1. Wisetest Salvia Home 1-test- and 5-test-kit FDA 2. iHealth 2-tests-kit EUA 3. Flowflex 1-test-kit EUA Location: OTG US/Spain Location China: 1-2 days production and air ship worldwide Payment: Full TT or LC at sight
RAPID ANTIBODY/Finger Prick 10 to 15 Minute Results An antibody test is also known as a serology test looks for the presence of antibodies, which are specific proteins made in response to infections. It is effective at detecting the recent past SARS-CoV2 infection. This test can detect the body's IgM Antibody response in as little as 7 days (IgG in 14 days) from infection with CDC validated 100% specificity and 100% sensitivity. The highest accuracy serological test on the market FDA EUA Approved Manufactured by one of the leaders in lateral flow technology Results in 10-15 minutes FINGER PRICK NO LAB RESULTS REQUIRED
COVID finger prick, rapid antigen test, or rapid test, is a rapid diagnostic test suitable for point-of-care testing that directly detects the presence or absence of an antigen. It is commonly used for the detection of SARS-CoV-2, the virus that causes COVID-19. Rapid tests are a type of lateral flow tests that detect protein, distinguishing it from other medical tests that detect antibodies or nucleic acid, of either laboratory or point-of-care types. Rapid tests generally give a result in 1 to 15 minutes, require minimal training or infrastructure, and have significant cost advantages. NO Lab Required for results.
COVID-19 Test Kits
Boson EUA slef testing covid antigen test card, DDP Chicago airport/DDP New York airport. Any interest pls contact us!
Simens EUA self testing Antigen nasal swab test & Flowflex EUA self testing Antigen nasal swab test are availble. DDP USA. Any interest pls contact us
This kit is used to qualitatively detect in vitro suspected cases of pneumonitis infected by a new type of coronavirus. The PCR reaction solution contains 2 sets of specific primers and fluorescent probes for specific detection of targets, and an additional set of specific primers and fluorescent probes is used as the internal standard control of the kit for detecting endogenous housekeeping genes. Lowest detection line:200copy/mL Specificity: this kit has no cross-reaction with hepatitis B virus, hepatitis C virus, staphylococcus aureus, gram-positive bacteria, shigella bacillus, influenza A, influenza B, enterovirus and human genome DNA/RNA. Precision reference products: After repeated 20 times, the amplified Ct CV of each fluorescence channel was no more than 5%.Ct CV 5%
This is our new product, it is non cold chain transport , it more convenient for transportation and it will be reduce shipping costs. Product performance index 1.Lowest detection line:200 copies/mL Compliance rate of negative reference: 10 negative references were tested, and the test results were all negative; 2.Specificity: this kit has no cross-reaction with hepatitis B virus, hepatitis C virus, staphylococcus aureus, gram-positive bacteria, shigella bacillus, influenza A, influenza B, enterovirus and human genome DNA/RNA. 3.Precision reference products: After repeated 20 times, the amplified Ct CV of each fluorescence channel was no more than 5%.Ct CV 5%
This kit is intended for qualiativein vitro detection of Orf1ab and N genes of Novel Coronavirus 2019-nCoV which are found in throat swab,sputum and alveolar lavage fuid samples of suspected cases of pneumonia,suspected cases of clustering and other patients who need to carry out diagnosis or differential diagnosis of Novel Coronavirus 2019-nCoV infection.
The disposable virus sampling tube/Virus Transport Medium(VTM) is suitable for nucleic acid extraction of SARS-CoV-2 virus, various influenza viruses, avian influenza viruses, rubella, swine fever and other virus samples. The disposable virus sampling tube/Virus Transport Medium(VTM) is suitable for nucleic acid extraction of SARS-CoV-2 virus, various influenza viruses, avian influenza viruses, rubella, swine fever and other virus samples. It is also suitable for the collection and transportation of specimens of Chlamydia, Mycoplasma, and Mycoplasma Arthroplasma. Samples are usually collected from the mouth, throat, nasal cavity, and anus. Sampling tube: The tube body and tube cover are made of polypropylene, which will not deform at high temperature and high pressure (121C, 15min), and will not become brittle at low temperature (196C). Resistant to static extrusion and dynamic impact. The bottom tapered design is resistant to centrifugation and vibration. Built-in sample preservation solution is used for sample preservation to prevent leakage. Sample preservation solution: Functioned with virus lysis solution and virus nucleic acid preservation solution. The virus lysate realizes the inactivation of the virus in the sample and reduces the risk of secondary infection. The unique protection system can prevent nucleic acid from being degraded and improve the accuracy of downstream detection. The sample has a wide adaptability and can be used for the collection, preservation and transportation of various swabs. Sampling swabs: sampling swabs are flocking sampling heads, which are non-toxic to cells and viruses, and do not contain RNase, which can greatly increase the collection and release of virus samples , ensure the accuracy of PCR detection results. The plastic rod is made of ABS, with a unique molded breaking point design, and there is no tiny debris during the breaking process. Features: 1.More collection and release:nylon flocked swabs provide optimum specimen collection because of their ability to collect more specimen at the collection site and to more rapidly release the entire samples specime 2. High safety factor: it can lyse pathogens, inactivate viruses, and reduce the risk of secondary infection. 3. Stable nucleic acid: a unique protection system that can prevent nucleic acid from being degraded and improve the accuracy of downstream detection. 4. Wide sample adaptability: it can be used for the collection, preservation and transportation of various swabs,Including oral swabs, throat swabs, nasal swabs, vaginal swabs and so on.
We supply all things PPE: Covid Antigen & Antibody Test Kits: Nasal swab, oral swab and finger stick tests; Nitrile Gloves, Vgloves, Top Gloves; Face Shields; 3-ply masks; reusable masks; Gowns, shoe and head covers; thermometers, hand sanitizer.� Also, we are able to supply Covid supply VENDING MACHINES, disinfectant sprays and wipes; disinfectant fogger machines and sprayers.� We currently supply US distributors and medical supply companies coast-to-coast. (Top Quality/Extreme Wholesale). Contact us with your immediate requirement. Tell us what you want, bring us your target price. Satisfaction GUARANTEED! We look forward to working with you. We move a lot of quality products fast, so contact us IMMEDIATELY and join our team!!
Access Bio CareStart rapid antigen POC test kits - We are now shipping (within the US) by the pallet at as low as $10.00 per test. 20 pcs per kit/box, 640 boxes per pallet.
We can supply the following Covid-19 Rapid Antigen Test Kits: Sienna-Clarity, Indicaid, Celltrion Diatrust, InBios Detect, GenBody, QuickVue (Home Test), Binax Now (Home Test). Pricing as low as $6.00 per unit but ultimately depends on the brand and how many units/boxes you require. Please reach out with any inquiries.
Celltrion Diatrust covid-19 Ag rapid tests We have the ability to supply both POC as well as OTC kits. POC kits start at $4.25 per test. OTC kits start at $6.75 per test. All Test Kits are OTG in the US at the Celltrion Warehouse. Delivery is available for a minimal fee, or no fee at all depending on the order. The Test Kits are either picked up at the Celltrion warehouse in TN or NJ or drop shipped to your facility. For large Bulk orders with weekly or monthly allocation, a 10% deposit is required to reserve the specific allocation, and the balance is paid prior to pickup or delivery. Both the POC and OTC Test Kits are available for delivery also in large quantities, however due to the high demand, a pick up schedule or delivery schedule will be determined at the moment the PO is issued and will become an integral part of the supply agreement.
Clinitest OTC covid test kits (by Siemens) - FDA approved for use in the USA - Capacity to supply 5M per week - 50% payment up front, then the remaining 50% after the airway bill and packing slip are provided
- Abbott Nasal POC - Abbott Nasopharyngeal POC - Genrui POC - VivaDiag Saliva POC - FaStep Saliva POC
We have FDA approved Antigen Home test kits with CE and more certifications. FOB China will be from $4 USD/test. Can supply up to 1 million every fortnight, Quantities can be extended. For real buyers, we must arrange a personal meeting in USA, China, New Zealand, Australia and Europe with our local offices.
We have FDA approved Antigen Home test kits with CE and more certifications. FOB China will be from $4 USD/test. Can supply up to 1 million every fortnight, Quantities can be extended. For real buyers, we must arrange a personal meeting in USA, China, New Zealand, Australia and Europe with our local offices.
[Intended Usage] This kit is used for the in vitro qualitative detection of suspected cases of pneumonia caused by New Coronavirus infection, patients with suspected clusters, other patients who need to be diagnosed or differentially diagnosed with the New Coronavirus infection, and nasopharyngeal swabs, oropharyngeal swabs, and bronchoalveolar lavage fluid samples of patients with mutation beads for the New Coronavirus ORF1ab and N gene, S gene N501Y mutation and S gene E484K mutation sites. [Storage Conditions & Validity] 1. The kit should be stored frozen at -20 and protected from light; the expiration date is 6 months; the production date and expiration date are shown in the outer packaging box. 2. Avoid repeated freezing and thawing of the kit and the number of freezing and thawing shall not exceed 7 times. 3. After opening, the bottles should be stored at -20 and protected from light. The number of bottles opening times should not exceed 7 times, which will not affect the use within the validity period. [Applicable Instruments] 1. This kit has been validated on ABI7500 quantitative fluorescence PCR instrument. 2. For other models not listed, relevant experiments have not been performed or completed for this kit. If users need to use this type of instrument platform to carry out the detection of this reagent, please contact our Technical Department at for relevant support. NB: The other devices can include quantitative fluorescence PCR platforms with FAM, VIC, ROX and Cy5 channels. [Sample Requirements] 1. Nasopharyngeal swabs, oropharyngeal swabs and other methods are used to obtain samples, and it is recommended to use commercial virus sampling kits for sample collection devices. [Test Results Interpretation] 1. Negative and positive controls should be tested in each experiment and the test result can be determined only when the controls meet the quality control requirements. 2. When FAM, VIC and ROX channels are positive, Cy5 channel result may be negative due to the system competition. 3. When the internal standard result is negative, if the FAM, VIC and ROX signals of the test sample are also negative, the test result of the sample is invalid, and the cause should be found and eliminated, and the experiment repeated for this sample. [Product Performance Index] 1. Precision: The coefficient of variation Intra-batch / Inter-batch, Intra-day / Inter-day among different operators shall not be higher than 5.0%. 2. Coincidence rate of negative positive controls: The coincidence rate of positive controls and negative controls is 100%. 3. Minimum detection limit: The minimum detection limit of this kit is 500 copies/mL. [CE Mark Registration No.]: RPS/499/2021. [EC REP.]: CMC MEDICAL DEVICES & DRUGS S.L. C/ Horacio Lengo n18, C.P 29006, Milaga, Spain.
INTENDED USE For qualitative detection and differentiation of IgM and IgG antibodies to SARS-CoV-2 in serum, plasma (EDTA, sodium citrate and lithium heparin) or fingerstick whole blood, venous whole blood specimens from patients suspected of COVID-19 infection. FEATURES Coated with carefully selected specific Nucleocapsid and Spike protein antigen. Detection for IgM and IgG antibodies simultaneously. Simple operation, easy result interpreted. Rapid test within 15 minutes. RESULTS INTERPRETATION Positive: 1. The presence of 3 red lines (T1, T2 and C) within the reaction window, no matter which band appears first, indicates presence of both SARS-CoV-2 IgM and IgG antibodies. 2. The presence of 2 red lines (T1 and C) within the reaction window, no matter which band appears first, indicates presence of SARS-CoV-2 IgM antibody. 3. The presence of 2 red lines (T2 and C) within the reaction window, no matter which band appears first, indicates presence of SARS-CoV-2 IgG antibody. Negative: 1. The presence of line (control line) only within the reaction window indicates that no SARS-CoV-2 antibodies are detected. The results is negative. Invalid: 1. If the control(C) line is not displayed in 10-15 min, regardless of whether T1 and/or T2 line is present, the test result is invalid. It is recommended that the specimen should be re-tested. 2. The test result is invalid after 15 min. CLINICAL PERFORMANCE - Positive Percent Agreement (PPA) = 91.07% (153/168) (95% CI: 85.70%-94.92%). - Negative Percent Agreement (NPA) = 95.37% (103/108) (95% CI: 89.53%-98.48%). - Overall Rates of Agreement (ORA) = 92.75% [(153+103)/ (168+108)] (95% CI: 89.03%-95.52%). [Product Name]: SARS-CoV-2 IgM/IgG Duo Test [Product Code]: Cat# FP-319 [Sample Type]: Whole blood /Plasma/Serum [Sample Volume]: 20L /10L/10L [Detection Method]: Colloidal Gold [Reaction Time]: 10-15min [Packing Size]: 1T x 20 cassettes per box + Sample diluent 1 vial x 5mL. [Storage Condition]: 2oC ~ 30oC [Shelf Life]: 12 months [CE Mark Registration No.]: RPS/499/2021.