3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: ín1.5 minute per sample Up to 100, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing, block clearing Color lcd display 272mm(l)íß 420mm(w)íß 390mm(h) 24kg
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
Fully automated, compact, flexible and low cost 3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: 60 samples per hour Automatic diluting, lying, mixing, rinsing and clog-clearing Automatic sample probe cleaning Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Reagent expired alarm Color lcd display 40cm(l)40cm(w)46cm(h) 25kg
12 predetermined animals + 4 options, Wbc 3 part diff 19 parameters + 3 histogram 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
80 samples per hour--- Fully auto cap piercing sampler--- Sample rotor valve technology--- Parameters: 19 parameters + 3 histograms Principle: electrical impendence for counting and sft method for hgb Throughput: up to 80 samples per hour Sampler capacity: 50 samples Testing mode: manual open(whole blood, prediluted); sampler close(whole blood) Sample volume: sampler mode: whole blood 200 ª8l Manual mode: whole blood 200ª8l; prediluted 40ª8l Aperture diameter Wbc: 100ª8m Rbc/plt: 80ª8m Memory: 35, 000 results with histogram Performance: Parameters precision cv% Wbc(10 /l) 2.0% Rbc 1.5% Plt 4.0% Mcv(fl) 0.5% Hgb(g/dl) 1.5% Display Large color lcd, displays all parameters result with histogram of wbc, rbc and plt Resolution: 800íß600 Menu Count, sample mode, review, quality control, system setting, reference value, system service, calibration, copyright, shutdown Alert: 25 sets of alert message Input/output: usb(keyboard, mouse, flash disk), rs232, parallel Print:graphic thermal printer with various printing format, optional external printer Operating environment: Temperature: 18-30íµ Humidity: ín70% Power requirement: Ac100-240v, 60/50hz Dimension 600mm(l)íß520mm(w)íß57 0mm(h) Weight 30kg
Rapid HCG Pregnancy Test Card Intended Use HCG Pregnancy Urine Test is a chromatographic immunoassay for the early detection of human chrionic gonadotropin (HCG) in urine specimens. Contents of Kit HCG Pregnancy Test Card 25 ea Instructions For Use 1 ea Storage And Stability The kits should be stored at temperature 4-30ípC in the sealed pouch for the duration of the shelf life. Pre Cautions 1. For in vitro diagnostic use only. 2. Do not use after expiration date. 3. Test device should remain sealed until use. 25 tests/kit, 40 kits/carton
Rapid Malaria pf/pv Antigen Test Card Intended Use Malaria pf (HRP II) / pv (LDH) Antigen Test is for the rapid qualitative determination of Malaria P. falciparum specific histidine rich protein-2 (Pf HRP-2) and Malaria P. vivax specific lactate dehydrogenase (pvLDH) in human blood as an aid in the diagnosis of Malaria infection. Contents of Kit Malaria pf/pv Antigen Test Card 25 ea Malaria Sample Buffer 1 ea Instructions For Use 1 ea Storage And Stability The kit can be stored at room temperature or refrigerated (4-30ípC). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date. Pre Cautions 1. For professional in vitro diagnostic use only. Do not use after expiration date. 2. Do not eat, drink or smoke in the area where the specimens or kits are handled. 3. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens. 4. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are being tested. 5. Humidity and temperature can adversely affect results. 25 tests/kit, 40 kits/carton
Nabl accredited blood testing lab - complies with iso 15189- offers clinical research among others. Na
All of our products are ce, fda and iso 13485 certificated with competitive price (negotiable) and warranty in international market. Meanwhile, excellent services and prompt delivery help us win great fame among customers. 1. Convenient, reliable results, capillary action strips allow a quick and simple application of blood. In only 20 seconds, the meter produces an accurate reading. 2. Less painful results, requires only 3ul of blood and allows testing on forearm and palm. 3. Affordable results. Frequent testing helps improve control. 4. Information to better manage diabetes. Memory feature stores up to 30 tests and provides 7, 14 and 30-day averaging. One kit of glucose testing system includes all the following Biocare blood glucose meter 10 test strips (free) One adjustable lancet device 10 sterile lancets (free) Ownerí»s booklet One carrying case Two 3.0v lithium batteries (installed) Specifications Measuring range: 2.2-27.8mml/l (40-500mg/dl) Measuring time: 20 seconds Memory capacitance: 30 Power source: two replaceable 3-volt batteries (cr2032) Batteries life: > 1000 tests Life of test strips: 12 months (vial sealed), 3 months (after vial opened) Volume of blood: 3ul Net weight: 52g Dimensions: 97(l)*55(w)*15(h) mm Item: glucose meter and testing strip Model no.: sg-1 Description: 97(l)*55(w)*15(h) mm Package: color box Moq: 500pcs for meters , 1000bottles for strips(50strips/bottle) Ctn size: 72*58*54cm , 35*22*51.5cm Q'ty/20': 2100pcs; q'ty/40': 4200pcs Loading port: shanghai Payment terms: t/t in advance, l/c, etc. Valid time: 60 days
All of our products are ce, fda and iso 13485 certificated with competitive price (negotiable) and warranty in international market. Meanwhile, excellent services and prompt delivery help us win great fame among customers. 1. Convenient, reliable results, capillary action strips allow a quick and simple application of blood. In only 20 seconds, the meter produces an accurate reading. 2. Less painful results, requires only 3ul of blood and allows testing on forearm and palm. 3. Affordable results. Frequent testing helps improve control. 4. Information to better manage diabetes. Memory feature stores up to 30 tests and provides 7, 14 and 30-day averaging. One kit of glucose testing system includes all the following Biocare blood glucose meter 10 test strips (free) One adjustable lancet device 10 sterile lancets (free) Ownerí»s booklet One carrying case Two 3.0v lithium batteries (installed) Specifications Measuring range: 2.2-27.8mml/l (40-500mg/dl) Measuring time: 20 seconds Memory capacitance: 30 Power source: two replaceable 3-volt batteries (cr2032) Batteries life: > 1000 tests Life of test strips: 12 months (vial sealed), 3 months (after vial opened) Volume of blood: 3ul Net weight: 52g Dimensions: 97(l)*55(w)*15(h) mm Item: glucose meter and testing strip Model no.: sg-1 Description: 97(l)*55(w)*15(h) mm Package: color box Moq: 500pcs for meters , 1000bottles for strips(50strips/bottle) Ctn size: 72*58*54cm , 35*22*51.5cm Q'ty/20': 2100pcs; q'ty/40': 4200pcs Loading port: shanghai Payment terms: t/t in advance, l/c, etc. Valid time: 60 days
Specification: 18.8 x 11.6 x 7cm These belt kit is good for mountain climbing as well as other outdoor activities. It is also suitable for troop use.
We sell all braded glucose meters and test strips from bayer, roche, abbott, livescan.J&j, siemens multistix 10sg 38-59-60
Diatermo mono-bipolar Our Diatermo 160, by selecting the modes of operation, provides cut pure cut, coagulated cut, forced coagulation, soft coagulation and û with forceps û bipolar coagulation. It is particularly suitable for very damp operational fields such gynaecological and orthopaedic surgery. The Leading-Edge Technology enables highly professional surgery intervention; Open Circuit (OC) Alarm warns the user that connection into the neutral plate has not been made or that the cable is disconnected or the neutral plate is not in contact with the patient; in this case HF emission for cut and coagulation operation is switched off. Gima offers a wide family of Diatermo and accessories. Models 106 and 108 are monopolar units (50/80 W) suitable for small operations are ideal for veterinary, dentistry, first aid and dermatology work. All the other Gima mono-bipolar models (120/160/200/250/380/400 W) cover all the operational fields, from middle electrosurgery to surgery where high precision and reliability are essential, as endoscopy surgery. The available accessories are monopolar forceps, scissors and cables, high quality insulated bipolar forceps and cables, autoclavable electrodes, single use sterile electrodes, single use, metal and rubber plates, monopolar handles (with or without switches), footswitches and board.
Our test strips can be used with the one touch, ultra blood glucose meters. They are simple in operation , convenient and quick in using without any testing equipment. Our products are superior in quality. We also can supply with oem. í¦customerí»s satisfaction is our greatest successí¦ is our principle. Neutral packing
Nitrofuran (amoz) elisa test kit Technical specifications Sensitivity : 0.1ppb Detection limit: Tissue (some interference in shrimp and fish)--0.3ppb Tissue and honey-0.2ppb Recovery rate Tissue (shrimp and fish)--90+15% Honey , chicken meat /liver-80+15% Cross-reaction rate: Amoz 100% Ahd 0.1% Aoz- t0.1% Sem- t0.1% Weight:1.5kg Dimensions:24cm*16cm*11cm
Chloramphenicol elisa test kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of chloramphenicol in the tissue (chicken, pork), honey, milk, fish, shrimp and egg. The coupling antigen is pre-coated on the micro-well stripes. The chloramphenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against chloramphenicol. After the addition of the enzyme conjugate, the tmb substrate is added for coloration. The optical density (od) value of the testing sample has a negative correlation with the content of chloramphenicol in it. This value is compared to the standard curve and the content of the corresponding chloramphenicol is subsequently obtained. 2. Technical specifications Sensitivity : 0.05ppb Detection limit: Egg, intestine0.1 ppb Honey0.15ppb Milk0.05 ppb Urine and serum0.1 ppb Chicken, pork, fish, shrimp0.05 ppb Recovery rate Chicken, pork, fish, shrimp80%+10% Honey70%+10% Milk85%+15% Cross-reaction rate: Chloramphenicol100% Thiamphenicol
Ractopamine elisa test kit Technical specifications Sensitivity : 0.5 ppb Detection limit Muscle 1ppb Liver--2ppb Urine-1ppb Admixture-25ppb Contrated material , premix material-75ppb Recovery rate Urine--85+10% Muscle and liver--80+10% Cross-reactions Ractopamine---100% Dobutamine-10% Clenbuterol 0.1% Salbutamol -0.1% Weight:1.5kg Dimensions:24cm*16cm*11cm
Diagnostic set
In strip, cassette, midstream. ISO9001,ISO13485,CE Differen packing, different specification.
The LH Ovulation Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-36 hours 1) Format: strip 2) Specimen: Urine 3) Sensitivity: 25 mIU/ml 4)Packing: 1 test/bag 5) Our products are CE certified products. 25T/box, 1500T/ctn.