GE TRANSFORMER PROTECTION RELAY MODEL :- MUITILIN T60-N11-AKH-F8L-H6N-M8L-P6P U6P-W6;
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG031SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG031SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9125 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG038SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG038SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG039SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG039SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Aux.conts.with flag. 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set & conts with flag CAG 13 / 2M S/R Name plate RFG9125 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Altrazeal® is a patented powder dressing specially engineered to cover and protect the wound and to provide an ideal moist wound healing environment that supports cellular function and tissue repair. Its non-resorbable, sterile granules aggregate when hydrated with saline to form a moist, flexible, oxygen permeable film that fits and seals the wound. The skin-like barrier serves many functions that promote healthy granulation tissue growth: 1. seals and protects the entire wound surface 2. allows oxygen transportation 3. manages exudate through vapor transpiration 4. prevents penetration of exogenous bacteria Altrazeal® enables extended wear time, allowing the wound to heal without disturbing the wound bed with frequent dressing changes.
Spectrolab M
Spectrolab M
Material & Structure : Bottle will be of robust construction and is made out of SS (304&316 Grade)such that no damage occurs during frequent transportation of samples from site to laboratory. Application &Advantage: Oil Sampling bottles are mandatory as per IS-9434-1992 standard to collect the oil sample only in Stainless Steel Bottle under positive pressure to ensure the proper and correct results of DGA.
Energy meter test equipment, ct pt analyzer, relay tester, three phase standard power source, reference energy meter, electrical calibrator, power quality analyzer, power transformer test equipment, circuit breaker tester, high voltage ammeter recorder, high voltage test set, ev & recharging testing equipment, substation iec61850 test software, intelligent digital power meter and transducer, current probe & current sensor, split core ct, instrument current transformer & voltage transformer, micro ct & pt, energy meter relay parts, and handheld terminal.
MCCB, acb, contactors, relay, switches & controls, fuse materials, surge voltage protection, transformers, inductors, power supply units, counters & meters and enclosures.
Reactors, dry type reactors, harmonic filters , series reactors, shunt reactors, peterson coils, neutral earthing reactors, earthing transformers , power transformers.
Relay, shunt, current transformer.
Rotary switch, cotact element led indicators limit switch push button station junction boxes current transformers dc shunts fuse base fuse hollders industrial hooters electronic buzzers, push button.
Reactors and transformers.
Three-phase relay test set, AC high voltage test set, winding resistance test set, transformer capacity and power loss test set, current transformer test set, cablefault test set.
Rj 45 connector and lan transformer.OEM,ODM
Rogowski coil, integrator, current transformer, current sensor.