Please click here to check who's online and chat with them.

Find Verified Diesel Generators Suppliers, Manufacturers and Wholesalers

Sep-28-22
 
EAC 825
Engine
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Aug-04-22
 
EAC 750
Engine: CUMM NS
Engine Model : QSK19-G11
Stand By kVA: 740
Stand By kW : 592
Prime kVA: 672
Prime kW : 538
Rated Current : 968

Engine
CUMM NS heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
Thermal magnetic CB (for automatic models)
Super Silent Canopy
Mobile Generator Sets
Automatic fuel filling system
Synchronization panel
3 Pole and 4 Pole ATS (Automatic Transfer Switch)
Fuel Heater, Oil Heater
External fuel tank and automatic fuel filling system
Fuel - water separator filter
Remote monitoring and control system

Engine CUMM NS
Engine Model QSK19-G11
Number of Cylinders 6 - Inline
Injection System Direct
Compression Ratio 15.9 : 1
Bore 159
Strok 159
Displacement lt 19
Air Intake Turbo Aftercooler
Speed (RPM) 1500
Oil Capacity lt 80
Standby Power kW / Hp 667 / 907
Prime Power kW / Hp 606 / 827
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity lt 42
Fuel Consumption (lt / h) lt Full Load 135
lt %75 LOAD 103
lt %50 LOAD 69,5

Frequency Hz 50
Power kVA 740
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8

Weight (Silent) Kg 5750
Weight (Open) Kg 4900
Width (Silent) mm 1900
Length (Silent) mm 4800
Height (Silent) mm 2700
Fuel Tank Capacity lt 1350

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jun-23-22
 
EAC 550
Engine: CUMMNS
Engine Model : KTA19-G3A
Stand By kVA: 550
Stand By kW : 440
Prime kVA: 500
Prime kW : 400
Rated Current : 720
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTA19-G3A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.9:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged & Intercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 504 / 675
Prime Power kw / Hp 448 / 600
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 107
L %75 LOAD 82,3
L %50 LOAD 56,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5085
Weight (Open) Kg 4410
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Apr-20-21
Supplier From United States
Apr-14-21
Supplier From Dewas Naka, Madhya Pradesh, India
3015 Diesel Generators Suppliers
Short on time? Let Diesel Generators sellers contact you.
Mar-23-21
Supplier From Chengdu, China
Dec-04-14
Supplier From Shanghai, China
Dec-23-20
Supplier From Umraniye , Istanbul, Turkey
Nov-12-20
Supplier From India
Nov-29-20
Supplier From Cavite, Philippines
Oct-26-20
Supplier From Bharuch, Gujarat, India
Oct-19-20
Supplier From Crewe, United Kingdom
Oct-14-20
Supplier From Kenya
Jun-09-20
Supplier From India
Mar-01-16
Supplier From Dhaka, Bangladesh
Jun-30-20
Supplier From China
Jun-12-20
Supplier From -Alwar, Rajasthan, India
Apr-22-20
Supplier From India
Mar-30-20
Supplier From Hatay, Turkey
3015 Diesel Generators Suppliers
Short on time? Let Diesel Generators sellers contact you.