Oil Transformer 2500Kva

$9.0k
MOQ: Not Specified
Supplier From Ha Noi, Alabama, Viet Nam
 
Product specifications
Rated power: 2500kVA
Voltage: 22/0,4kV
Winding connection: Dyn11
No-load loss (Po): 1850 W
Short-circuit loss(Pk): 21000 W
Max. no-load current(I0): 1.5%
Short circuit voltage(Uk ): 6%
Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Jan-19-22

Solar Transformers

$2.5k
MOQ: Not Specified
Supplier From Thane, Maharashtra, India
 
1. Inverter duty Solar transformers, suitable for solar load profile.
2. Multi-winding (2 to 6 windings), oil-filled or dry type.
3. 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV.
4. Low-loss, with Aluminum or Copper winding.
5. Electrostatic shield between LV and MV Winding.
6. Fully type tested at internationally recognized laboratory.
7. Designed with high efficiency, environmental friendliness, superior operational reliability and minimal Total Cost of Ownership.
8. Ideally suited for large MW scale solar PV plants.
Jun-23-22

Oil Immersed Transformer 500Kva

$8.0k
MOQ: Not Specified
Supplier From Ha Noi, Alabama, Viet Nam
 
Product specifications
Rated power: 2500kVA
Voltage: 22/0,4kV
Winding connection: Dyn11
No-load loss (Po): 1850 W
Short-circuit loss(Pk): 21000 W
Max. no-load current(I0): 1.5%
Short circuit voltage(Uk ): 6%
Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Apr-28-22

Oil Immersed Testing Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity



High Frequency Voltage Output Voltage

High Frequency Voltage Output Currentm)

Low Frequency Voltage input

Change

Tempera- ture raised

30 minute

V

A

YD G1.5

1.5

50

30

200

7.5

500

10

YD G 3

3

50

60

200

15

500

10

YD G 5

5

50

100

200

25

500

10

YD G10

10

50

200

220/380

50/26

500

10

YD G 20

20

50

400

380

53

500

10

YD G 30

30

50

600

380

79

500

10

YD G 40

40

50

800

380

105

500

10

YD G 50

50

50

1000

380

132

500

10
Apr-09-22

Dry Type Transformer

$7.0k
MOQ: Not Specified
 
2450Kva threee phase dry type transformer

Our products got certificate of ISO9001,ISO14001 and OHSAS18001. And 18 low voltage products get national certificate of CCC. Also our products get quality testing report from China Quality Certification Center(CQC). Our customers include urban distribution network, power station, transformer substation, oil, chemical, railway and big construction companies. And products export to America, Brazil, Peru, Kenya, Ethiopia, India, Myanmar, Vietnam etc. We sincerely welcome all friends from domestic and overseas to come to cooperate and develop together.
2329 Electric Transformers Suppliers
Short on time? Let Electric Transformers sellers contact you.
Mar-06-22
 
All types of DB's available
Mar-06-22
 
outdoor / indoor Transformer Available
Dec-14-21
Supplier From Bhavnagar, Gujrat, India
 
We have available following ships spareparts for Sale:

Product-Caterpiller step up and down transformer
Part no-2N-8378
Oct-21-21

Transformer Oil Chromatography

$770.00 - $15.4k
MOQ: Not Specified
 
Product description

This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc.

Technical index

Temperature control:

a. Chromatographic column chamber temperature

a.1 Temperature control range: room temperature +8 400(Set the temperature increment 1)

a.2 The precision of temperature control: It is±0.1, which is below 200;
Aug-31-21
 
110ACV to 12ACV
220-250ACV TO 12ACV
US/EUR/AUS three standard products
MOQ:100 EA
Package: carton
Aug-13-21
 
EE30 horizontal 6+6pin customer transformers.
Aug-12-21

Transformers

$1.00
MOQ: Not Specified
Supplier From Mumbai, Maharashtra, India
 
Trutech Products owns the vast industry experience and well-aware of the need of todays society. We are engaged in designing and manufacturing a wide range of transformers including Control, Step-down, Three-phase, Isolation, Special Purpose, Auto Transformer, etc. Our models are distinguished from one another in size, shape and volt rating to work on different applications and industries. Backed by a talented and experienced team of engineers, we have always delivered up-to-the mark solution to our clients that fit into their budget and deliver them guaranteed results.
Being the most progressive Transformer Manufacturers in India, we make sure to perform all the quality tests before performing all the safety and standard test before sending it for the shipment. Our transformers are highly demanded in commercial as well as industrial sectors. If you want the same or look for some more details, be in touch with our customer executives that answer all your queries and guide you the right solution that matches your requirements.
Aug-06-21

Standard Current Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
Product description:

standard current transformer is used as a standard for calibrating current transformers, Used as a standard to calibrate current transformer whose accuracy class is two or more lower than itself. The grounding pole of the machine shell must be grounded. To avoid electric shock, the conductor must be connected to the ground

Technical index

1. Temperature: -5-40

2. Relative humidity: 80%

3. Allow long-term work under the rated current; More than 600A across the core.

Feature;

1. The current of standard CT and tested CT must be the same in CT calibration.

2. Follow the given wiring diagram strictly.

3. Test whether the load box is accurate or not before calibrating the transformer.

4. Forbid secondary winding opening during the calibration.

5. Select demagnetization before calibration.Short out the secondary winding before cutting off the power when the demagnetization is finished.

6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Jul-28-21
 
Product Introduction
TKJB - 1200 Six phase voltage and six phase current can be output, which has made it is possiable to be any combition, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out differential test of three-phase transformer

Product Characteristics
1 Meet all field test requirements.The Microcomputer relay protection tester is a standard of six phase current six phase voltage output at the same time the current a/phase 30 voltage125V/phase.Six - phase current in parallel up to 180A.It can not only test the traditional relays and protection devices but also test the modern microcomputer protection especially the transformer differential protection and backup self-switching device the test is more convenient and perfect.
2 All kinds of technical indexes have reached the standard of DL/ t624-1997 "technical conditions of microcomputer test equipment for relay protection" issued by the ministry of electric power.
3 Classic WindowsXP operation interface man-machine interface friendly easy and quick to operate;The high-performance embedded industrial control computer and 8.4-inch TFT true-color display with a resolution of 800-600 provide rich and intuitive information including the current working status of the device and various help information.
4 The native Windows XP system with recovery function to avoid illegal shutdown or misoperation caused by the system crash.
5 The device has an ultra-thin industrial The keyboard and a photoelectric mouse that handles everything just like a PC.
6 The main control board adopts DSP+FPGA structure and 16-bit DAC output which can generate high-density sinusoidal wave of 2000 points per week for the basic wave greatly improving the quality of waveform and improving the precision of tester.
7 High-fidelity linear power amplifier ensures the accuracy of small current and the stability of large current.
8 The Microcomputer relay protection tester with USB interface and PC communication directly without any connection easy to use.
9 Connect to laptop (optional) to run.Laptop computer and industrial computer use the same set of software no need to learn how to operate.
10 It is equipped with the independent auxiliary voltage source output the output voltage is 110V(1A) and 220V(0.6a) respectively.To be used by relays or protective devices that require dc working power.
11 With the function of software self-calibration it avoids the need to open
Jul-25-21

Verification Device Of Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates.



1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display.

2. With computer interface improve the level of office automation and reduce the labor intensity.

3. Can have a large screen display provide a friendly operation interface and rich measurement information.

4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box.

5. Possess good catching measures and be able to promptly inform users of wrong information.

6. This automatic transformer calibration station can reach level 2.

7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.
Jul-23-21

Hl Standard Current Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to the standard current ratio indicated on nameplate
This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling

Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63/(HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
Jul-21-21

Standard Current Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to the standard current ratio indicated on the nameplate
3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling

Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63 /(HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
Jul-16-21

Standard Voltage Transformer

$770.00 - $15.4k
MOQ: Not Specified
 
product brief introduction Product Introduction
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
Jul-15-21

Current Transformer Field

$770.00 - $15.4k
MOQ: Not Specified
 
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
Jul-05-21

Six Phase Universal Secondary

$770.00 - $15.4k
MOQ: Not Specified
 
Product Introduction
TKJB - 1200 Six phase voltage and six phase current can be output, which has made it is possiable to be any combition, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out differential test of three-phase transformer.




Product Characteristics
1 Meet all field test requirements.The Microcomputer relay protection tester is a standard of six phase current six phase voltage output at the same time the current a/phase 30 voltage125V/phase.Six - phase current in parallel up to 180A.It can not only test the traditional relays and protection devices but also test the modern microcomputer protection especially the transformer differential protection and backup self-switching device the test is more convenient and perfect.
2All kinds of technical indexes have reached the standard of DL/ t624-1997 "technical conditions of microcomputer test equipment for relay protection" issued by the ministry of electric power.
3 Classic WindowsXP operation interface man-machine interface friendly easy and quick to operate;The high-performance embedded industrial control computer and 8.4-inch TFT true-color display with a resolution of 800 600 provide rich and intuitive information including the current working status of the device and various help information.
2329 Electric Transformers Suppliers