GBCDG31FF013SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF013SB(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.2 - 0.8 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 902 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-101-1
ALSTOM GBCDG31FF013SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF013SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.2 - 0.8 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 902 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-103-1
ALSTOM GBCDG31FF014SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF014SBCH RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.1 - 0.4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 901 Outline Diagram MFJ013 Wiring Diagram MFDZ801-101-1
ALSTOM GBCDG31FF014SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31FF014SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.1 - 0.4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 901 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-103-1
GBCDG31FF015SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical specification Relay model No CDG31FF015SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Current setting - E/F 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 1.3 Secs C.T.Secondary 1 amps Frequency 50 Hz Flag Yes Mounting Flush Name Plate RFG9125 902 Outline drawing MFJ 013 Wiring diagram MFDZ 801.130-1
GBCDG31FF021SBCH IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ. Technical specification Relay model No CDG31FF021SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Current setting - E/F 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 3 Secs C.T.Secondary 5 amps Frequency 150 Hz Flag Yes Mounting Flush Note to test:Relay to test 150 Hz. refer test inst. Name Plate RFG9126 903 Outline drawing MFJ 013 Wiring diagram MFDZ 801.101-1
Alstom Gbcdg31ff8101lch 3idmt,2 O/c & 1 E/f ,3va 3 Secs Dmt 50hz Technical Specification Model No. Cdg31ff8101lch Case Size : 3d Ver. Application : 2 O/c & 1 E/f Ct Secondary : 5 Amps Current Setting O/c : 2.5 to 10 Amps Current Setting E/f : 1 to 4 Amps Contacts : 2m 2b H/r. Output Contacts : 2m 2b H/r. Taps : Std. Burden / Operating Time : 3 Va 3 Secs. Frequency : 50 Hz. Name Plate : Rfg9126 904 O/l & Arrangement : Mfj 013 Wiring Diagram : Mfdz 801.95 - 1
Alstom Gbcdg31ff8111lch 3idmt,2o/c & 1e/f,3va 1.3secs, Dmt 50hz Technical Specification Relay Model No Cdg31ff8111lch Type Cdg31 Application 2 O/c + 1 E/f Burden / D.m.t. 3va / 1.3 Sec. C.t. Secondary 5 Amp C.t. Case Size 3d Vert. Contacts (S/r or H/r) 2 N/o 2 N/c H/r E/f Setting 1 - 4 Amps. Flag Yes Frequency 50 Hz Mounting Flush O/c Setting 2.5 - 10 Amps. Name Plate Rfg9125-904 Outline Drawing Mfj013 Wiring Diagram Mfdz801.95-1
Alstom Gbcdg61eg001zmch Obs.replaced by Gbcdg61eg101zmch Obs Model .replaced by Model List Gbcdg61eg101zmch
ALSTOM GBCDG61EG003SXCH IDMT THREE O/C RELAY WITH HIGH-SET Technical Specification Relay model no CDG61EG003SXCH Relay type CDG 61 Case size 3D HOR.30T Application O/C Current setting - O/C 2.5 to 10 amps Contacts 3Meter S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps Std Frequency 50 Hz Burden 3 VA Operating time 3 secs Flag Yes High set - O/C Setting 20 to 80 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 774 Outline drawing MFJ 014 Wiring Diagram MADZ 821.27-1
ALSTOM GBCDG61EG006SXCH IDMT THREE O/C RELAY WITH HIGH-SET Technical specification Relay model no CDG61EG006SXCH Relay type CDG 61 Case size 3D HOR.30T Application O/C Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Taps Std Frequency 50 Hz Burden 3 VA Operating time 3 secs Flag Yes High set - O/C Setting 4 to 16 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 771 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG011SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no CDG61EG011SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps / Frequency STD / 50 Hz Burden 3 VA Operating time 3 secs Flag Yes Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG018SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG018SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Tap Std Burden / D.M.T 3 VA / 3 Secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set/High set contact CAG 13 / 2 N/O S/R Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
We Are Hoang Ha Co Ltd In Viet Nam We Are Making By Hand Art Floor Lamp We Going To Forest To Chose Some Special , Nice Shape Of Tree , ..made Unique Lamp . You Can Chose Lamp Shade They Look Very Stranger And It Is Unique You Can Not Seen Before Put It In Your Home , So It Standing Out Among Your Model Furniture Please Be Artist Size : H 160 Cm
Prominent & Leading Manufacturer from Hyderabad, we offer 500ml saaz excel toilet cleaner and laundry liquid detergent Approx. Rs 89 / PieceGet Latest Price Product Details: Country of Origin : Made in India Packaging Type : HDPE Bottle Packaging Size 500 ml Brand Saaz Excel Form Liquid Shelf Life 24 months Usage/Application For Toilet Cleaning Matching up with the requirements of our clients, we are involved in offering 500ml Saaz Excel Toilet Cleaner.
Abbott BMW Guide Wire with hi-torque balance middleweight universal guide wire is a front-line guide wire offering a unique balance of support and flexibility, with enhancements in the areas of device compatibility, distal access, deliverability in tortuous anatomy and tip durability. INDICATIONS FOR USE This HI-TORQUE Guide Wire is intended to facilitate the placement of balloon dilatation catheters during Percutaneous Transluminal Coronary Angioplasty (PTCA) and Percutaneous Transluminal Angioplasty (PTA). This guide wire may also be used with compatible stent devices during therapeutic procedures. CONTRAINDICATIONS Not intended for use in the cerebral vasculature or with atherectomy devices. WARNINGS This device is designed and intended for ONE-TIME USE ONLY. Do not resterilize and / or reuse. Carefully observe the instructions under Do Not and Do below. Failure to do so may result in vessel trauma, guide wire damage, guide wire tip separation, or stent damage. If resistance is observed at any time, determine the cause under fluoroscopy and take remedial action as needed. Use the most suitable guide wire for the lesion being treated.
Guide wires with a high manoeuvrability in the chronic occluded lesion, and a tip designed to improve penetrability into the lesion while remaining flexible. Features 0.014" Guide wire Tapered tip options, 0.010" (1.7gf wire), 0.011" (3.5gf wire) and 0.012" (4.5gf wire) 1.7gf, 3.5gf and 4.5gf Tip load options 1:1 Torque 40cm Hydrophilc coating 15cm Spring coil length 15cm Radiopaque segment Available in 190cm and 300cm lengths
The Axial turbine is for low head power plants. Water flows axially into and out of the turbine. Axial flow turbines fall into two categories, fixed blade runner and variable pitch runner, also known as a Kaplan turbine. Fixed blade turbines are very well suited to low head power plants with limited variation in head and load. Its main advantage is its simple design. When operated at fixed speed, maximum efficiency is achieved at the design head and water flow. Kaplan turbines are used for medium to large power stations where there are large variations in the head, water flow and load. Its main advantage is its ability to adapt to variable conditions with a high efficiency. The variable pitch runner is mechanically more complex than a fixed pitch runner. Axial flow turbines can be supplied for a head of 2m to 70 m. The runner diameter is available from 0.6 m to 5 m. Power capacity is from 55 kW to 50 MW.
The tubular turbine is an axial flow turbine, in a straight or S-shaped configuration. A Tubular Turbine can be supplied for a head of 2 m to 30 m. The runner diameter is available from 0.8 m to 5.6 m. Power capacity is from 250 kW to 15 MW. This turbine has high efficiency and lower constructon cost.