High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
An ECG bulb with an electrode cup is a component used in electrocardiogram (ECG) machines for detecting and recording the electrical activity of the heart. Electrode Cup: The electrode cup is the part of the ECG bulb that makes direct contact with the patient's skin. It is designed to provide a conductive interface for accurately capturing the electrical signals produced by the heart. Material: The electrode cup is usually made of metal or a conductive material that ensures good electrical conductivity and signal transmission. The bulb portion may be made of plastic or silicone, providing flexibility and durability. Compatibility: ECG bulbs with electrode cups are designed to be compatible with specific models of ECG machines. They may come in different sizes and configurations to fit various electrode placements and patient needs. Application: During an ECG procedure, the ECG bulb with an electrode cup is placed on the patient's chest, limbs, or other specific locations as directed by the healthcare provider. The electrode cup makes contact with the skin, allowing the ECG machine to detect and record the electrical activity of the heart. ECG bulbs with electrode cups are essential components of ECG machines, providing a reliable interface for capturing the electrical signals of the heart during diagnostic procedures. Their design, material composition, and compatibility with ECG machines make them valuable tools in cardiovascular healthcare settings.
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
ECG Machine-6
ECG Machine- 12
holter ECG lead cable
ECG 1200G 12-channel ECG is such a kind of electrocardiograph, which gathers 12-lead ECG signals simultaneously and prints out the ECG waveforms with thermal printing systems. Its users are mainly hospitals and all kinds of medical establishments. Main Characteristics: 800x600 dots high resolution color LCD. Convenient and quick button setup. Automatic/manual mode to record and display ECG waveform. Auto-measure of ECG waveform parameter.
3.5 TFT Color LCD Simultaneous 12 Leads display. Auto-analysis and auto-interpretation. Provide more than 10 printing modes. More than 1000 cases in internal memory. Can print 90 minutes and printout 150 pcs ECG continually
ECG 600G Six channel ECG is such a kind of electrocardiograph, Which samples 12 leads ECG signals simultaneously and prints Out the ECG waveforms with thermal printing systems. Its functions are as follows: Recording and displaying ECG waveforms in auto/manual mode; uto-measuring and auto diagnosing the ECG wave parameters; Prompting the sate of lead off and paper lack; Switching several kinds of interface languages; Managing the case database..
DEFIBTECH LIFELINE ECG Package Features The device uses biphasic waveform technology to ensure the greatest possible likelihood of saving a life during a cardiac emergency. The full-color interactive video display provides step-by-step coaching for CPR chest compressions, rescue breathing, and defibrillation. A built-in metronome makes it easy to maintain the optimal rate of chest compressions
Leads:12 Channel Sample Rate:10240Hz Anti-Interference Compatible with Win xp,7,8,10 Support Stress and Resting ECG Testing USB Power Supply
Hotsale Cheap Digital Hospital Electrocardiogram 12 Channel ECG Machine BM-ECG12A Benemed Hotsale Digital Hospital Electrocardiograph 12 Channel ECG Machine Features: It has the function of automatic measure of conventional ECG Parameters (more than 200 cases),which can reduce the burden of doctors. Automatic mode and manual mode are available. Baseline stability test,ensure that each time can be printed out neat and beautiful ECG waveform. The digital isolation technology is used to suppress the drift of ECG signal, AC filter,EMG filter and heart rate detection by the processor to ensure the authenticity and reliability of the output signal. Manual/auto 1, 1+1, 3, 6, 12CH display. Manual/auto working modes. Benemed Hotsale Digital Hospital Electrocardiograph 12 Channel ECG Machine Technical Specification: Sampling rate:1000Hz. Frequency Response:0.05~150Hz(-3dB) Time Constant:3.2s CMRR:>100dB Patient Leakage Current:
High quality conductive ECG gel for both short & long time monitoring. Hypoallergenic Non irritating Odorless Water soluble
1.Dynamic ecg monitor & analysis 2.Dynamic heart rate monitor & analysis 3.Waterproof grade:ipx7 4.Exercise data record 5.Calories burned calculation 6.Examination before exercise 7.Fatigue analysis 8.Sub-health detect 9.Battery:200mah, 8 months normally use, 36 months standby 10.Applicable models:iphone 4s and higher, android 4.3 and higher -
BRAND:GE
Features: 7 inch 480x680 color graphic LCD display Three channel ECG machine with interpretation 12-lead ECG simultaneous acquisition Multiple operation modes: Manual/Auto/Arrhythmia Analysis Modes 80mm 3-channel recording with a rhythm lead Digital filters eliminate EMG, AC, Baseline Drift interference Built in rechargeable Li-Ion battery, 3 hours continuous working Adapt 110-240V, 50/60Hz AC power supply 250 patients save/replay Built in USB/RS232 interface
ECG: 12-lead resting PC-ECG with auto interpretation VCG: Vector-cardiograph with auto interpretation Hardware Features: High sampling rate of 1000Hz Digital filter system Applying anti-baseline-drift technology ensuring the stability of ECG baseline Wilson and Frank hookup system Meet the international standard of IEC60601-1 Easy operation and perfect printout Diagnosis of coronary heart disease Perfect time domain, frequency domain and non-linear HRV analysis Perfect ECG database management system Specification for PC-ECG: Sample rate: 1000Hz, simultaneous 12 leads recording Resolution:12bit Power: 5.0V (DC) Patient Insulation: 4000V AC Defibrillation Protection: Built-in box Digital resolution: 2V Frequency response: 0.05-250 Hz Common mode rejection: >90dB Input impedance: >10MΩ Time constant: 3.2 s Max electrode potential: ±300mV DC Dynamic range: ±10mV Isolate voltage: 4000V Current leak:
12-lead simultaneous standard resting ECG 7-inch TFT, touch screen, led backlight Digital isolation technology and signal processing solution, digital filter Patient management, name and age and id. Detail analysis report. Multi-language options: Germany, France, Italian, Turkey, etc Built-in lithium rechargeable battery, wide thermal printing system USB and LAN socket Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive Auto-measurement, auto-analysis, and auto-interpretation
Pediatric disposable ECG electrode, 40mm, nonwoven cloth,1000pcs per box