttling flow sensor, because it USES annular single structure, make measurements in all kinds of dirt medium through the orifice plate with a circular seam between pipe can easily pass. So the circular orifice flowmeter is widely applied in the dirt medium flow measurement. Circular orifice itself comes with a measuring tube. In central measuring tube fixed a concentric circular plate - flow plate, the plate of the bearing steel in the mouth (10) and take pressure staggered, so bearing steel downstream of the flow of the fluid resistance is negligible, and the upstream flow plate without any block, can make the upstream velocity distribution axisymmetric completely, is advantageous to the geometric similarity and dynamic similarity, improve the accuracy of measurement. Circular orifice meter is suitable for various fluid (gas, steam, liquid medium, such as: saturated steam and superheated steam, compressed air, all kinds of exhaust gas, burning furnace, cooling water, heavy oil, residual oil, fuel oil, condensate, all kinds of corrosive chemical solution, etc. Features: 1, not only can measure the general fluid flow, and can also be applied to contain various impurities such as dust, suspension, precipitation, etc.) of the fluid, such as a variety of hot gas, flue gas, natural gas, cooling circulating water, etc. 2, measuring saturated steam superheat steam can avoid stop steam condensate accumulation formation, when steam again to send, can quickly into the accurate measurement. 3, instrument ontology has a straight measuring tube, on-site installation, the installation error (such as eccentric, sealing gasket into pipe) has no effect on meter almost.
1. The test angle is based on national standards gb4706.1-2005 (iec60335-1: 2004) chapter 11, " fever " in the design and manufacture of test requirements. 2.The test angle is mainly used for a variety of electrical, temperature testing provides electrical products meet the standard requirements of environmental conditions temperature test. The actual test sample can be customized with different distribution specifications, test angle number and dimensions of the measurement points.
The spray tester ipx 3/4 is a hand-held test device to verify protection against spraying and splashing water. The water pressure can be adjusted using the flow control knob on the device to give the required flow rate. The pressure can be seen on the gauge which is convenient positioned by the spray tester ipx 3/4. The spray pattern of the nozzle is made to the specifications of ie60529. The removable shield feature make it easy to test without the interference of the shield.
It is used to evaluate the resistance tracking performance of solid insulating material surface under the combined influence of electric field and humid or contaminate medium. Sum up,it is used to measure the compare tracking index (CTI) and electrical resistance index (PTI).