Please click here to check who's online and chat with them.

Find Verified Diesel Generators Suppliers, Manufacturers and Wholesalers

Jun-21-23

Industrial Hydroxygen Gas Generator

$5.00K - $25.00K
MOQ: Not Specified
 
The Hydrogen Technologies Hydroxygen series (Industrial & Commercial use) is focused around the Proton Exchange Membrane (PEM) electrolysis technology of which Hydrogen Technologies has put their our own style and engineering excellence standards on. The machine produces a mixed atomic count of 66.6% hydrogen and 33.3% oxygen gas by splitting the water molecules of distilled or demineralised water.
Apr-24-22
 
JCBENERGY engine
  JCBENERGY alternator
Soundproof
  50 / 60 HZ
127 / 220V, 230 / 400V, 277 /480V

jcbenergy GENERATOR MANUFACTURER
Jun-21-22

Diesel Generator Set

$6.50K
MOQ: Not Specified
Supplier From Weifang, Shandong, China
 
Power HF Series land use Diesel generator set uses 95 and R series diesel engines of the company, among which R series introduces technology from Ricardo in Britain and forms a complete set with alternators famous at home and abroad such as Stanford and Marathon alternators. The prime power of the set is from 15 to 2000kva.
The generator set powered with R Series Diesel Engine has advantages of sufficient power, low fuel consumption, low emission, low noise, and good starting performance at low temperature.
Over the last 17 years, we have supplied JOHN DEERE, the world's largest agricultural equipment manufacturer, with over 100,000 units diesel engines.
Over the last 17 years, we have supplied JOHN DEERE, the world's largest agricultural equipment manufacturer, with over 100,000 units diesel engines.
Nov-05-22
 
EAP 88
Engine: PERKINS
Engine Model : 1104A-44TG2
Stand By kVA: 88
Stand By kW : 70,4
Prime kVA: 80
Prime kW : 64
Rated Current : 115,2

Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERK�°NS
Engine Model 1104A-44TG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 88 / 120
Prime Power Hp 80 / 110
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 18,5
Lt %75 LOAD 14,2
Lt %50 LOAD 9,8

Frequency Hz
Power kVA 93
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1350
Weight (Open) Kg 1160
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-29-22
 
EAP 70
Engine: PERKINS
Engine Model : 1104A-44TG1
Stand By kVA: 70
Stand By kW : 56
Prime kVA: 64
Prime kW : 51
Rated Current : 92

Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERK�°NS
Engine Model 1104A-44TG1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 65,6 / 88,5
Prime Power Hp 59,6 / 80,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 14,6
Lt %75 LOAD 11
Lt %50 LOAD 8

Frequency Hz
Power kVA 79
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1280
Weight (Open) Kg 1100
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
3019 Diesel Generators Suppliers
Short on time? Let Diesel Generators sellers contact you.
Nov-05-21

Generators

$10.00K
MOQ: Not Specified
 
Since its discovery, the diesel engine has been re-invented and developed vastly to improve on its performance and efficiency, while simultaneously increasing its range of applications. One of its most common uses today is in diesel generators used to provide backup or standby power to facilities and systems in case of power failure. Our diesel generators are designed to monitor electric current continuously, and they automatically start when there is a power interruption and switch off when utility service comes back online.
Tungwell power has been appointed as Original Equipment Manufacturer (OEM) by Cummins, Perkins, MTU, Yanmar, Kubota, Baudouin, etc. Our generators' power range is from 5kva to 3,900kva for a single unit and can be synchronized to form an Independent Power Plant. They come in open type, soundproof type, containerized packages and lighting towers.
Oct-22-22
 
EAP 66
Engine: PERKINS
Engine Model : 1103A-33TG2
Stand By kVA: 66
Stand By kW : 52,8
Prime kVA: 60
Prime kW : 48
Rated Current : 86,4

Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERK�°NS
Engine Model 1103A-33TG2
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 60,5 / 82
Prime Power Hp 55 / 74
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 10,2
Fuel Consumption (lt / h) Lt Full Load 14
Lt %75 LOAD 10,4
Lt %50 LOAD 7,2

Frequency Hz
Power kVA 66
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1200
Weight (Open) Kg 1030
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-17-22
 
EAP 22
Engine: PERKINS
Engine Model : 404A-22G1
Stand By kVA: 22
Stand By kW : 17,6
Prime kVA: 20
Prime kW : 16
Rated Current : 28,8

Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERKINS
Engine Model 404A-22G1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 23.3:1
Bore 84
Strok 100
Displacement Lt 2,21
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 10,6
Standby Power kw / Hp 20,6 / 27,8
Prime Power Hp 18,7 / 25,2
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 14
Fuel Consumption (lt / h) Lt Full Load 5,3
Lt %75 LOAD 4
Lt %50 LOAD 2,9

Frequency Hz
Power kVA 22
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 720
Weight (Open) Kg 590
Width (Silent) Mm 950
Length (Silent) Mm 2000
Height (Silent) Mm 1200
Fuel Tank Capacity Lt 125

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-10-22
 
EAC 1000
Engine: CUMMINS
Engine Model : KTA38-G2A
Stand By kVA: 1000
Stand By kW : 800
Prime kVA: 909
Prime kW : 727
Rated Current : 1308

Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMM�°NS
Engine Model KTA38-G2A
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 895 / 1199
Prime Power Hp 813 / 1089
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 202,3
Lt %75 LOAD 153,7
Lt %50 LOAD 103,1

Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9350
Weight (Open) Kg 8200
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-07-22
 
EAC 890
Engine: CUMMINS
Engine Model : KTA38-G2B
Stand By kVA: 890
Stand By kW : 712
Prime kVA: 809
Prime kW : 647
Rated Current : 1165

Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMM�°NS
Engine Model KTA38-G2B
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 789 / 1057
Prime Power Hp 711 / 953
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 176,9
Lt %75 LOAD 133,3
Lt %50 LOAD 91,3

Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9300
Weight (Open) Kg 8150
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Mar-30-21
 
Place of Origin - Turkey and Germany
Brand Name - LOTUS
Model Number - LOTUS-GEN LOTUS-GAS
Usage - SVC
Phase - Three Phase
Protection - IP20 / IP55 / IP65
Frequency - 50Hz/60Hz
Power factor - 0.8/0.9/1/Customized
Color - Black or RAL7035 or Customized
Rated power - 10KVA - 4000KVA
Sep-27-22
 
EAC 825
Engine: CUMM�°NS
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Feb-05-22

Cat Generator Available

$800.00K
MOQ: Not Specified
 
CAT Generator available
Price: USD800000 per unit
Quantity: 5 units available
Model: 2012
After sale continue to jebel ali
Jun-09-22
 
Our main products cover diesel generators of
is a series of diesel engines with the technology of , which one is the expert in manufacturing of marine diesel engine
Aug-03-22
Supplier From United States, United States
 
Eight (8) 1825 KVA Caterpillar 3516 Diesel Generator sets in Sound Proof Containers, Year 2010, 21,000 to 22,000 hours, 1500 rpm, 400 volt, 3 Phase, 50 HZ, Caterpillar serviced and maintained. Good running units.
Aug-03-22
Supplier From United States, United States
 
2000 KVA Yanmar Diesel Generator open skid mounted, Engine Model 16H-NHL ETP, Leroy Somer Alternator, 1500 rpm, 400 volt, Year 1991, 50 HZ, P.F. 0.08, 3 Phase, only 77 hours since run time, Good Condition
Aug-03-22
Supplier From United States, United States
 
Deutz TBD 620 V16 Diesel Generator. 2000 KVA in Sound Attenuated Container, Stamford Alternator, 1500 rpm, 400 volt, Year 2001, 50 HZ, P.F. 0.08, 3 Phase, 1000 hours since engine overhaul. Good Condition
Aug-03-22
Supplier From United States, United States
 
1125 KVA Mitsubishi S12 Diesel Generator Set
1125 KVA/900 KW Mitsubishi S12 NPTK2 Open Skid Mounted Diesel Generator Set, 400 Volt, 50 HZ, 3 Phase, PF 0.08, 4 wire, Year 1990, 7446 hours, Alternator, Radiator, panels, ABB breaker panel, silencers, Good running set
Aug-03-22
Supplier From United States, United States
 
Cummins KTA50 Genset
1500 KVA Cummins KTA50 G4 Diesel Generator, 40 FT Tri axle Trailer Mounted Portable Sound Enclosed Diesel Generator, 400 Volt, 50 HZ, 3 Phase, PF 0.08, 4 wire, Year 1991, 0 hours since overhaul, Radiator, panels, synchronization panels, breaker panel, silencers, Good running set
Aug-03-22
Supplier From United States, United States
 
This is a used system that we took off a diesel generator and it runs perfect. It handles up to 2500 KW Diesel Generator Set. The system did everything it was supposed to do and will save money on fuel and maintenance.
This is an Easy bolt-on environmental and cost saving solution. There is No engine modifications needed. It operates on gas percentages up to 75%. Use it with Pipeline Gas, Liquid Gas, Compressed Gas, Natural Gas, Wellhead Gas, Bio-Gas, Coal-Based Gas and Propane Fuel.
There is No loss of: Power Output, Engine Performance, Efficiency, Stability and Load Acceptance. It provides longer duration between maintenance and replacement parts.
3019 Diesel Generators Suppliers
Short on time? Let Diesel Generators sellers contact you.