strain clamp, parallel groove clamp, anchor shackle, armour rod, ball eye, bow stay rod, cable gland, clevis thimble.Supplier and manufacturer
ADSS, OPGW, figure 8, FTTH, indoor, outdoor fiber optic cable, fiber splice closure, fiber optical patch cord, fiber terminal box, fiber distribution box, fiber joint box.
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. BRAND: SCHNEIDER ELECTRIC AND ALL OTHER BRAND AVAILABLE. we are trader of Distribution Transformer and supply all over world. We have 20 Years Experiance Technical team for Desining and Winding of Diffrent types of Transformer. We have 15 Years Experiance Technical Team for Testing of Transformers. We can supply transformer up to 33kV and up to 5000kVA.
GE TRANSFORMER PROTECTION RELAY MODEL :- MUITILIN T60-N11-AKH-F8L-H6N-M8L-P6P U6P-W6;
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG031SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG031SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9125 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG038SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG038SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG039SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG039SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Altrazeal® is a patented powder dressing specially engineered to cover and protect the wound and to provide an ideal moist wound healing environment that supports cellular function and tissue repair. Its non-resorbable, sterile granules aggregate when hydrated with saline to form a moist, flexible, oxygen permeable film that fits and seals the wound. The skin-like barrier serves many functions that promote healthy granulation tissue growth: 1. seals and protects the entire wound surface 2. allows oxygen transportation 3. manages exudate through vapor transpiration 4. prevents penetration of exogenous bacteria Altrazeal® enables extended wear time, allowing the wound to heal without disturbing the wound bed with frequent dressing changes.
Spectrolab M
Spectrolab M
Material & Structure : Bottle will be of robust construction and is made out of SS (304&316 Grade)such that no damage occurs during frequent transportation of samples from site to laboratory. Application &Advantage: Oil Sampling bottles are mandatory as per IS-9434-1992 standard to collect the oil sample only in Stainless Steel Bottle under positive pressure to ensure the proper and correct results of DGA.
Electron Components Chips.
Engine and generator spair, turbocharger spair and kits, compressor and spair, hydraulic item,automation and electric equipment ..
Power supplies, ac dc adapters, power adapter, poe power over ethernet, poe switch, poe injector/splitter/extender, etc..
Oxygen Generator Plant, Nitrogen Generator Plant, Air Handling Unit, Gobargas, Biogas Generator Plant, Engineering Projects.
Plc.him, servo drives, inverters, power supplies, servo motors, controllers and other accessories. .
ROTARY FEEDER FOR BUCKET ELEVATOR BOTTOM ASH XG-100(300X300) Steam turbine parts is a research and development, production, sales, import agents in one of the manufacturing and processing enterprises. Our company was established in 2004. For more than 20 years, our company's products are widely used in electric power, petroleum, chemical, environmental protection, refractory materials, metallurgy, fire fighting equipment, natural gas, electronics, nuclear industry and other fields. Our company is willing to work with colleagues from all walks of life at home and abroad wholeheartedly cooperation to create a better future power plant, steel spare parts are as follows: can offer many spare parts for power plants as below: DF-ROTARY FEEDER FOR BUCKET ELEVATOR BOTTOM ASH XG-100(300X300)-DF sensor lvdt B152.33.01.01(2) temperature probe sensor WZP2-235 Liquid level transmitter LS15 S3F560A Gear speed sensor CS-3F-M16 1-L20 thermal resistance testing WZPK2-213 PT100 thermocouple replacement WRNK-221 platinum rhodium thermocouple wire WRNK2-331T lvdt displacement sensor 5000TDGN-30-01-01 LVDT Displacement Transducer Sensors HL-3-20-15 heating tube element HY-GYY-2.4-380V liquid level gauges 617279-SFQZQ13 linear displacement transducer TDZ-1-44 differential pressure switch 4NN-K5-N4-B1A linear variable displacement transducer ZD-7000TDA transmission speed sensor CS-3-M16-L185 stainless steel Thermocouple DZ3.1.2.7-1992 LVDT Measurement TDZ-1E-42 lvdt working principle C9231015 temperature sensor pt100 WZPK-646 Position indicator 6DR5220-0EN00-0AA0 displacement sensor 2000TDGN-15-01 Thermistor Sensor WZPK2-233 tachometer rpm D421.51UI heater cartridge JHG03SZ-380/6KW displacement transducer K156.36.06.005 Thermocouple Control TKWRE2-230T �?6 lvdt 0-300 ZD-4000TDA linear displacement transducer TDZ-1-04 displacement sensor sany ZDET-400B thermocouple wire TE-109 LVDT Displacement Sensors 7000TDZ-A Gear tooth sensor CS-3-M10-L120 type k thermocouple TE-104 LVDT Sensor TDZ-1E-013 3 wire rtd WZPM2-001 �¦6 lvdt sensor LVDT-150-3 DFYL-2023-4-14-MY