Description
The Trusted Field Termination Assembly (FTA) 24V dc Digital Input T8800 is designed to act as the main interface between a field device generating a digital signal and the Trusted TMR 24V dc Digital Input Module T8403.
Features
40 input channels per FTA.
Industry standard field device connections (2-wire).
Standard DIN rail compatibility.
Simple installation and connection.
24V dc operation.
SmartSlot connection for one to many hot replacement of input modules.
Fused field power supply per channel.
On-board LED indication field power supply integrity.
Description
The Trusted 40 Channel Analogue Input FTA T8830 is designed to act as the main interface between a field device generating an analogue signal and the Trusted TMR Analogue Input Module T8431.
Features
40 input channels per FTA.
Industry standard field device connections (2-wire).
Standard DIN rail compatibility.
Simple installation and connection.
24V dc operation.
SmartSlot connection for one to many hot replacement of input modules.
Fused field power supply per channel.
On-board LED indication field power supply integrity.
Description
The Trusted 40 Channel Analogue Output or Digital Output FTA is designed to act as the main interface between the Trusted TMR 24V dc Digital Output Module T8451 or Trusted TMR Analogue Output Module T8480 and Trusted the field device. The signal from the output modules are 24V dc and 0-20mA respectively.
Features
40 output channels per FTA.
Industry standard field device connections (2-wire).
Standard DIN rail compatibility.
Screw clamp terminals on both field and power.
Simple installation and connection.
24V dc operation.
SmartSlot connection for one to many hot replacement of output modules.
Field power supply arranged in five groups of eight channels, with OV isolation between groups.
On-board LED indication field power supply integrity.
Field terminal wire size allowance 12 to 28 AWG
Description
The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels.
Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices.
The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module.
Features
40 Triple Modular Redundant (TMR) output channels per module.
Comprehensive, automatic diagnostics and self-test.
Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults.
2500V dc optical isolation barrier.
On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations.
Front panel output status LEDs for each point indicate output status and field wiring faults
Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated)
TUV Certified for non-interfering applicatins
Outputs are powered in isolated groups of eight
Description
The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels.
Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices.
The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module.
Features
40 Triple Modular Redundant (TMR) output channels per module.
Comprehensive, automatic diagnostics and self-test.
Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults.
2500V dc optical isolation barrier.
On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations.
Front panel output status LEDs for each point indicate output status and field wiring faults
Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated)
TUV Certified for non-interfering applicatins
Outputs are powered in isolated groups of eight
88252 Electric Components Suppliers
Short on time? Let Electric Components sellers contact you.