Product description Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters. Feature 1. Current clamp and meter combined together, colorful and touch-screen display; 2. One AAA Li-battery can continuously working 4 hours; 3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A; 4. Display all the measuring parameters in one screen; 5. Current clamp has automatic compensation function, 0.2% class accuracy; 6. Current clamp has automatic calibration function; 7. Integration design of the meter and clamp; 8. 16bit high accuracy AD switch 32 bit ARM processor core. 9. Automatically record and save 999 groups calibrate data; 10. Micro-multifunction optic sampler Technical index 1. Manual/automatic test inductive single phase meters; 2. Manual/automatic test electric single phase meters; 3. Measure virtual value of alternating voltage (15~300Vrms); 4. Measure virtual value of alternating current (50mA~120Arms); 5. Test parameters: active power, phase angle of voltage and current, frequency and etc; 6. Automatic store testing data, and 999 group test results can be saved.
Product description: Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index: Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Electrical parameters - continued Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) �±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Products Introduction Very Low-Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use. Technical Parameter 1 output frequency 0.1Hz 0.05Hz 0.02Hz 0.01Hz 2 Loading capability : Table 1 for reference 0.1 Hz maximum 1.1F 0.05 Hz maximum 2.2F 0.02 Hz maximum 5.5F 0.01 Hz maximum 11.0F 3 accuracy :± (3% of full scale +0.5 KV) 4 voltage waveform distortion 5% 5 condition of use : indoor, outdoor; temperature : -10+40humidity 85%RH 6 power supply AC50 Hz 220V +5% 7 power fuse : output rated voltage Table for reference
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
This instrument is an instrument which is specially used for transformer loss parameters and line frequency parameters testing. The instrument has the advantages of ingenious design excellent performance and powerful functions. The interior adopts advanced multi A/D synchronous sampling and digital signal processing technology and successfully solves the problem of multi-channel signal synchronous measurement and calculation. The instrument adopts large screen liquid crystal display Chinese menu prompt simple operation equipped with high-speed thermal printer and has storage function convenient for data storage and printing. The instrument is small in volume light in weight easy to carry and is very convenient to use in the field. It greatly reduces the labor intensity of the experimenters and improves the working efficiency. 1. Large LCD display simple menu operation. 2. With thermal printer storage function. 3. Small volume and light weight suitable for field work.
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement. 1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ; 2. High Anti-interference ability accurate and reliable measurement; 3. Easy operation equipped with large LCD and American rotating mouse and micro printer 4. Simple wiring only connecting with tested down leads to finish all line parameter measurement 5. High speed micro-controller as inner core integrated structure 6. Fast testing process one sequence parameter testing time is 1 min 7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault. After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent. The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
-86 ULT Freezer 730*845*1400mm87/115kg
Volume (L/cu.ft.):338/11.93; Net Weight/Gross Weight:286/306; Temperature Control Rang:-40~-86 Pull Down Time to -86 at 30 4hrs; Ambient Temperature SN (10 to 32); Controller:Microprocessor; Display:7'' Touchable LCD Display; Temperature Sensor:PTC; Compressors:SECOP/2; Insulation Material:130mm PURF, Vacuum Insulation Panel Plus; Outer Material:Painted Steel; Chamber Material:Stainless Steel; Outer Door:Foam, Sealing joint strip with magnetic force; Outer Door Lock Safety door lock and password protection Power Supplier 220V/50/60HZ, 110V/60Hz.
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests. Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments. 900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
Product Description 450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below. Product Characteristics Rated parameter value Rated nominal voltage±450kV Rated voltage ±150kV Rated energy 20kJ Total impulse capacitance 0.25 F The total series 3 series Rated power capacity 1 F
Product Description ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test. Product Characteristics 1ã??Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control 1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter 2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs 3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability 4. With RS232 and USB(optional) communication interface for PC connection 5. With aluminum alloy carrying box which look nice and with little weight
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation 1) AC/DC analog value input measurement 2) state variables input measurement 3) remote control execution testing 4) remote regulation function testing 5) digital value input testing 6) impulse input testing 2. AC Power source It can output AC voltage AC current accuracy 0.05 class can provide standards of AC/DC voltage/current power phase power factor frequency energy. Output method and output electric quantity can be set arbitrarily 3. Data management It can save search browse print or delete RTU testing data. Calibrated parameters can be saved permanently
Product Description 450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below. Product Characteristics Rated parameter value Rated nominal voltage ±450kV Rated voltage ±150kV Rated energy 20kJ Total impulse capacitance 0.20F The total series 3 series Rated power capacity The following waveforms can be generated when the load capacitance is 300~5000PF 2±30%/50 ±20%s Lightning impulse voltage full waveï¼?The efficiency of voltage 92%(no-load ) standard impulse voltage cut wave 2~6 The efficiency of voltage 92% (no-load) The impulsevoltage waveform parameters all meet the requirements of IEC and GB311-97 national standards Class voltage within 10% ~ 100% rated voltage range positive and negative synchronous range is not less than 20%. Ignition range 10%ï½?100% Synchronous discharge rate out of control 2% Minimum output voltage 10un Charging voltage instability ±1.0% Service duration: > over 70% UN rated voltage can operate continuously every 90 seconds. Under the rated voltage of < 70% UN charging and discharging once every 45 seconds can run continuously.
Product Introduction Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply. product features Product Characteristics 1 the company's Triple frequency transformer is simple to operate reliable performance 2 can well meet the needs of transformers transformers withstand voltage
Product Introduction Insulation boot (glove) withstand voltage is designed and manufactured by our company according to the test procedure of insulated boots (gloves) and in accordance with the opinions of users. Insulation boot (glove) withstand voltage uses automatic (lower) voltage to automatically read out the leakage current of each test item. The whole test process is completed automatically and the test data is automatically printed which effectively solves the irregular test method in the past. This simplifies the testing procedures and improves the testing speed. More reliable identification of the leakage current of the insulated boots (gloves) power frequency withstand voltage and other parameters. It is the ideal equipment for insulating boots (gloves) to ensure the safety of test workers. Its main features: test 6 test items at the same time and read the leakage current of each test item to accurately judge the unqualified test items; the test vehicle is equipped with casters at the bottom for easy movement using a large white light display under strong light Still clearly visible with a one-click shuttle easy to operate with a good interactive experience. product features Product Characteristics 1 automatic and fast: the use of high-fine stepper motor to control the voltage regulator boost process according to the national standard test parameters fully automatic pressure test. After the test starts the instrument automatically closes and automatically boosts the boosting speed according to the national standard. It reaches the scheduled voltage and starts to count and keeps the test voltage. It automatically depressurizes the timer until the preset time. After zero the power is automatically turned off indicating that the test is over. Display each sample leak Current and display the test result 2 full-featured: full Chinese interface work status display simple and clear operation wide application; with status display with reminder function the user can see the status of the device at a glance; rotate the mouse operation all functions can be rotated by one Mouse setting all digital adjustment abandoned the old potentiometer adjustment mode the field is very convenient to use; button directly set the target Voltage leakage Current pressure time application freely 3 intelligent security protection: with Current over the protection of the Voltage. Accurate and fast protection ensuring the safety of personnel and equipment
Product Introduction 3-phase energy meter calibrator introduction: HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. Product Characteristics 3-phase energy meter calibrator introduction: TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. 3-phase energy meter calibrator technical parameters: Input feature Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range. Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional) Phase angle measuring range: 0 ~ 359.999 Frequency Measurement Range: 45 ~ 55Hz.
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control 1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter 2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs 3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability 4. With RS232 and USB(optional) communication interface for PC connection 5. With aluminum alloy carrying box which look nice and with little weight