6GHz intelligent radar level gauge is suitable for non-contact continuous measurement of liquid, slurry, granular and bulk materials. It is suitable for temperature, pressure change, inert gas and volatilization. The measurement method of microwave pulse is adopted, and it can work normally in the range of industrial frequency band. Low beam energy, can be installed in a variety of metal, non-metal containers or pipes, no harm to the human body and the environment. Application:Simple corrosive liquid in the process Skyline:PTFE Measuring range: 20 meters Frequency range: 6.8GHz Accuracy: 0.1%FS Medium temperature: -40 to +130 °C Process pressure: -0.10.3Mpa Power supply: 24vDC (two-wire, four-wire optional) Signal output: 4...20mA/HART (two lines/four lines)/ RS485/Mod bus Process connection:Thread Protection level: IP67 Explosion-proof grade: Exia IIC T6 Ga
High Frequency Radar Level Meter Design features: Small antenna size, easy to install; non-contact radar, no wear, no pollution Hardly affected by corrosion or foam; hardly affected by changes in water vapor, temperature and pressure in the atmosphere. Severe dust environment has little influence on the work of high frequency level gauge. Shorter wavelength, better reflection on inclined solid surfaces The beam angle is small and the energy is concentrated, which enhances the echo ability and helps to avoid the interference. The measurement blind area is smaller, and good results can be obtained for small tank measurement. High signal-to-noise ratio, even in the case of switching, can achieve better performance High frequency is the best choice for measuring solid and low dielectric constant medium Application: various corrosion liquid Antenna material: PTFE Measurement range: 10 m Process connection: thread, Flange Medium temperature: -40C --130 Process pressure:-0.1~0.3MPa Accuracy: ±5mm Power supply: 24VDC (two lines, four lines) Protection grade: IP67 Frequency range: 26GHz Explosion-proof grade: Exia C T6 Ga/ Exd ia IIC T6 Gb Signal output: 4. 20mA/HART (two / four) RS485/Mod bus
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests. Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments. 900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
Three Phase AC Voltage Regulator - BRAND - VIJAYANTA, INDIA 1. Study of Three Phase AC Voltage Regulator, Model: TPACâ??408A
Key Features: Aluminum alloy housing|Strong|Anti-explosion 1.Built in High Power Density Lithium Polymer Batteries; 2.Up to 40Ah/11.1V(equivalent: 120000mAh,3.7V)444Wh Battery power; 3.AC Pure SineWave output; 4.Up to 450W AC continuous output; 5.Tripple DC outputs and Cart port, Up to 150W Peak power for car kits, Lamps, fans,etc., 6.Support 3 x 5V/2.1A and 1 x USB Type C 15.5W Output for Smart phones, tablets,etc., 7.Suport 1 x USB Type C with PD 40W for Laptops. 8.Protection including: Shortcircuit,Overload,Over temperature proof etc.,
product brief introduction Product Introduction series is the equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through which completely overcome the problems of long blow water time bottom water hard to dry easy to cause arcing within the coil. The device is light simple wiring and easy to read. Polarization compensation voltage is output directly by the case. product features Product Characteristics 1. Electronic control and tune easy to operate. 2. The date of voltage and current are recorded in the panel reading without conversion. 3. One minute timing and tip function. 4. Perfect over-voltage and over-current protection function inside also zinc oxide over-voltage protection outside which ensure safety of generator. 5. Portable design suitable for on-site testing. 6. Four parts separated: control unit Intermediate Frequency Transformer doubler and accessories all packed with special shockproof aluminum alloy cabinet easy to move.
Warranty: 12 months Certification: ce Place of Origin: Guangdong, China Brand Name: rawsuns Model Number: Six in one integrated control system insulation grade: H grade IP Grade: IP67 rated capacity: 60kw Maximum capacity: 120kw overvoltage protection: 720V Under-voltage protection: 380V Rated Voltage: 540VDC maximum input voltage: 700VDC Application: 4.5 tons commercial vehicles, light passenger cars
Product Introduction TKJF fit for many products it has high sensitivity high S/N a large screen which has clear testing wave displaying high frequency ellipse scan (the power is less than 1VA). auxiliary zero marking system. The discharge meter has pointer/digital display and linearity /digital function. The amplifier has large dynamic range 9 kinds of frequency band combinations. TKJF is a powerful tool for developing new high voltage electric products and improving the quality of the products. It is also an efficient testing device to judge the work condition of equipments on the work field. This device is used together with model JZF-9 or JZF-10 calibrator. product features Product Characteristics Working Principle When measured piece Cx has partial discharge under testing voltage the circuit will have pulse current which get by the input unit. The pulse signal is amplified by front amplifier and the frequency band is chose by filter amplifier then been amplified to needed amplitude by the main amplifier. The pulse signal will be displayed on oscillograph screen. The pulse value is also sent to the pulse peak meter and displayed immediately. The time window unit chooses a working period of the pulse peak meter during each cycle of testing voltage and it increases the brightness of the relevant displaying area in this time. In this way it can avoid the disturbing of fixed phase. Input discharge volume to the measured piece Cx through JZF series PD external calibrator adjust the fine adjusting knob till the displayed value is equal to the discharge volume the discharge can be read directly and conveniently on the meter without counting. The testing voltmeter will have an over zero mark signal of testing voltage through the voltmeter resistance R and the zero mark pulse will be displayed on oscillograph screen. The testing voltage can be displayed on KV meter.
Product Introduction The product combines modern advanced digital variable frequency technology and microcomputer control together therefore it can realize the full automatic voltage boost step down measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display and can display the output wave form. Product Characteristics VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus. 1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate. 2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms. 3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms. 4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Product Description ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test. Product Characteristics 1ã??Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use. 2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1µA, shock resistance current 0.1µA. 3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site . 4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance. 5 75% MOA voltage switch button, simple and convenient testing arrester. 6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments. 7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
Product Description 450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below. Product Characteristics Rated parameter value Rated nominal voltage ±450kV Rated voltage ±150kV Rated energy 20kJ Total impulse capacitance 0.25F The total series 3 series Rated power capacity1F
Product Description ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test. Product Characteristics 1 Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use. 2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1�µA, shock resistance current 0.1µA. 3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site . 4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance. 5 75% MOA voltage switch button, simple and convenient testing arrester. 6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments. 7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
1 Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use. 2 Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1 A, shock resistance current 0.1 A. 3 The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site . 4 High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance. 5 75% MOA voltage switch button, simple and convenient testing arrester. 6 Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments. 7 Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply. 1 the company's Triple frequency transformer is simple to operate reliable performance 2 can well meet the needs of transformers transformers withstand voltage
Insulation Resin Impregnated Paper/ Synthetic Rated Voltage 24kV 245 kV Rated Current Up to 6300 A Standards IEC-60137:2017 Connection Draw lead/Draw rod/Stem type Housing Silicon/Hollow Composite
Rated Voltage 24kV 170 kV Rated Current Up to 4000 A Standards IEC-60137:2017/ANSI/IEEE Connection Draw lead/Draw rod/Stem type Housing Porcelain/Composite
Specifications: Size 15.87 mm, Lenght 50 m.
Please see our catalog on our website.
1. 5 LED digitally display output by actual value or by percentage 2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional) 3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V 4. Three AC frequencies for option: 50Hz 60 Hz 400 Hz 5. Auto protection or manual resetting function for over load 6. Over load rang is 10% for each level of voltage current 7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software 2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion 3. RAM system large color LCD display massive information can be seen directly through screen 4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency 5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm 6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional) 7. With 485 communication interface can do various communications test for universal meters