Specimen: Swab/Urine . Format: Cassette.
Specimen: Throat Swab. Format: Cassette/Strip.
Specimen: Whole Blood/Serum/Plasma. Format: Cassette.
Specimen: Urine. Format: Cassette/Strip/Mdistream.
Specimen:Feces. Format:Cassette/Strip.
Technical Specification: Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, and pH Test wavelength: 525nm, 572nm, 610nm, 660nm Test principle: Reflectance Photometer Suitable strips: DIRUI H8 and H10 urinalysis strips Test throughput: 120 strips/h or 60 strips/h optional Data memory: 1000 patient results Computer interface: RS-232 port Display: 128Ãí¬32 dot-matrix LCD Language: Chinese and English Power supply: 100~240VAC, 50Hz/60Hz Power: 25VA Printer: Built-in thermal printer Dimensions: 270mmÃí¬180mmÃí¬100mm Weight: 1.15kg
Technical specification: Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite,leukocytes, glucose, specific gravity, pH and VC Test wavelength: 525nm, 572nm, 610nm, 660nm Test principle: Reflectande Photometer Suitable strips: DIRUI H8, H10 and H11 urinalysis strips Test throughput:120 strips/h or 60 strips/h optional Data memory: 1000 patient results Computer interface: RS-232 port; parell printer port Display: 240Ãí¬64 dot-matrix LCD Language: Chinese and English Power supply: 100~240VAC, 50Hz/60Hz Power: 40VA Dimensions: 376mmÃí¬316mmÃí¬170mm Weight: 3.6kg
Technical Specification: Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, pH and VC Test wavelength: 525nm, 572nm, 610nm, 660nm Test principle: Reflectance Photometer Suitable strips: DIRUI H8, H10 and H11 urinalysis strips Test throughput: 514strips/h Data memory: 2000 patient results Computer interface: RS-232 port; parell printer port Display: 240Ãí¬64 dot-matrix LCD Language: Chinese and English Power supply: 100~240VAC, 50Hz/60Hz Power: 40VA Printer: Built-in thermal printer Dimensions: 380mmÃí¬378mmÃí¬275mm Weight: 6.5kg
Specification: Wavelength range:340nmíó405nmíó450nmíó492nmíó505nmíó546nmíó578nmíó630nm available Wavelength Accuracy: Âí+2nm Spectrum bandwidth: 6-12nm Absorbancy:-0.3í½3.0 ABS Resolution: Display with 1m ABS , internal with 0.1m ABS Linearity: less than 0.5% within 1ABS Stability: 20 minutes for warm-up and then í_3mABS/hour Measure repeatability : 2m ABS Measurement time: 0í½999s programmable Delay time: 0í½999s programmable Memory: 200 testing programs , 3000 testing results Sampling: 100í½9999ª¦l programmable Microflowcell volume :32ª¦l Cross-contamination: í_1% Differentiation rate: í_1% Absorbancy repeatability: í_1% Display: Matrix LCD Power consumption: 85w Dimension:462X418X232mm Weight:6.5KG
Technical Specification WBC HGB LYM% LYM% MON% MON% GRA% GRA% HCT RBC MCH MCV RDW-CV MCHC RDW-SD PLT PCT MPV PDW P-LCR RBC histogram WBC histogram PLT histogram Calibration: manual calibration, automatic calibration,fresh blood calibration Cross contamination rate: WBC,RBC,HGB
Hcg rapid diagnostics test kits(ce & iso)
HCV rapid diagnostics test kits(ce & iso)
Glucose rapid diagnostic test kits(ce & iso)
Rapid diagnostic test kits
Toyota tester The intelligent tester ii is designed to fully utilize the enhanced vehicle on-board diagnosis function such as improvement of data refresh rate (can protocol), enhancement of freeze frame data and active test function and so on. As an aid in diagnosing electrical and electronic control system, it is capable of monitoring and testing electronic control units (ecus) for powertrain, chassis and body systems and their associated sensorsand actuators. Easy and fast usb connection will realize tight integration with personal computer (pc) based applications and systems. The intelligent tester ii has an ability of future extension via generic memory card slot and change of the optional unit. The wireless communication with pcs will be possible by using wireless card in the future.
Ad-200 auto scanner Ad-200 is the new generation obd& can scanner, handheld with large lcd, easy to use! Updating available now! Function 1.Displays the dtc definitions on screen unlike previous models. 2.Wider coverage: works with can¬\equipped vehicles. 3.Reads and clears all generic, and some manufacturer, specific dtcs. 4.Resets check engine lights. 5.Views obd¬\ii freeze frame data. 6.Determines the malfunction indicator lamp (mil) status. 7.Displays i/m readiness status. 8.Retrieves the vehicle identification number (vin). 9.Scanning live data. 10.Saves scanning data. Features 1.Display: 128x64 pixel lcd with contrast adjustment and backlight. 2.Easy¬\to¬\read screen and also saves up to 38 scans for later viewing. 3.Operating temperature: -20íµ to 50 íµ(¬\4¿h to 122 ¿h). 4.Operation voltage: dc 9 ~15v provided by vehicle battery. 5.Supplying text in 11 languages: englishíógermaníófrenchíóitalianíódenishíódutchíóspanishíóportugueseíófinnishíónorwegianíóswedish. Support protocol 1.Sae-j1850 pwm. 2.Sae-j1850 vp. 3.Iso-14230. 4.Iso-9141. 5.Iso-15765-4 (can bus).
Bmw ops Ops is mainly used for diagnosis and programming bmw vehicles after e65 series. Ops unit with dis software is used for diagnosis, which is carried out via obd-ii socket. Config 1.Ops multiplexer. 2.Obd-ii diagnostic cable. 3.Most diagnostic cable. 4.Lan cable. 5.Sss pc(optional). 6.Ibm t23/t30 (optional). 7.Dis 80g hd (optional). 8.Wireless card (optional). 9.Toolbox(optional).
Vacuum blood collection tube Plastic and glass material *serum: red cap , 3ml 5ml 7ml, 13*75mm 13*100mm *3.2 goagulation, blue cap, 1.8m 2.7ml , 13*75mm 13*100mm *gel clot activator, yellow cap, 3ml 6ml, 13*75mm 13*100mm *edta-k3, k2, purple cap, 2ml 5ml, 13*75mm 13*100mm *heparin, green cap, 1.8m 2.7ml , 13*75mm 13*100mm *glucose, gray cap, 2ml 3ml, 13*75mm 13*100mm *3.8% black cap , 1.6m 2.4ml , 13*75mm 13*100mm Packing: 13*75mm 1000pcs/ctn 13*100mm 800pcs/ctn
Hcg pregnancy test, strip, 2.5mm, 3mm Hcg pregnancy test, cassette, 3mm, 4mm Hcg pregnancy test, midstream, 6mm Oem 1000pcs/ctn 2000pcs/ctn
Honda diagnostic system kit Description: This interface module kit works with the oem-honda diagnostic pc software (hds). It can diagnose all honda and acura vehicle systems on models from 1992 to year 2008, including can-bus system. Functions supported by honda/acura protocols: Reading and decoding fault codes from control blocks' memory; Deleting fault codes; Displays system's current parameters in digital form; Displays system's current parameters in graphical form; Combined displaying of data; Management of executive devices; Logs keeping - writing and keeping of digital parameters in memory; Special functions - changing of permissible settings of blocks, programming etc. Functions supported by obd-ii protocols: Mode 1 - displays system's current parameters in digital form (up to 8 parameters at once); Mode 2 - displays parameters of "freeze" frame; Mode 3 - reading and decoding of fault codes from control block's memory; Mode 4 - deleting of fault codes (memory clearing); Mode 5 - displays results of oxygen sensors; Mode 6 - displays results of changeably controled systems and components; Mode 7 - displays results of constantly controled systems and components; Mode 8 - management of executive devices; Mode 9 - displays car's identification info. Hardware and software requirements: Pc or laptop with either windows 2000 professional (sp4 or later) or xp (sp1 or later) Hard disk drive with at least 400mb of free space Cd-rom drive (if a high-speed internet connection is not available) Rs232 port required to connect pc to him (pc version software only) Monitor capable of displaying in vga mode or above (1024 x 768 recommended) Internet connection (high-speed connection recommended) Honda diagnostic system kit includes: 1 x him with obd ii cable 1 x dvd 1 x 3 pin cable 1 x rs232 cable 2 x selftest adapter 1 x storage case Net weight: 3.5kg