Please click here to check who's online and chat with them.

Find Verified Electric Power Suppliers, Manufacturers and Wholesalers

Jul-14-22
 
Technical Parameter
Rated Voltage
& Frequency 400VAC; 3 phase 4 wire, 50/60Hz
Max Load Power 510kW at 400V
Load Steps Resistive Load: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200kW
Power Factor 1
Load Tolerance (each step) 5%
Load Tolerance (overall) 3%
Display Meter Multiple function meter
Fan Control Power External power 380VAC 3 phase 4 wire 50Hz
Wire Connection Load bank input busbar (star coupling )
Control power input terminal block
Communication Interface RS232/RS485
Insulation F
Way of Working Continuous Working
Cooling Forced air, horizontal air intake and exhaust cooling, there will be louver at air outlet and inlet
Transportation With lifting eyes and wheel castors
Color Gray RAL7035 or yellow
Dimensions 1800*1300*1070mm LWH
Weight 700kgs
Operating Environment Parameter
Ambient Temperature 20C50C
Using Place Outdoor
Altitude 2500 meters
Relative Humidity 95%
Atmospheric Pressure 86 106kPa
Brands of Main Components
Contactor
Fuse MIRO
PLC Siemens
Alloy Resistor
Data Processing Software
Aug-22-21
Supplier From United States
Mar-11-22
 
Overview

Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.

I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.

CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.

Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.

220V single power input and avoids the risk of using 380V.

Current transformer volt-ampere characteristic tester



Main Technical Parameters:

Booster output current & voltage

1A/2500V



2A/1500V



5A/600V



10A/220V



20A/30V

Current generator output current

600A

Output power

3000VA

Voltage and current measurement accuracy



CT ratio tests

Range

1 -40000

Voltage method / current method

Accuracy




PT ratio tests

Range

1 - 40000

Accuracy
Apr-11-25
Supplier From Dongguan, Guangdong, China
Apr-24-09
Supplier From Ningde, Fujian, China
22015 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.
Dec-22-09
Supplier From Fuan, Fujian Province, China, China
Nov-16-12
Supplier From Bhuj, Gujarat, India
Mar-25-15
Supplier From Lahore, Sindh, Pakistan
Feb-01-12
Supplier From Ratchaburi, Photaram, Thailand
Sep-08-14
Supplier From Wenzhou, Zhejiang, China
Sep-01-22
 
Overview

The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.



Technical parameter

Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature
Apr-01-22
 
This instrument is a high precision DC energy meter test equipment.The highest accuracy is 0.02%. And it has wide test range 0-115V and 0-600A. It mainly test the DC energy meter error.
Features:
1.test all kinds of DC energy meter,DC power meter
2.Accuracy: 0.02%,0.05%
3.Portable design
4.Can store 10000pcs meter data
5.Overload, short circuit,open circuit protection
May-09-22
Supplier From Tianjin, China
May-25-09
Supplier From Gijang Gun, Busan, South Korea (Republic Of Korea)
Dec-08-11
Supplier From Changsha, Hunan, China
Mar-25-14
Supplier From Yueqing, Wenzhou, China
Mar-19-20
Supplier From Singapore, Singapore
May-02-14
Supplier From Mumbai, Maharashtra, India
Apr-26-19
Supplier From China, China
May-17-23
 
Model G500
Rated power 500W
Rated capacity(Wh) 519Wh
Standard capacity 3.7V/140400mAh
Overload protection(W) 550 40W
Battery Cell Type 16850
Input AC Charging input Voltage 12-26V
Solar charging Support
Car Charger 14V/8A
Output Output waveform Pure sine wave
AC Output 110V 10%/60HZ
USB Output QC3.0/18W
Type-C PD60W
Cigarret lighter 14V/8A
DC55 2.5 14V/8A
DC55 2.1
Wireless charging Support
Other Functions Bluetooth
LCD Display Support
Music U Disc
LED Lighting Support
PD Quick charging Support
AC output sockets USA, JAPAN, EUROPE, AND AUSTRALIA standard optional
Color orange+black
Working temperature 10-40
Net weight 6.8kg
Gross weight 7.8kg
Dimension: 312 190 190mm
Protections BMS
OEM&ODM. Acceptable
MOQ 1Pieces
warranty 1 YEAR
22015 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.
See what buyers and suppliers are discussing in Electric Power import export community