Audited Supplier and Direct Seller: **Please note we are not agents, intermediaries,brokers or Dropshipping** 1. 3PLY MOQ: 5000 boxes 2. Medical Masks MOQ: 5000 boxes 3. N95 MOQ; 5000 boxes 4. Thermometer MOQ: 5000 5. Protective Suits/Gowns Sterile. MOQ: 5000 pieces **Details** ��CE marking and TUV certified; ��EU confirmity; ��FDA approved for 1. 3PLY and 2. Medical masks. ��DHL door to door delivery based on zipcode. ��50% Dep TT and 50% TT after Airway bill number. --- 3PLY Civil use masks, carton is 52*38*30cm 2400pcs/carton, 50 pcs in one box, 40 boxes in one carton ;weight 13kg --- Medical use masks, one box 50 pcs, one carton 1200 pcs --- Contact : +60 162601434
TEST KIT FOR THE SARS-COV-2 ALSO KNOW AS THE NOVEL CORONA VIRUS 2019 (NCOV-19).
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Gentamicin in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Gentamicin in the sample and pre-coated coupling antigen on the micro-well stripes compete for the anti-Gentamicin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Gentamicin in it. The value is compared to the standard curve and the Gentamicin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.05 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1 Principle This test kit is based on the competitive enzyme immunoassay for the detection of Fluoroquinolones in the pork, chicken, fish and shrimp, etc. The Fluoroquinolones in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Fluoroquinolones antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration.The optical density (OD) value of the sample has a negative correlation with the Fluoroquinolones in the sample. This value is compared to the standard curve and the Fluoroquinolones concentration is subsequently obtained. 2 Technical specifications Sensitivity: 0.1 ppb Incubation Temperature: 25 Incubation Time: 30min15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in samples. The coupling antigens are pre-coated on the micro-well stripes. The Florfenicol in the sample and the conjugate antigens pre-coated on the micro-well stripes compete for the anti-Florfenicol antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value has a negative correlation with the Florfenicol concentration in the sample. This value is compared to the standard curve and the Florfenicol concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.1 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Tylosin in the sample. The coupling antigens are pre-coated on the micro-well stripes. The Tylosin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Tylosin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Tylosin in it. This value is compared to the standard curve and the Tylosin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.5 ppb Incubator temperature: 25 Incubator time: 75 min
ROC-F-OR003K Melamine ELISA Test Kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Melamine in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Melamine in the sample and the coupling antigens pre-coated on the micro-well stripes compete for anti-Melamine antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the Melamine concentration in the sample. This value is compared to the standard curve and the Melamine concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.5 ppb Incubator temperature: 25 Incubator time: 30minï½?15min Detection limit: Milk powder 10 ppb Milk 1 ppb Feed 50 ppb Cross-reaction rate: Melamine 100% Cyanuric acid 60% Triazine
Malaria Antigen Pf/Pv test
K3 EDTA tubes for blood collection
HCG Strip test
Diagnostic kits PREGNANCY TEST hCG Card test
Vocom (88890300) is the latest volvo interface for diagnosis & communication with vehicles, including the new euro 6 vehicles range. It can work with the volvo 1998 and older trucks, version2 2002 and newer. It replaces all previous models 88890020 and 88890180. Please noted that the price doesn¡¡£¤t include the activation and update. If activation or update to vtt2.02 needed, charge usd300 for one time. Packing list: 88890300 vocom interface 88890304 obd2 cable 88890306 8-pin cable for european trucks 88890305 usb cable Vtt 2.01 software cd (activation not included)
Bi-level positive airway pressure non-invasive ventilator equipment Auto-leak compensation Auto-altitude compensation Alarm for cut down the power Independent airflow channel Huge display, 2.8¡¡à tft screen, show airflow and pressure on screen Parameters lock: all the parame hanged after setting Dimensions: 180l x 118w x 96h mm
Sleep fairy equipment Storage data: over 80 hours data Communication: usb 2.0 Spo2: 40% - 100% Pulse rate: 20 ¡§c 240 bpm Battery rechargeable lithium battery: 1700mah Continuous recording time: over 30 hours Screen: 2.8 inch tft Features Compact, light and convenient; Extremely easy to operate with one switch; Huge display, 2.8¡¡à tft screen, showing all channels, include the ambient temperature and recording time; Reliably providing extensive, detailed and accurate sleep clinical data; Suitable for home sleep testing and ambulatory use; Sophisticated scoring and diagnostic report software; Link to any cpap device to titrate patient¡¡¥s pressure; Dimensions: 75mml x 125mmw x 24mmh Weight: 200g with battery
Specification Dimensions: 75mml x 125mmw x 24mmh Weight: 200g with battery 9 channels: air flow, snore, spo2, pulse rate, body position, body movement, respiratory effort, cpap pressure, ambient Spo2: 40% - 100% Pulse rate: 20 ¡¡ìc 240 bpm Battery rechargeable lithium battery: 1700mah Continuous recording time: over 30 hours Screen: 2.8 inch tft Features Reliably providing extensive, detailed and accurate sleep clinical data; Suitable for home sleep testing and ambulatory use; Sophisticated scoring and diagnostic report software; Link to any cpap device to titrate patient¡¡£¤s pressure; Dimensions: 75mml x 125mmw x 24mmh Weight: 200g with battery
Continuous positive airway pressure non-invasive ventilator equipment Suitable for osa patients (obstructive sleep apnea patients). Specification Pressure range:4-20cmh2oh Work mode:Cpap, auto, bipap Ramp item:0-60min adjustable 1min/step Dimensions:180l x 118w x 96h mm Dc voltage:24vdc Dc current:2.5a maximum Lcd screen:2.8 inch, 320 x 240 Protection against electric shock:Class ii, type bf Data communicationUsb 2.0 Features: Auto-adjusting pressure for personalized treatment during sleep; More than 20hr real time data and more than 1 year used records can be saved; Showing airflow and pressure waves on screen; Usb port for data communication; Combined smart technologies; Contemporary and stylish design for bedroom appeal. Epr(expiratory pressure relief) Auto-leak compensation Auto-altitude compensation Alarm for cut down the power Independent airflow channel Huge display, 2.8¡¡à tft screen, show airflow and pressure on screen Parameters lock: all the parameters can¡¡¥t be changed after setting Dimensions:180l x 118w x 96h mm
Auto continuous positive airway pressure non-invasive ventilator equipment Suitable for osa patients (obstructive sleep apnea patients). Specification Pressure range:4-20cmh2oh Lcd screen:2.8 inch, 320 x 240 Protection against electric shock:Class ii, type bf Data communicationUsb 2.0 Features: Auto-adjusting pressure for personalized treatment during sleep; More than 20hr real time data and more than 1 year used records can be saved; Showing airflow and pressure waves on screen; Usb port for data communication; Combined smart technologies; Contemporary and stylish design for bedroom appeal. Epr(expiratory pressure relief) Auto-leak compensation Auto-altitude compensation Alarm for cut down the power Independent airflow channel Huge display, 2.8¡¡à tft screen, show airflow and pressure on screen Parameters lock: all the parameters can¡¡¥t be changed after setting Dimensions:180l x 118w x 96h mm
Applicable instruments mainly include abi prism 7300, abi prism 7500, abi prism 7700, abi prism 7900, da-7600, line gene, and icycler etc. 48 tests/kit, large package.
7mhz(matching 6.5mhz cavity probe and 7 mhz high-frequency linear array probe). .Calculation: distance, perimeter, area, heart rate, pregnancy week (bpd, gs, crl, fl, ac) and anticipated delivery date. .Note: name, serial numbers of case history, gender, age, 16 body marks (with probe), full-screen character, real-time clock .Puncture guide: the puncture guide line can be displayed under b mode. .Gain control: the total gain, near field and far field can be adjusted successively. .Image polarity: left/right, black/white and up/down reverse. .Fractionated gain: 2 time of enlargements .Movie memory: 256 pictures can be memorized successively when the real-time is displayed. .Image memory: 128 pictures permanent storage. .Image review: images can be reviewed successively and checked one by one. .Output interface: 2 groups of svga video output may mate with svga color monitor.And 2 groups of pal video output may mate with pal monitor, video image recording instrument and image workshop, etc. 1 group of usb connection
Ps2 is a high-tech and professional automobile diagnostic tool. Please follow the instruction to use the product. If you have any problems or questions related to the operation, please contact post-sale technical service department for further instruction. Ps2 test trucks: Cummins, isuzu, mack, volvo, man, scania, Mercedes-benz, hino, iveco and daf 1)man - the program, a wire, how many 16 pin Packing:in carton Weight: 10kg