Intended Use
Malaria pf (HRP II) / pv (LDH) Antigen Test is for the rapid qualitative determination of Malaria P. falciparum specific histidine rich protein-2 (Pf HRP-2) and Malaria P. vivax specific lactate dehydrogenase (pvLDH) in human blood as an aid in the diagnosis of Malaria infection.
Contents of Kit
Malaria pf/pv Antigen Test Card 25 ea
Malaria Sample Buffer 1 ea
Instructions For Use 1 ea
Storage And Stability
The kit can be stored at room temperature or refrigerated (4-30ípC). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.
Pre Cautions
1. For professional in vitro diagnostic use only. Do not use after expiration date.
2. Do not eat, drink or smoke in the area where the specimens or kits are handled.
3. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens.
4. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are being tested.
5. Humidity and temperature can adversely affect results.
All of our products are ce, fda and iso 13485 certificated with competitive price (negotiable) and warranty in international market. Meanwhile, excellent services and prompt delivery help us win great fame among customers.
1. Convenient, reliable results, capillary action strips allow a quick and simple application of blood. In only 20 seconds, the meter produces an accurate reading.
2. Less painful results, requires only 3ul of blood and allows testing on forearm and palm.
3. Affordable results. Frequent testing helps improve control.
4. Information to better manage diabetes. Memory feature stores up to 30 tests and provides 7, 14 and 30-day averaging.
One kit of glucose testing system includes all the following
Biocare blood glucose meter
10 test strips (free)
One adjustable lancet device
10 sterile lancets (free)
Ownerí»s booklet
One carrying case
Two 3.0v lithium batteries (installed)
Specifications
Measuring range: 2.2-27.8mml/l (40-500mg/dl)
Measuring time: 20 seconds
Memory capacitance: 30
Power source: two replaceable 3-volt batteries (cr2032)
Batteries life: > 1000 tests
Life of test strips: 12 months (vial sealed), 3 months (after vial opened)
Volume of blood: 3ul
Net weight: 52g
Dimensions: 97(l)*55(w)*15(h) mm
Item: glucose meter and testing strip
Model no.: sg-1
Description: 97(l)*55(w)*15(h) mm
Package: color box
Moq: 500pcs for meters , 1000bottles for strips(50strips/bottle)
Ctn size: 72*58*54cm , 35*22*51.5cm
Q'ty/20': 2100pcs; q'ty/40': 4200pcs
Loading port: shanghai
Payment terms: t/t in advance, l/c, etc.
Valid time: 60 days
All of our products are ce, fda and iso 13485 certificated with competitive price (negotiable) and warranty in international market. Meanwhile, excellent services and prompt delivery help us win great fame among customers.
1. Convenient, reliable results, capillary action strips allow a quick and simple application of blood. In only 20 seconds, the meter produces an accurate reading.
2. Less painful results, requires only 3ul of blood and allows testing on forearm and palm.
3. Affordable results. Frequent testing helps improve control.
4. Information to better manage diabetes. Memory feature stores up to 30 tests and provides 7, 14 and 30-day averaging.
One kit of glucose testing system includes all the following
Biocare blood glucose meter
10 test strips (free)
One adjustable lancet device
10 sterile lancets (free)
Ownerí»s booklet
One carrying case
Two 3.0v lithium batteries (installed)
Specifications
Measuring range: 2.2-27.8mml/l (40-500mg/dl)
Measuring time: 20 seconds
Memory capacitance: 30
Power source: two replaceable 3-volt batteries (cr2032)
Batteries life: > 1000 tests
Life of test strips: 12 months (vial sealed), 3 months (after vial opened)
Volume of blood: 3ul
Net weight: 52g
Dimensions: 97(l)*55(w)*15(h) mm
Item: glucose meter and testing strip
Model no.: sg-1
Description: 97(l)*55(w)*15(h) mm
Package: color box
Moq: 500pcs for meters , 1000bottles for strips(50strips/bottle)
Ctn size: 72*58*54cm , 35*22*51.5cm
Q'ty/20': 2100pcs; q'ty/40': 4200pcs
Loading port: shanghai
Payment terms: t/t in advance, l/c, etc.
Valid time: 60 days
Our Diatermo 160, by selecting the modes of operation, provides cut pure cut, coagulated cut, forced coagulation, soft coagulation and û with forceps û bipolar coagulation. It is particularly suitable for very damp operational fields such gynaecological and orthopaedic surgery. The Leading-Edge Technology enables highly professional surgery intervention; Open Circuit (OC) Alarm warns the user that connection into the neutral plate has not been made or that the cable is disconnected or the neutral plate is not in contact with the patient; in this case HF emission for cut and coagulation operation is switched off. Gima offers a wide family of Diatermo and accessories. Models 106 and 108 are monopolar units (50/80 W) suitable for small operations are ideal for veterinary, dentistry, first aid and dermatology work.
All the other Gima mono-bipolar models (120/160/200/250/380/400 W) cover all the operational fields, from middle electrosurgery to surgery where high precision and reliability are essential, as endoscopy surgery.
The available accessories are monopolar forceps, scissors and cables, high quality insulated bipolar forceps and cables, autoclavable electrodes, single use sterile electrodes, single use, metal and rubber plates, monopolar handles (with or without switches), footswitches and board.
Our test strips can be used with the one touch, ultra blood glucose meters. They are simple in operation , convenient and quick in using without any testing equipment. Our products are superior in quality. We also can supply with oem. í¦customerí»s satisfaction is our greatest successí¦ is our principle.
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of chloramphenicol in the tissue (chicken, pork), honey, milk, fish, shrimp and egg. The coupling antigen is pre-coated on the micro-well stripes. The chloramphenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against chloramphenicol. After the addition of the enzyme conjugate, the tmb substrate is added for coloration. The optical density (od) value of the testing sample has a negative correlation with the content of chloramphenicol in it. This value is compared to the standard curve and the content of the corresponding chloramphenicol is subsequently obtained.
4a rapid direct binding- screening test for the presence of antibodies of aids hiv 1 and hiv 2 virus.
Easy to read: tri- line design. Two test lines indicate hiv 1 and hiv 2 infection respectively.
Convenient to use: only use 1 drop of blood.
Considerate design for home pack, include all necessary attachments.
Quick result: read result at 10-15 minutes.
Private: whole blood type are designed for home use.
Blank packs are available.
The malaria p.F/p.V test is a immunochromatographic (rapid) test for the qualitative detection of antibodies of all isotypes (igg, igm, iga) specific to plasmodium falciparum and plasmodium vivax simultaneously in human whole blood.
Product name: malaria pf&pv rapid test
Packing: 25 cassette/box
Specimen: serum/plasma, whole blood.
Min.Quantity 5000 cassettes
Feature: can be used at home for self test or used in hospital, high sensitivity, accurate, easy to use.
Our company---core technology co., ltd. Has our own factory in beijing. And we specializes in r&d, manufacturing, distribution and technical service of the medical diagnostic products. We have competitive price for you.
Description model no. Specification specimen sensivity packing carton dimension weight muni qty
(pcs)
Hbsagone step ultra hepatitis b surface antigen test b11-11 3.0mm strip serum/plasma 5ng/ml 50t/box, 5000t/ctn 60*43.5*30cm 13.5kg 5000
Hbsagone step ultra hepatitis b surface antigen test b11-20 cassette serum/plasma 5ng/ml 25t/box, 1500t/ctn 62*41*37cm 12.5kg 5000
Hbsagone step ultra hepatitis b surface antigen test b11-21 cassette whole blood.