8 Isolation with differential AC Input (max. 80VAC), with LED * Support 8 isolated differential AC digital input * EMS Protection (IEC-61000-4-2 (EDS)Level 4) * Programable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-9050AB Ethernet ISO 12 DI (wet contact) / 6 DO module * Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP * Ethernet 10/100 Based-T Communication * Support 6 Isolated digital output channels (NPN). * Provide Pulsed/delay Output Mode * Support 12 Isolated digital Input Channels * Provide Counter/ Frequency Inputs Mode * Support Wet Contact Inputs * Fully Photo-Isolation 3750Vrms * Status LED indicator
14 Channels Isolated Digital Input Module * Support 8 non-isolated digital output *Open Collector Output (NPN) * 14 Isolated Single-Ended input channels * Input channel support max. 50Hz counter * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
16 Ch. Non-Isolated Digital Output * Support 16 non-Isolated digital output ch. * Open Collector Output (NPN) * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format Protocol
4-ch ISO DI and 4-ch relay Output with LED display * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Support 4 relay output channels(RL1~RL4) * RL1,RL2: Form A, RL3,RL4: Form C * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
5-ch ISO DI and 5-ch DC-SSR Output with LED display * Support 4 isolated digital input channels * Input channel support max. 50Hz counter * Support 5 DC-SSR output channels * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-8015 6-ch ISO RTD Input module * Support PT100, PT1000, Balco 500, NI604, NI1000 RTD types * Protocol MODBUS RTU, ASCII Command * Support isolated input channels * Fully photo-isolation 3750Vrms * Wide supply voltages (10_30V) * Built-in TVS/ESD protection * Burn-out auto detection
EDAM-8018A 8 Isolated Analog/Thermocouple Temperature Input Module * Support Thermocouple J.K.T.R.S.E.B.N.C Type * Protocol MODBUS RTU, ASCII Command * Support Isolated input channels * Fully photo-isolation 3750Vrms * Wide supply voltages (10-30V) * Built-in TVS / ESD protection * Burn-out auto detection
4 analog output and 4 digital input channels module * 4 isolation analog output channel . * 14 bits Analog Resolution * Programmable voltage/current range with slew rate. * 4 channels isolation digital input * 3000 Vrms isolation voltage for A/O channel * Programmable power-on value and safe value * Programmable host watchdog timer for host failure protection. * Support ASCII format and Modbus-RTU protocol
13 Channels Isolated Digital Output Module * 13 Isolated Single-Ended output channels * Open Collector Output (NPN) * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
8 Non-Isolated digital input and 8 Non-Isolated digital output (NPN) * Support 8 non-Isolated digital output *Open Collector Output (NPN) *Support 8 non-isoloated digital input channels *Input channel support max.50Hz counter * Programmable Host Watchdog Timer for Host Failure Protection *Support Modbus RTU and ASCII Format Protocol
8 Isolation with differential AC Input (max. 250VAC), with LED * Support 8 isolated differential AC digital input * EMS Protection (IEC-61000-4-2 (EDS)Level 4) * Programable Host Watchdog Timer For Host Failure Protection. * Support MODBUS And ASCII Format Protocol
EDAM-9061A 6-channel Digital Input and 6 RELAY (0.6A/AC, 2A/DC) Output module * Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP * Ethernet 10/100 Based-T Communication * Support 6 relay channels. (Form A) * Provide Auto-Off Time of digital output * Support Automatic DIO Synchronization func. * Support 6 Isolated digital Input Channels * Provide Counter Inputs Mode * Support Dry/Wet Contact Inputs * Provide PoE function(only for EDAM-9461) * Fully Photo-Isolation 3750Vrms
EDAM-8000 series: RS-485 Digital and Analog I/O Remote Control Modules Overview: EDAM-8000 is a series of data acquisition modules. It provides a total solution of the data acquisition network and control system. Including the communication modules, the analog input modules, the analog output modules, and the digital I/O modules. You can remotely control up to 256 EDAM modules on RS-485 network.
PU Squeegees electronic printing squeegees Material: polyurethane Hardness: 55 A, 60, 65, 70, 75, 80, 85, 90, 95 SHORE A polyurethane Squeegees Thickness: 2 - 20mm Profile: straight square edge, single bevel, double bevel High precise LCD printing squeegees Length: 4000mm Color: red, green, natural, blue, white Width: 9mm - 500mm Size: 50*9mm, 55*9mm, 45*9mm, 50*7mm, 45*7mm, 40*7mm, 55*5mm, 50*5mm, 45*5mm, 40*5mm, 35*5mm, 25*5mm. Feature: a. High resistance b.Excellent resistance and minimum swell c.Ultra high durability-longer lifespan d.Precisely finished edges e.Super solvent resistance It is widely used in textile screen printing, high precise LCD, electronic printing, large advertisement, auto-printing machine, high precise multi-layered circuit board ect. High precise LCD printing squeegees and polyurethane squeegees are our main product. Our product are widely used in textile screen printing, high precise LCD, electronic printing and so on. More information you can view here
Power distribution unit
PTC thermistors current protector, also called PTC thermistor resettable fuses, protect load against over-current, overload, short circuit. No need for replacement, resume protective function after a short cooling-down time. Ceramic PTC (positive temperature coefficient) thermistors are used instead of conventional fuses to protect load, such as motors, transformers, or electronic circuit, against overcurrent for circuit protection. PTC thermistor protector not only respond to inadmissibly high currents but also if a preset temperature limit is exceeded. PTC thermistor over-current protector limits the power dissipation of the whole circuit by increasing their resistance and thus reducing the current to a harmless residual value. In contrast to conventional fuses, PTC thermistor resettable fuses do not have to be replaced after elimination of the fault but resume their protective function immediately after a short cooling-down time. PTC Thermistor Over-current Protector Application It applies in the over-current overload and short circuit protection of transformers, battery charger, switches, switch power supply, adaptor, meter, instrumentation, apparatus, electronic coils, control panels, air conditioner, automotive electron, etc. Operating Principle of PTC Thermistor for Overload Over-current Protection The operating principle is as indicated in the following. When a circuit is in the normal status, the current through PTC is lower than the rated current and PTC thermistor protector is in the normal state with small resistance value, which will not affect the normal operation of the protected circuit. In case of some fault in the circuit and the current is greater than the rated current, the PTC thermistor protector will become hot quickly and present a high resistance state, which sets the circuit relatively "off" to protect the circuit from damage. After the fault is removed, PTC thermistor protector will automatically restore its low resistance state and the circuit will resume normal operation. Normally, when PTC thermistor is used as an overcurrent protection component, it is preferred to select maximum operating current, maximum operating voltage and proper specifications. Furthermore such factors should be taken into consideration as the dimensions of the components, rated zero-power resistance, operating temperature range, etc.
Thermal Gap Pad, thermal pad, thermal gap filler GLPOLY thermal pad is featuring a high thermal conductivity of 6.0W/mK, its higher than that of most of competitor. Comparing with Bergquist gap pad 5000S35, the data will shows that GLPOLY thermal gap filler pad can perfectly replace the BQ 5000S35. Firstly, the thermal conductivity of GLPOLY thermal gap filler pad is higher that that of BQ 5000S35; the thermal resistance is only 0.16in2/W, its just one third of BQ 5000S35. Comparison data reflects that GLPOLY thermal gap filler pad offers more excellent thermal performance than BQ5000S35. For the electrical property, the dielectric breakdown voltage is 16KV, its 3 times greater than BQ 5000S35s. this will ensure the stability of performance of devices. The material yields extremely soft characteristics while maintaining elasticity and conformability. Conforms to demanding contours and maintains structural integrity with little or no stress applied to fragile components. The inherent natural tack on both sides assists in application and allows the products to effectively fill gaps, reducing thermal resistance and enhancing the overall thermal performance. GLPOLY thermal gap filler pad is ideal for high-performance application at low stress or pressure. Features Ultra conformability Designed for low-stress applications Fiberglass reinforced for puncture, shear and tear resistance ThicknessMm---- 0.3~5.0 Densityg/cm3---- 2.6 ,HardnessShore 00--20,20 Thermal Conductivity W/m*K--2.0,2.8
Pellets Φ1-3mm 99.999% Φ2-4mm
Overview Quick Details Place of Origin: Shanghai, China Brand Name: Longjoin Type: Custom Dimming Max. Load Power: 1.2VA Voltage: 110-277VAC Product name: photo electric light control Application: Street Lighting,Garden Lighting,Landscape Lighting etc Photocell controller Schematic: photodiode sensor Output: 0-10V Dimming / optional Logo: Customized logo,>500 Cover material: PC Power Consumption: 1.2VA On-Off Levels: 50 lux HS CODE: 85365000 We are factroy: Factory in Shanghai city.Best products for you. Supply Ability Supply Ability: 50000 Piece/Pieces per Month Packaging & Delivery Packaging Details Each piece in one small white paper box, 100 boxes in one master carton. Port Shanghai/Ningbo/Any port of China