Thyristor, rectifier, diode, IGBT, GTO, Triacs, insulation, electro ceramics.
Wireless telecom RF communication antenna, RF coaxial cable, RF coaxial cable connectors.
Electric energy meter, power meter, energy meter, kwh meter, watt hour meter, electronic measuring and testing, PCB assembly, smart control products.
Connectors, relays, switch.
Switches, sockets, plugs..
Electrical & electronic products like epoxy molded components, pantograph insulators, third rail insulators, high voltage insulators, fuse cutouts, medium voltage insulators, epoxy bushing & insulator, gas insulated switchgears & detecting systems & solar pv modules, transformer bushing.Design, and manufacture
Low voltage switch gear, motors, wires & cables, bus bar trunking system, power factor component, enclosures system, brakes, protection devices, led lights, modular switches, fans, accessories & automation products.
Connectors, plugs, AC socket, switch, wire harness, terminal, cable assembly, FFC, FPC, adapters, cables, wireless charger, data cable.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Rated power: 320kVA Winding connection: Dyn11 Frequency: 50Hz Voltage: 22/0,4kV No-load losses (Po): 390 W Short-circuit losses(Pk): 3330 W Maximum no-load current(I0): 2% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN Quality standard: ISO 9001:2015; ISO 14001:2015
Product Description WDS308 Integrated dust monitoring sensor is a specialized small instrument applied to monitor dust at construction sites. It can monitor eight meteorological elements, wind speed, wind direction, air temperature, air humidity, air pressure, rainfall, radiation, UV index, and can also monitor three environmental factors, PM2.5, PM10 and noise. The system is modularized and can be configured flexibly. Small volume, low cost, and it suitable for industrialized intensive stationing monitoring. Features l Maintenance free design l Standard output protocol RS485 l Small volume, light weight l Installation height is unrestricted l Low power consumption, high precision l Integrated dust monitoring system l China's first production company
Rectifier R50030G1 is a high efficiency and high power density 15kW AC DC rectifier. It supports 3 phases 260Vac 456Vac input voltage and 500Vdc nominal output. It is built in an isolated CAN bus port to communicate with the control unit using CAN protocol. The output can be adjusted through the control unit. Features including soft start, input output protection, low noise, and parallelable
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Solar street light, solar torch, solar power plant, solar water heater, solar management unit, solar dc ups, solar dc table fan, solar panel, solar pcu, led bulb, panel light, junction box round, solar lantern, solar home lighting system, electronic ballast, tube set, water overflow alarm, electric iron, stabilizer.
Led strip, led neon strip.
Led grow lights.
Led serial lights.
Led light.Production
Mining and locomotive industries driver system spare parts, like igbt ge1255 17fm796a1, igbt driver board 41a296305edp1, igbt mbn1200e25c ,ge1256 17fm797a1 ,power supply, ps 17fh43a2/a3, sutable for komatsu haul truck like 730e , 830e, 930e.
If any of you have electric transformer electric motor scrap electric panel board for sell then you can contact me..