Power Transmission Steel Towers are used for electrical transmission and distribution. It is set up outdoor, including many types for 110-500 KV electricity transmission lines.
Product description: Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices. Major Technical Index 1. Environmental conditions Temperature 5 40 Humidity:
PRODUCT FEATURE:- Rain Proof 100% Full load Built-in Test Forced air cooling by Built-in DC ball bearing fan 1 year Warranty LED Indicator for Power On
Product Introduction: AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on. xc control cabinet Technical Paramenters: environment temperature 0-40 altitude < 100m relative humidity < 85% Main product specifications type specification capacity power source output operating mode Refer to the weight anthroposcopy (V) (A) (V) (A) XC-2 2 1 220 50 0-220 10 manual operation 14 XC-3 3 1 220 50 0-220 15 manual operation 16 XC-5 5 1 220 50 0-220 20 manual operation 18 xc
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
This instrument is an instrument which is specially used for transformer loss parameters and line frequency parameters testing. The instrument has the advantages of ingenious design excellent performance and powerful functions. The interior adopts advanced multi A/D synchronous sampling and digital signal processing technology and successfully solves the problem of multi-channel signal synchronous measurement and calculation. The instrument adopts large screen liquid crystal display Chinese menu prompt simple operation equipped with high-speed thermal printer and has storage function convenient for data storage and printing. The instrument is small in volume light in weight easy to carry and is very convenient to use in the field. It greatly reduces the labor intensity of the experimenters and improves the working efficiency. 1. Large LCD display simple menu operation. 2. With thermal printer storage function. 3. Small volume and light weight suitable for field work.
Transmission Line Test System is a new generation power transmission line frequency parameter testing system. It equips with frequency conversion testing power DFT Digital Filtering Technique which eliminates strong interference from power frequency electric field and ensures the safety of equipment convenient fast and accurate measurement. 1. Quickly and accurately test the positive sequence capacitance the positive sequence impedance zero sequence capacitance zero sequence impedance also can measure the mutual inductance and coupling capacitance between lines ; 2. High Anti-interference ability accurate and reliable measurement; 3. Easy operation equipped with large LCD and American rotating mouse and micro printer 4. Simple wiring only connecting with tested down leads to finish all line parameter measurement 5. High speed micro-controller as inner core integrated structure 6. Fast testing process one sequence parameter testing time is 1 min 7. Supplied with three groups different frequency power supply for selection: 42.5Hz/57.5Hz 45Hz/55Hz 47.5Hz/52.5Hz easily isolate the power frequency and noise wave to ensure high precision measurement of small signals.
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault. After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent. The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
-86 ULT Freezer 730*845*1400mm87/115kg
Volume (L/cu.ft.):338/11.93; Net Weight/Gross Weight:286/306; Temperature Control Rang:-40~-86 Pull Down Time to -86 at 30 4hrs; Ambient Temperature SN (10 to 32); Controller:Microprocessor; Display:7'' Touchable LCD Display; Temperature Sensor:PTC; Compressors:SECOP/2; Insulation Material:130mm PURF, Vacuum Insulation Panel Plus; Outer Material:Painted Steel; Chamber Material:Stainless Steel; Outer Door:Foam, Sealing joint strip with magnetic force; Outer Door Lock Safety door lock and password protection Power Supplier 220V/50/60HZ, 110V/60Hz.
Product Description 450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below. Product Characteristics Rated parameter value Rated nominal voltage±450kV Rated voltage ±150kV Rated energy 20kJ Total impulse capacitance 0.25 F The total series 3 series Rated power capacity 1 F
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control 1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter 2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs 3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability 4. With RS232 and USB(optional) communication interface for PC connection 5. With aluminum alloy carrying box which look nice and with little weight
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation 1) AC/DC analog value input measurement 2) state variables input measurement 3) remote control execution testing 4) remote regulation function testing 5) digital value input testing 6) impulse input testing 2. AC Power source It can output AC voltage AC current accuracy 0.05 class can provide standards of AC/DC voltage/current power phase power factor frequency energy. Output method and output electric quantity can be set arbitrarily 3. Data management It can save search browse print or delete RTU testing data. Calibrated parameters can be saved permanently
Product Introduction Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply. product features Product Characteristics 1 the company's Triple frequency transformer is simple to operate reliable performance 2 can well meet the needs of transformers transformers withstand voltage
Product Introduction Insulation boot (glove) withstand voltage is designed and manufactured by our company according to the test procedure of insulated boots (gloves) and in accordance with the opinions of users. Insulation boot (glove) withstand voltage uses automatic (lower) voltage to automatically read out the leakage current of each test item. The whole test process is completed automatically and the test data is automatically printed which effectively solves the irregular test method in the past. This simplifies the testing procedures and improves the testing speed. More reliable identification of the leakage current of the insulated boots (gloves) power frequency withstand voltage and other parameters. It is the ideal equipment for insulating boots (gloves) to ensure the safety of test workers. Its main features: test 6 test items at the same time and read the leakage current of each test item to accurately judge the unqualified test items; the test vehicle is equipped with casters at the bottom for easy movement using a large white light display under strong light Still clearly visible with a one-click shuttle easy to operate with a good interactive experience. product features Product Characteristics 1 automatic and fast: the use of high-fine stepper motor to control the voltage regulator boost process according to the national standard test parameters fully automatic pressure test. After the test starts the instrument automatically closes and automatically boosts the boosting speed according to the national standard. It reaches the scheduled voltage and starts to count and keeps the test voltage. It automatically depressurizes the timer until the preset time. After zero the power is automatically turned off indicating that the test is over. Display each sample leak Current and display the test result 2 full-featured: full Chinese interface work status display simple and clear operation wide application; with status display with reminder function the user can see the status of the device at a glance; rotate the mouse operation all functions can be rotated by one Mouse setting all digital adjustment abandoned the old potentiometer adjustment mode the field is very convenient to use; button directly set the target Voltage leakage Current pressure time application freely 3 intelligent security protection: with Current over the protection of the Voltage. Accurate and fast protection ensuring the safety of personnel and equipment
Product Introduction 3-phase energy meter calibrator introduction: HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. Product Characteristics 3-phase energy meter calibrator introduction: TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. 3-phase energy meter calibrator technical parameters: Input feature Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range. Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional) Phase angle measuring range: 0 ~ 359.999 Frequency Measurement Range: 45 ~ 55Hz.
This device adopts advance ARM+FPGA high precision D/A conversion and DDS technologies can set up and regulate parameters of voltage current frequency phase etc in a long period of time via analog closed loop feedback and digital PID control 1. Can be used to test errors and variance caused by voltage current waveform or power factor change for a variety of metering instrument such as energy meter voltmeter ammeter wattmeter frequency meter power factor meter phase meter 2. Can generate distorted wave with 2~32 order harmonic harmonic number order amplitude and phase position to base wave can be controlled by programs 3. Operational amplifier work frequency 40HZ~1kHz good linearity dual output protection High fidelity output signal and high shock-proof ability 4. With RS232 and USB(optional) communication interface for PC connection 5. With aluminum alloy carrying box which look nice and with little weight
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software 2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion 3. RAM system large color LCD display massive information can be seen directly through screen 4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency 5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm 6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional) 7. With 485 communication interface can do various communications test for universal meters
1. Design with touch panel and mask button massive information to see and simple to use 2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference 3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection 4. Three phase rated current rated voltage can be preset by users 5. Multiple choose of voltage current phase testing point 6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters 7. Large memory for data storage and searching data is very convenient 8. With R232 communication interface for PC control and software upgrade
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation 1) AC/DC analog value input measurement 2) state variables input measurement 3) remote control execution testing 4) remote regulation function testing 5) digital value input testing 6) impulse input testing 2. AC Power source It can output AC voltage AC current accuracy 0.05 class can provide standards of AC/DC voltage/current power phase power factor frequency energy. Output method and output electric quantity can be set arbitrarily 3. Data management It can save search browse print or delete RTU testing data. Calibrated parameters can be saved permanently