Impact specimen gap hydraulic broaching machine is the only instrument gap for processing the qualified sample except the optical curve grinding machine. Because of processing theory once, the identity of processing the gap is very nice. This broaching machine adopts w18cr4v manufacturing, high hardness, wear resistance, and every tool can process the sample as many as 20, 000.
Electromagnetic Flowmeter explosion-proof electromagnetic flowmeter intelligent electromagnetic flowmeter Product code: 145538-152 Update time: 2015.08.25 Views: 1304 Processing custom origin: In kaifeng Type: Type flow meter SKLD series Measuring range: 2000 (m3 / h) Level of accuracy: 0.5 Nominal diameter: DN3-3000 (mm) Working pressure: 0.6 ~ 4 (MPa) Working temperature: - 10 ~ 150 Product Overview SKLD type electromagnetic flowmeter is the intelligent electromagnetic with research and development, which adopts domestic and foreign adva nced technology. Electromagnetic transducer with high-speed central processing unit (CPU) and the features of rapid computing speed and high precision, reliable performance measurement are in both Chinese and English menu.Electromagnetic Flowmeter is divided into one type of electromagnetic flowmeter and split electromagnetic flowmeter,Insert electromagnetic flowmeter. Electromagnetic flowmeter can be divided according to the use of function:liquid flow meter,water flow meter,sewage flow meter,Intelligent electromagnetic flowmeter,explosion-proof flow meter,irrigation flow meter,mud flow meter Sensor uses non-uniform magnetic field technology and special magnetic circuit structure. Magnetic field is stable and reliable, and the circuit structure reduces the volume, The sensor can reflect the traffic change timely and effectively, and have a stable value of measuring water, sewage, slurry, pulp, acid, alkali, salt slurry liquid and food, etc. There are lots of wide applications in the petroleum chemical industry, metallurgy, coal, water conservancy project of water supply and drainage, sewage treatment etc. The electromagnetic flowmeter has two types: the compact and the sensor for remote transmitter. Product Features In-line unimpeded flow components, measurement of almost no loss of pressure, low straight pipe requirements Measurement results and the velocity distribution, fluid pressure, temperature, density, viscosity and other physical parameters Blank-pipe measurement function without additional electrode, continuous measurement, the fixed value alarm Velocity measuring range: 0.1-15 m/s, velocity resolution: 0.5 mm/SEC Low frequency square wave excitation and excitation frequency: 1/16, 1/20, 1/25 power frequency power frequency power frequency High frequency square wave excitation and excitation frequency: 1/2 power frequency (applicable to size measurement) (optional) Explosion-proof instrument can be used for the corresponding explosion-proof occasions
Turbine flowmeter compressed air flowmeter gas flowmeter Product name: turbine flowmeter Product code: 164912-752 Update time: 2015.08.25 Views: 346 Processing custom origin: in kaifeng Type: type flow meter LWG series Type: impeller type flowmeter Measuring range: 0.4-20000 (m3 / h) Level of accuracy: + / - 1.5% Nominal size: 10-500 (mm) Working pressure: 2.5, 6.3, 16 Working temperature: - 20 ~ 55 Summary: Turbine flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. LWG type turbine flow sensor and receiving electrical signals of the display instrument of Turbine flowmeter, which is used to measure low and medium viscosity closed pipes Degree of fluid (liquid or gas), the total volume flow and in petroleum, chemical industry, metallurgy, aviation and scientific research departments for a wide range of applications. Sensor is composed of turbine sensor components and amplifier, the structure of the two together for one-piece: to measure the structure of the positive and negative flow For two-way type; With inserted rod can be installed in the large diameter pipe flow body flow structure for a plug-in. Based on the principle of moment balance sensor work. When the fluid flows through the sensor, promote the impeller rotation, when the flow rate must be dynamic torque Maintain and drag torque balance, the impeller speed. Evenly distributed on the permeability of the impeller blade with the impeller rotation, to periodically change detection The reluctance of the magnetic field sensor (coil), electrical pulse signal detector, after the amplifier amplification output. The output electric pulse frequency and impeller speed Is proportional to the impeller speed is proportional to the flow in, so the output electric pulse frequency is proportional to the flow sensor flow, 4-20 ma signal is converted is proportional to the flow. Features: 1) impurity resistance is strong, tangential impeller rotating at can release floating debris in the fluid at any time, when the winding on tangential impeller blades. 2) resistance to electromagnetic interference and strong vibration resistance. 3) the structure and principle of the sensor and display instrument is very simple, user especially easy to master its use and maintenance technology. 4) after replacement of impeller and bearing, meter coefficient is constant. 5) wide flow range, lower limit velocity is low. 6) complete sets of flow meter for the measurement of the fluid volume error is small. 7) almost no pressure loss, save power consumption. 8) sensor can be installed in open air, the sensor can be submerged in the water use for a long time. 9) have a globe valve sensor, install and remove all don't need to stop. 10) horizontal, vertical, inclined pipe can be used. 11) complete sets of flowmeter the purchase, installation, and low cost.
Ring chamber orifice meter ring chamber orifice meter manufacturer Product name: Ring chamber orifice meter Product code: 151116-813 Update time: 2015.08.25 Views: 860 Processing custom origin: in kaifeng Type: type throttling device LWG Type: volumetric flowmeter Measuring range: 0-100 (m3 / h) Level of accuracy: + / - 1.0% Nominal size: (DN50- DN2600 (mm) Job stress: 40 or less (MPa) Working temperature: 70 ) Summary: throttling device, also known as differential pressure flowmeter, Orifice flowmeter contains (integrated orifice flow meter, standard orifice, annular orifice flow meter, integrated annular orifice flow meter) Ring chamber orifice meter can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter. LWG type series annular orifice meter is SIKE measurement and control technology co., LTD., henan overview on the research and development on the basis of the standard orifice throttling flow sensor, because it USES annular single structure, make measurements in all kinds of dirt medium through the orifice plate with a circular seam between pipe can easily pass. So the circular orifice flowmeter is widely applied in the dirt medium flow measurement. Circular orifice itself comes with a measuring tube. In central measuring tube fixed a concentric circular plate - flow plate, the plate of the bearing steel in the mouth (10) and take pressure staggered, so bearing steel downstream of the flow of the fluid resistance is negligible, and the upstream flow plate without any block, can make the upstream velocity distribution axisymmetric completely, is advantageous to the geometric similarity and dynamic similarity, improve the accuracy of measurement. Circular orifice meter is suitable for various fluid (gas, steam, liquid medium, such as: saturated steam and superheated steam, compressed air, all kinds of exhaust gas, burning furnace, cooling water, heavy oil, residual oil, fuel oil, condensate, all kinds of corrosive chemical solution, etc. Features: 1, not only can measure the general fluid flow, and can also be applied to contain various impurities such as dust, suspension, precipitation, etc.) of the fluid, such as a variety of hot gas, flue gas, natural gas, cooling circulating water, etc. 2, measuring saturated steam superheat steam can avoid stop steam condensate accumulation formation, when steam again to send, can quickly into the accurate measurement. 3, instrument ontology has a straight measuring tube, on-site installation, the installation error (such as eccentric, sealing gasket into pipe) has no effect on meter almost.
1. The test angle is based on national standards gb4706.1-2005 (iec60335-1: 2004) chapter 11, " fever " in the design and manufacture of test requirements. 2.The test angle is mainly used for a variety of electrical, temperature testing provides electrical products meet the standard requirements of environmental conditions temperature test. The actual test sample can be customized with different distribution specifications, test angle number and dimensions of the measurement points.
The spray tester ipx 3/4 is a hand-held test device to verify protection against spraying and splashing water. The water pressure can be adjusted using the flow control knob on the device to give the required flow rate. The pressure can be seen on the gauge which is convenient positioned by the spray tester ipx 3/4. The spray pattern of the nozzle is made to the specifications of ie60529. The removable shield feature make it easy to test without the interference of the shield.
It is used to evaluate the resistance tracking performance of solid insulating material surface under the combined influence of electric field and humid or contaminate medium. Sum up,it is used to measure the compare tracking index (CTI) and electrical resistance index (PTI).
Features: 1. Material: Alloy Steel, Carbon Steel, Stainless Steel, , Cast Iron, Aluminum, Copper, Brass and so on 2. Heat Treatment: Hardening and Tempering, High Frequency Quenching, Carburizing Quenching and so on. 3. Surface Treatment: Galvanizing/Zinc Plating, chrome plated, Black oxide Treatment, Spray Paint, Mirror Finish, Sand-blasting and so on according to ROHS demand. 4. Inspection: All items are checked and tested thoroughly during every working procedure and after the product is finally manufactured to ensure that the best quality product enter into the market. 5. Durable, bad condition Resistance Our sprocket models for your reference: 1)Short/single pitch sprocket: *Chain matched:35 (06C) Teeth:from 9-120 *Chain matched:40 (08A) Teeth:from 9-120 *Chain matched:50(10A) Teeth:from 9-120 *Chain matched:60 (12A) Teeth:from 9-120 *Chain matched:80 (16A) Teeth:from 9-120 *Chain matched:100 (20A) Teeth:from 9-120 *Chain matched:120 (24A) Teeth:from 9-120 *Chain matched:140(28A) Teeth:from 9-120 *Chain matched:160 (32A) Teeth:from 9-120 *Chain matched:180 (36A) Teeth:from 9-120 *Chain matched:200 (40A) Teeth:from 9-120 2)Double pitch sprocket: *P=25.4mm Teeth:from 7-100 *P=31.8mm Teeth:from 7-100 *P=38.1mm Teeth:from 7-100 *P=50.8mm Teeth:from 7-100 *P=63.5mm Teeth:from 7-100 Packing: Little quantity (Samples ) Carton More quantity: Wooden case Delivery time: standard size  within 10 days.                custom-made size within 15 days. ServiceOEM/ODM
Product details Product Specification Measures from 0-9990ppm Accuracy:+-2%, Battery: 2x1.5V(Button Cell) Size:155x31x23mm(6.1X1.2x0.9in) Use the TDS Meter to: Check the performance of your water filter Check for the hardness (1 grain=17ppm) Make sure you always drink pure water. Features Hold function saves the measurements for convenient reading and recording. Auto-off function:turns off meter after 10 minutes of non-use to conserve batteries. Dual Range: Measures from 0-999ppm,with a resolution of 1 ppm. From 1000 to 9990ppm,the resolution is 10ppm, indicated by drinking x 10 symbol,Factory calibrated. Advantages: Taking Temperature Measurement 1.Once the meter is on,the temperature function can be used at any time, in or out of liquid. 2.Press the TEMP button.The display will switch to temperature(in Celsius only). 3.To return to TDS mode,press the TEMP button. Precaution and notes Do not drop the entire TDS meter in water or dip beyond the maximum immersion level.This unit is not covered under the warranty if water enters the unit. 2. Do not store the TDS meter under high temperature or direct sunlight.This will shorten the life-span of the product and potentially avoid the warranty. 3. The TDS-3 meter is calibrated at 642ppm. It is recommended that the calibration level should be the similar to the sample to be tested.If you are testing higher ppm(member,water quality association). Calibration Your meter has been factory calibrated well. warranty 1.Three year warranty: The product is warranted to the purchaser against material and workmanship for three(3) years from date of purchase. What is covered: Parts and labor , or replacement at the companyâ??s option. Transportation charges to the purchaser. What is not covered: Transportation charges to the company. Damages from the abuse or improper maintenance (see operating instructions and precautions). Any other consequential damages, incidental damages ,or incidental expenses,including damages to the property.Some states do not allow exclusive or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. FAQ Question 1: What is the MOQ of this item ? Answer: The item MOQ is 5000pcs. Question 2: How to pack this item? Answer: Box packing is our usual practice, you can also send us your packing design, and we can packing as your requirement. Question 3: How to make payment? Answer: You can make payment by T/T,Paypal.Western Union and of course cash face to face at our factory. Question 4: What is the lead time? Answer: Our lead time is within 10 days after receive your payment based on MOQ:5000PCS. Question 5: Can you accept OEM & ODM? Answer: Yes, we can accept OEM &ODM -
(TL-101) Digital manometer measures gauge/differential pressure from -55H2O to +55H2O(2 psi) It features 11 selectable units of measure: in H2O, pis, bar,mbar,Kpa,inHg,mmHg,ozin2,ftH2O,kgcm, additional features include data hold and auto power off disabled,careful use of this meter will provide years of reliable service. Features: 1.Max / minimum / average, and with a relative time 2.Large LCD backlit dual display 3.Zeroing, offset, and data compensation 4.Low battery display and automatic shutdown 5.Data Hold and Error code 6.9Vbattery 7.Client can calibrate the meter by oneself Specifications: 1.Pressure Range:+/-5psi(TL-101) 2.Accuracy:+0.3% FSO (at 25oC) 3.Repeatability: +0.2% (Max+0.5%FSO) 4.Linearity/Hysteresis:+0.29% FSO 5.Response Time:0.5Seconds Typical 6.Over Range Indicator:Hi 7.Under Range Indicator:Lo 8.Operating Conditions:0 to 50oC(32 to 122oF) 9.Storage Conditions:-10 to 60oC (14 to 140oF) 10.11 Selectable units of Measure 11.Max / minimum / average, and with a relative time 12.Large LCD backlit dual display 13.Zeroing, offset, and data compensation 14.Low battery display and automatic shutdown 15.Data Hold and Error code 16.9Vbattery 17.Client can calibrate the meter by oneself OEM is acceptable CE and ROHS are approved Lowest shipping cost could be provided 53X31X36CM/carton 37pcs/carton 10KGS/carton
Features: 1.Light,temperature and humdity measurement 2.Lux and Fc unit switchable 3.Celsius and Fahrenheit switchable 4.Auto range 5.Large LCD with Backlight 6.Data Hold Function 7.Min/Max/Avg Function 8.Detachable Sensor 9.Low Power Consumption Specifications: Light measure range: 0.1 to 200,000 Lux(Fc switchable) Accuracy:¡¨¤4%(0.1 to 10,000Lux);¡¨¤10% above 10,000Lux Resolution:1 Lux/0.1FC Sampling:0.5sec Temperature range:-10~50oC(14 to 122oF) Accuracy:¡¨¤1oC/¡¨¤1oF Humidity range:20%~90%RH Accuracy:¡¨¤5% Operation temperature:0 to 50oC(32 to 122oF) Operation humidity:10 to 90%RH Storage temperature: -10 to 60oC(14 to 140oF) Storage humidity:10 to 75%RH Size:220*55*35mm Weight:220g(included 9V battery) 53X31X36CM/CARTON 30PCS/CARTON 10.72kgs/CARTON
Product description 120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90) Technique Index 1. power: AC220V+10%, 50Hz+1% 2. Output voltage indicator accuracy:
Frequency converters upto 600 hz, servo stabilizers, electrical panels, led lights, industrial stabilizers, transformers, etc..
Electrical Switchgear
SENYUAN Power Distribution Panel provides production and supply control and distribution systems to meet customer requirements. Complete advanced power distribution solutions to solve the complexity of generators and power plants. Single genset output to load with ATS for grid � Single genset synchronized onto grid � Multi-Genset paralleling � Multi-Genset paralleling and synchronization onto grid � Multi-Genset paralleling by Bus Coupling KYN28A-12 Indoor metal-clad withdrawable switchgear LOW-voltage combination switchgear Shandong senyuan new energy technology co. LTD is a high-tech enterprise which produces 1MW to 100MW new energy power plant and integrated electrical control system. The total area of Sen yuan new energy industry covers an area of 76,000 square meters,There are 10 production workshops, each of which occupies an average area of 3000 square meters. Shandong Sen source new energy equipment manufacturing Co., Ltd. has a complete enterprise GB/T 19001-2008/ISO9001:2008 version certification system (square) and China Quality Certification Center CCC certification system, the company is a high-tech enterprise, has 16 industry patents and 16 computer software copyright. Company: Shandong senyuan new energy technology co. ,LTD
SENYUAN Power Distribution Panel provides production and supply control and distribution systems to meet customer requirements. Complete advanced power distribution solutions to solve the complexity of generators and power plants. Single genset output to to load with ATS for grid Single genset synchronized onto grid Multi-Genset paralleling Multi-Genset paralleling and synchronization onto grid Multi-Genset paralleling by Bus Coupling KYN28A-12 Indoor metal-clad withdrawable switchgear LOW-voltage combination switchgear
Introduce Temperature and Humidity Test Chamber is designed for testing the capability of heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, it is suitable for quality control of the industries of electron, electrical equipment, vehicle, metal, foodstuffs, chemistry, building materials, luggage, printing, packaging, etc. Featurers 1)The separation of humidifier circuit from electric circuit improves safety and protects the circuit against the leakage of water supply line. 2)Available in Chinese and English LCD touch screen, easy operation and program. 3)Able to display the relative date and information of the whole operating system in running mode, graphic display. precautions, maintenance and troubleshooting appear on the screen instantly. 4)The Sirocco fan motor provides greater cyclic airflow to avoid dead corner in the chamber so as to obtain an uniform distribution of temperature and humidity. 5)The system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate. 6)Water Supply adopts automatic watering System, Circulating water supply together with water filter.
Introduction Competitive Price Constant Climatic Walk in Chamber used to test various types of materials for their tolerances under condition of heat, cold, dry, humidity. Application: For all types of electronic products quality inspection , electric appliance, andcommunication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries products. Model BRS Series ( 4m~120m specified by user ) Temp-range A:-20~+150, B:-40~+150, C:-70~+150 Humid-range 20% R.H ~98% R.H ( Can specified low temp and low humid ) Temp. Accuracy 0.5 Humid. Accuracy 3%R.H Heating and cooling speed 5/min, 10/min, 15/min (Standard load 5~30Kg Aluminum Ingot ) Interior material Stainless steel SUS304 (mirror) Exterior material Spray-paint zinc plating steel panel Thermal Insulation material Hard polyfoam+ glass fiber Cooling system Cooling by Bitzer semi hermetic compressor Accessories Observation window( double tempered glass), Double-door:0.8x1.8M,Anti-explosion light, Interior LED lighting, control box 1set Safety device Switch, Over voltage protection, over heat protection, over current protection over temperature protection and water-lacking protection for Compressor. More Products Features 1.Used in various rang of temperature and humidity environment,can meet different testing requirements.Adopting BTHC uniqe control method, with safety and accurate temperature and humidity environment. 2.Equipped with high precision digital display temperature and humidity controller 3.Refrigeration circuit performation controlled by temperature setting value automatically,capable of starting up condenser under high temperature,direct cooling. 4.With wide view glass window,easy to observe the testing process. 5.Protection system: Electrical breaker,overheat protection,phase absence protection,water shortage alarm.
ALTITUDE TEST CHAMBER Altitude test chambers combine temperature and altitude with optional humidity for simultaneous environment testing. Features External pressure type box body structure and stainless steel tank design, rational air circulation system and scientific layout of heating, refrigerating system. Adopts international brand of imported parts for cooling system to improve operation reliability High precision and stable performance with touch screen controller, friendly Man-Machine interface. Multiple layers of safety device to easy maintenance. Standards Implement and Met GB11159-89 GB10590-89 GB15091-89 GB/T2423.25-1992 GB/T2423.26-1992 GJB150.0-86 Specifications 1. Dedicatetouch and excellent user experience 2. Unique and compact design, top grade appearance, stable performance and easy operation 3. Can simulate a wide rang of temperature and humidity environments 4. Capable of testing large components, assemblies, and finished products 5. Customized sizes and configurations available 6. One year warranties
GCK low-voltage switchgear is widely used in power plant, substation, power distribution center and PC motor control center MCC factories and high-rise buildings, as AC 50-60Hz, rated voltage 660V and below, rated current is 4000A and below the power supply system, power distribution, motor control, low voltage the distribution of reactive power compensation using device.