Please click here to check who's online and chat with them.

Find Verified Electric Power Suppliers, Manufacturers and Wholesalers

Aug-25-19
Supplier From Quezon, Metro Manila, Philippines
Jul-07-07
Supplier From Ahmedabad, Gujarat, India
May-19-22
Supplier From Qingdao, China
Mar-04-22
Supplier From Bhavnagar, Gujarat, India
Sep-28-21
Supplier From Ghaziabad, Uttar Pradesh, India
21424 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.
Sep-29-09
Supplier From Vernon, Canada
May-14-01
Supplier From Wendeng City, Shandong, China
Aug-05-22
Supplier From Weifang, Shandong, China
Jun-26-22
Supplier From Singapore
Sep-01-08
Supplier From Taguig, Manila, Philippines
Oct-23-18
Supplier From Greater Noida, Uttar Pradesh, India
Jan-23-23
Supplier From India
Nov-22-24

Transformers

$500.00
MOQ: Not Specified
Supplier From Thane, Maharashtra, India
 
We supply all the types of Transformers per the desired applications and also maintain the international quality standards
Nov-05-24

Toroidal Transformer

$15.00
MOQ: Not Specified
 
The range of toroidal transformers can vary in terms of power capacity, voltage, and mounting style:
Power capacity: Standard toroidal isolation transformers can range from 100 to 5,000 VA.
Voltage: Dual primaries can be configured for 120 V or 240 V operation. Dual secondaries can range from 2 to 12 V windings to 2 to 120 V windings.
Mounting style: Standard mounting for sizes up to 5000 VA is with a single metal centering washer and mounting screw or bolt. Other mounting methods include PCB mounting, DIN rail mounting, and resin center potting with brass inserts.
Toroidal transformers are known for their high efficiency, typically ranging from 95% to 99%. This high efficiency is due to their near-ideal design, which effectively contains the magnetic flux within the windings, eliminating leakage flux.
Nov-05-24

Ferrite Transformer

$5.00
MOQ: Not Specified
 
They are used in electrical applications when the frequency ranges between 2 MHz to several hundred MHz and are suitable for inductors above 70 Mhz. 3. Sand Dust: These are high-frequency Choke Coils ideally used with ferrites only.
Nov-05-24

R Core Transformer

$20.00
MOQ: Not Specified
 
output voltages ranging from 012V, 5Amp
R-core Transformers are manufactured using the unique rectangular core with round cross section known as R-core. The special feature of this transformer is that the core is gap less and continuous. The winding is done on special round bobbins on two parallel legs of the core.
Design
The core is continuous and gapless, with two balanced windings on either side. The winding is done on special round bobbins on the two parallel legs of the core.
Size
R-core transformers are smaller and have a lower profile than E-I core transformers of the same capacity.
Temperature rise
R-core transformers have a lower temperature rise due to the round cross sectional area and tapered slitting.
Noise
R-core transformers have low noise due to the balanced winding and low flux leakage. This makes them suitable for use in noise sensitive equipments.
Leakage flux
R-core transformers have a leakage flux that is about 1/10th of conventional transformers. This allows the transformer to be placed close to critical electronic components.
Nov-05-24

Ei Type Transformer

$10.00
MOQ: Not Specified
 
An EI transformer is a type of transformer with a core made of thin electrical steel sheets that are stacked to form the letters E and I. The primary and secondary windings are wound on bobbins, which are then placed on spindles to apply the windings.
Jun-18-24
 
RF transformer is to achieve the main transformation, coupling and impedance matching of signals in the RF (Radio Frequency) circuit. The following are the main functions of RF transformer.

1. Transformation effect: RF transformers can be used to transform the voltage or current level of signals. By adjusting the ratio of turns on different windings of the transformer, the signal can be stepped up or down to adapt to different RF circuit requirements.

2. Coupling effect: RF transformers can be used to achieve signal coupling and transmission. It can transmit signals from one circuit to another, realizing energy transfer and information transfer between different circuits.

3. Impedance matching: RF transformers can be used to achieve impedance matching to ensure maximum power transfer of signals between circuits. By adjusting the transformer's turn ratio and winding design, impedance matching between the signal source and load can be achieved to minimize signal reflections and losses.

4. Filtering and frequency selection: RF transformers can be used to implement frequency selection and filtering functions. Through the specific design and parameter selection of the transformer, selective transmission and filtering of signals within a specific frequency range can be achieved to meet the frequency selection requirements of the radio frequency circuit.

In general, RF transformers play an important role in RF circuits and are mainly used for functions such as voltage transformation, coupling, impedance matching, and filtering. They are one of the key components for realizing radio frequency signal transmission, conversion and processing, and are widely used in radio frequency applications such as communication systems, radio equipment, broadcasting, radar, and antenna systems.
Jun-18-24
 
RF transformer is to achieve the main transformation, coupling and impedance matching of signals in the RF (Radio Frequency) circuit. The following are the main functions of RF transformer.

1. Transformation effect: RF transformers can be used to transform the voltage or current level of signals. By adjusting the ratio of turns on different windings of the transformer, the signal can be stepped up or down to adapt to different RF circuit requirements.

2. Coupling effect: RF transformers can be used to achieve signal coupling and transmission. It can transmit signals from one circuit to another, realizing energy transfer and information transfer between different circuits.

3. Impedance matching: RF transformers can be used to achieve impedance matching to ensure maximum power transfer of signals between circuits. By adjusting the transformer's turn ratio and winding design, impedance matching between the signal source and load can be achieved to minimize signal reflections and losses.

4. Filtering and frequency selection: RF transformers can be used to implement frequency selection and filtering functions. Through the specific design and parameter selection of the transformer, selective transmission and filtering of signals within a specific frequency range can be achieved to meet the frequency selection requirements of the radio frequency circuit.

In general, RF transformers play an important role in RF circuits and are mainly used for functions such as voltage transformation, coupling, impedance matching, and filtering. They are one of the key components for realizing radio frequency signal transmission, conversion and processing, and are widely used in radio frequency applications such as communication systems, radio equipment, broadcasting, radar, and antenna systems.
Jun-18-24
 
Current transformer is an instrument that converts a large current on the primary side into a small current on the secondary side based on the principle of electromagnetic induction. The current transformer is composed of a closed core and windings. Its primary winding has a small number of turns and is strung in the circuit of the current that needs to be measured.

The principle of current transformer is based on the principle of electromagnetic induction. The current transformer is composed of a closed core and windings. Its primary winding has very few turns and is connected in series in the line where the current needs to be measured. Therefore, it often has all the current of the line flowing through it. Its secondary winding has more turns and is connected in series in the measuring instrument and protection circuit. The current mutual inductance When the transformer is working, its secondary circuit is always closed, so the impedance of the series coil of the measuring instrument and the protection circuit is very small, and the working state of the current transformer is close to the short circuit.
21424 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.