Please click here to check who's online and chat with them.

Find Verified Electric Power Suppliers, Manufacturers and Wholesalers

VERIFIED
Jun-19-21
Supplier From Anand, Gujarat, India
 
ALSTOM GBCDG61EG038SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG038SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Aux.conts.with flag. 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 1.3 secs
Current setting - E/F 0.2 to 0.8 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 2 to 8 amps
High set & conts with flag CAG 13 / 2M S/R
Name plate RFG9125 902
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-19-21
Supplier From Anand, Gujarat, India
 
ALSTOM GBCDG61EG039SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG039SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Aux.conts.with flag. 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 1.3 secs
Current setting - E/F 0.1 to 0.4 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 2 to 8 amps
High set & conts with flag CAG 13 / 2M S/R
Name plate RFG9125 901
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
May-03-19
Supplier From New Delhi, Delhi, India
 
Altrazeal® is a patented powder dressing specially engineered to cover and protect the wound and to provide an ideal moist wound healing environment that supports cellular function and tissue repair. Its non-resorbable, sterile granules aggregate when hydrated with saline to form a moist, flexible, oxygen permeable film that fits and seals the wound.



The skin-like barrier serves many functions that promote healthy granulation tissue growth:

1. seals and protects the entire wound surface

2. allows oxygen transportation

3. manages exudate through vapor transpiration

4. prevents penetration of exogenous bacteria


Altrazeal® enables extended wear time, allowing the wound to heal without disturbing the wound bed with frequent dressing changes.
VERIFIED
Feb-14-14

Spectrolab M

$25.00K
MOQ: Not Specified
Supplier From Navi Mumbai, Maharashtra, India
 
Spectrolab M
VERIFIED
Feb-14-14

Spectrolab M

$25.00K
MOQ: Not Specified
Supplier From Navi Mumbai, Maharashtra, India
 
Spectrolab M
21587 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.
VERIFIED
Mar-25-13
Supplier From Banaglore, Karnataka, India
 
Material & Structure : Bottle will be of robust construction and is made out of SS (304&316 Grade)such that no damage occurs during frequent transportation of samples from site to laboratory.
Application &Advantage: Oil Sampling bottles are mandatory as per IS-9434-1992 standard to collect the oil sample only in Stainless Steel Bottle under positive pressure to ensure the proper and correct results of DGA.
Feb-22-25
Supplier From Bhubaneswar, Odisha, India
Feb-25-25
Supplier From Cangzhou City, Asia, China
Oct-24-13
Supplier From Brea, United States
Mar-24-21
Supplier From Dhaka, Dhaka, Bangladesh
Mar-10-21
Supplier From Vadodara, Gujarat, India
Nov-28-19
Supplier From Pakistan, Pakistan
Apr-26-19
Supplier From Delhi, Delhi, India
Jan-27-05
Supplier From Mumbai, Maharashtra, India
Nov-05-03
Supplier From Yuyao, Zhejiang, China
Aug-31-21
Supplier From Beirut, Lebanon
Dec-02-05
Supplier From Chengdu, Sichuan, China
Jun-11-07
Supplier From Shanghai, China
Aug-07-14
Supplier From Cangzhou, Hebei, China
21587 Electric Power Suppliers
Short on time? Let Electric Power sellers contact you.