This kit is using detecting canine parvovirus antigen in canine feces, rectum, vomitus, or saliva. It can be used for screening canine parvovirus infection ,auxiliary diagnosis and so on. Test time:5-10min
The kit uses colloidal gold immunochromatography assay (GICA) to detected antibodies against Brucella in cattle, sheep and goats. The test duration is 10-15 minutes. 20tests/kit
The kit employs colloidal gold immunochromatography assay (GICA) and is specifically designed for the detection of NDV antigens in avian tracheal and cloacal secretions. It is suitable for screening NDV infections and can also be used as an adjunctive diagnostic tool. The test duration is 10-15 minutes.
Specifacation: 1test/box, 5tests/box Storage temperature: 4-30C. No cold-chain Designed for qualitative detection of COVID-19 and Influenza A+B antigen test in Nasal Swab TGA has approved for self test ARTG is: 404883 ISO 13485 and ISO9001 Quality System Production Easy to operate, fast to get result within 15 minutes
Everything needed to run a test with materials provided in each kit: 20 Rapid SARS-CoV-2 Antigen Test Cards (Individually packaged) 2 Sample Buffer 20 Sterilized swabs (Individually packaged) 20 Extraction tubes (Individually packaged) 1 Instruction for use 1 Tube rack (for 6 tubes/rack) Product Information: Quantity: 20 tests/kit Sample type: Nasopharyngeal swab Storage temperature: 2-30 C Shelf life: 18 months Test time: 15-20 minutes Intended Use: This product is authorized and intended for use by trained laboratory or healthcare professionals for in vitro diagnostic use. Point-of-care professionals administering tests are required to report all results to the appropriate public health authorities. Note: Consult your provincial and local health care authorities for POC guidelines for rapid testing use.
Model:FCY-ATG01-SA SARS-CoV-2 Antigen Test kit Saliva Rapid test by Mouth: 15minutes Certificates: CE, ISO13485
Cheap Drug Metabolites Rapid Test Accu-Tell® Multi-line Drug Cassette (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in urine at the cut-off concentrations. TEST PROCEDURE of Saliva Rapid Test Cassette Allow the test, urine specimen, and/or controls to reach room temperature (15-30 ºC) prior to testing. 1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour. 2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120 �¼L) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below. 3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.  LIMITATIONS 1. ACCU-TELL ®  Multi-line Drug Cassette (Urine) provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. 2. There is a possibility that technical or procedural errors, as well as interfering substances in the urine specimen may cause erroneous results. 3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen. 4. A positive result does not indicate level or intoxication, administration route or concentration in urine. 5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test. 6. This test does not distinguish between drugs of abuse and certain medications. 7. A positive test result may be obtained from certain foods or food supplements.  We are Saliva Test Manufacturer. Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.
Alcohol Urine Rapid Test Strip Accu-Tell® Alcohol Rapid Test Strip (Urine) is intended for use as a rapid method to detect the presence of alcohol in urine greater than 0.04%(40mg/dL). To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used. CATALOG Product Name Specimen Catalog No. Quantity per box Alcohol Strip Urine ABT-ACH-A188 100T/50T KEY POINTS Detection for:  Ehyl alcohol in human urine greater than 0.04%(40mg/dL); Reading time:  3 minutes; Relative Sensitivity:  96%; Relative Specificity:  100%; Agreement:  98%.  INTRODUCTION of Hot Sale Urine Rapid Test Strip Alcohol intoxication can lead to loss of alertness, coma, death and as well as birth defects. The BAC at which a person becomes impaired is variable. The United States Department of Transportation (DOT) has established a BAC of 0.02%(20mg/dL) as the cut-off level at which an individual is considered positive for the presence of alcohol. Determination of ethyl alcohol in urine, blood and saliva is commonly used for measuring legal impairment, alcohol poisoning, etc. Gas chromatography techniques and enzymatic methods are commercially available for the determination of ethyl alcohol in human fluids. ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is designed to detect ethyl alcohol in urine specimens.  INTENDED USE ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is intended for use as a rapid method to detect the presence of alcohol in urine greater than 0.04%(40mg/dL). The ACCU-TELL ®  Alcohol Rapid Test Strip (Urine) is intended for the detection of ethyl alcohol in human urine. To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used.  TEST PROCEDURE 1. Open the pouch package and remove the test strip. 2. Dipping the strip into the urine specimen for at least 20 seconds. 3. After wetting the reaction pad by urine specimen, immediately remove the strip from the urine specimen. 4. Read the alcohol test results at 3 minutes. Compare the color of the reaction pad with the color card to determine the relative urine alcohol level.
Product Name Specimen Catalog No. Quantity per box Alcohol Strip Saliva ABT-ACH-A187 100T/50T KEY POINTS Detection for:  Alcohol in human saliva at a cut-off concentration of 0.02% (20mg/dL); Reading time:  2 minutes; Agreement:  98%.  INTRODUCTION of Drug Of Abuse Rapid Tests Two-thirds of all adults drink alcohol.1However, alcohol intoxication can lead to loss of alertness, coma, death and birth defects. The blood alcohol concentration (BAC) at which a person becomes impaired is variable. The United States Department of Transportation (DOT) has established a BAC of 0.02%(20mg/dL) as the cut-off level at which an individual is considered positive for the presence of alcohol. Determination of ethyl alcohol in urine, blood and saliva is commonly used for measuring legal impairment, alcohol poisoning, etc. Gas chromatography techniques and enzymatic methods are commercially available for the determination of ethyl alcohol in human fluids. ACCU-TELL ®  Alcohol Rapid Test Strip (Saliva) is designed to detect ethyl alcohol in saliva specimens.  INTENDED USE ACCU-TELL ®  Alcohol Rapid Test Strip (Saliva) is a One Step method for the detection of Alcohol in human saliva at a cut-off concentration of 0.02% (20mg/dL). This assay provides only a qualitative, preliminary analytical test result. An alternate, non-enzymatic technology must be used in order to obtain a confirmed analytical result. Headspace gas chromatography is the preferred confirmatory method.  Allow the pouched strip to equilibrate to room temperature (15-27 °C) prior to testing. Abstain from placing anything in the mouth for fifteen (15) minutes prior to beginning the test. This includes non-alcoholic drinks, tobacco products, coffee, breath mints and food, etc 1.     Open the pouch package and remove the test strip. Observe the reactive pad on the end of the test strip. If the reaction pad has a blue color before applying saliva sample, do not use. 2.     Saturate the reactive pad with saliva from collection cup or by applying saliva directly to the pad. (It usually takes 6-8 seconds to be saturated.) Start timer immediately after saliva application. 3.     Read result at two (2) minutes. Compare the color of the reaction pad with the color card to determine the relative blood alcohol level.
INTENDED USE â?? A rapid animal diagnostic test kit for simple antigen detection that can diagnose the presence or absence of distemper virus antigens in dog eye secretions (eye mucus, tears), droplets, and saliva within 10 minutes with a simple operation. Symptom of a disease â?? It is a highly contagious disease. The virus spreads more widely in young dogs than in adult dogs and has a higher mortality rate. Canine distemper is a serious viral disease with no known cure, and can be transmitted from dog to dog in the air or in direct contact. Typical symptoms are respiratory and intestinal problems, such as coughing, diarrhea, vomiting, runny nose, and loss of appetite.
A one-step rapid immunochromatographic test for the quantitative detection of specific antibodies to COVID-19 present in human serum, plasma, or whole blood.
All types of Rapid test kits
Covid rapid testing kits, masks, gloves.Sales and marketing including shipping
Products include antigen/antibody sars cov 2 kits, pcr test kits, nitrile gloves and antibody treatment.
Covid 19 Tests Machinery.
Surgical product, condoms, pregnancy test kit, covid test kit extra all product .
Cervical sampling brush, cervical sampling swab for hpv, cell preservation solution, cell culture flask, cell culture plate, petri dish, specimen collection flocked swab (ce0197 certificate), vtm sampling tube, pipette filter tips, virus transport medium, virus antigen rapid test kit, saliva collection kits, cotton swab, transport medium, pcr tube/plate.
Safety workwear, covid 19 products, safety shoes.