Medical equipments, covid 19 antiviral pills.Transportation and shipping
Covid test kits, nitrile gloves, nanotechnology surface disinfectants.
Covid 19 health test kits, pulse oximeter mask ,gloves, alcohol mat.
Nitrile gloves, n95 masks, test kits, ventilators.
Covid 19 test kit, dengue rapid test, syphilis rapid test and pregnancy rapid test and others.
Fda and ce approved examination gloves,. brands include cardinal, kimberly clark, v glove. also we can provide covid 19 rapid antigen test. test with reliable results within minutes. made in the usa. lateral flow assay, no equipment required, results within 10 minutes, minimally invasive specimen collection, nasal swab, poc (in patient care setting). detects sars cov2 nucleocapsid protein antigen with ultra high performance. identifies acute infection with 88.4% sensitivity and 100% specificity. complies with fda. principals or buyer's mandates only. no broker chains..
Pcr test kit, n95 , nitrile gloves, face shields.
S&M PRP Unique System It has the capacity to take 14 ml of blood. After the centrifuge, the Buffy Coat is adjusted to the narrow section in the middle and collected very comfortably with the injector from the top cap. It gives high platelet concentration. PRP collection problem in double and single cap tubes is almost non-existent with this design. High quality PRP is obtained in every application. Since the design structure is similar to Hourglass, it is also called Hourglass PRP.
Syphilis rapid test igg/igm antibodies (uncut sheet) Specimen: whole blood/serum/plasma Format: 3.0mm Accuracy:99.6% Cut-off:2ng/ml Sensitivity:100% Package: in bulk or unit box package for your options Delivery date:7-10 days after receipt of the payment Pouch design: white pouch / netrual/ oem design/ce marked Payment:westren union, t/t
HCV Rapid Test Antibodies (Uncut Sheet) Specimen: Whole Blood/Serum/Plasma Format:2.5mm 3.0mm 4.0mm Accuracy:99.6% Cut-off:2nCU/mL Sensitivity:99.8% Specificity:99.5% Package: in bulk or unit box package for your options Delivery date:7-10 days after receipt of the payment Pouch design: white pouch / netrual/ OEM design/CE Marked Payment:Westren Union,T/T
Tb(tuberculosis) rapid test antibodies (uncut sheet) Specimen: whole blood/serum/plasma Format:2.5mm 3.0mm 4.0mm Accuracy:99.6% Sensitivity:100% Specificity:98.2% Package: in bulk or unit box package for your options Delivery date:7-10 days after receipt of the payment Pouch design: white pouch / netrual/ oem design/ce marked Payment:westren union, t/t
Hbsag rapid test antigen (uncut sheet) Specimen: whole blood/serum/plasma Format:2.5mm 3.0mm 4.0mm Accuracy:99.5% Cut-off:1.0ng/ml(whole blood), 2.5ng/ml(s/p) Sensitivity:99.8% Specificity:99.5% Package: in bulk or unit box package for your options Delivery date:7-10 days after receipt of the payment Pouch design: white pouch / netrual/ oem design/ce marked Payment:westren union, t/t
Shelf lifespan: 18 months Sensitivity: 92.23% Specificity: 95.34% Other rapid test kits could be optional, such as fertility, sexual transmitted diseases test, cardiac marker test, tumor marker test, drugs of abuse test, infectious disease test, biosecurity and miscellaneous test
Canine Distemper Virus Ag Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Canine Distemper Virus (CDV Ag) in dog's secretions or serum. Assay Time: 5 -10 min Sample: Secretions or serum
Feline Leukemia Virus Ag Rapid Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Feline Leukemia Virus antigen (FeLV Ag) in cat's blood. Assay Time: 10 -15 min Sample: serum, plasma or blood Feline Leukemia Virus Ag Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FeLV antigen in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FeLV antigen in the sample.
Canine Heartworm Ag Rapid Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Dirofilaria immitis (CHW Ag) in dog' s blood, serum or plasma. Assay Time: 5 -10 min Sample: Serum, plasma or blood Canine Heartworm Ag Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When a sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough CHW antigen in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Dirofilaria immitis antigen in the sample.
Canine Parvovirus Ag Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of canine Parvovirus (CPV Ag) in dog's feces or vomit. Assay Time: 5 -10 min Sample: Feces or vomit Canine Parvovirus Ag Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough Parvovirus antigen in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Canine Parvovirus antigen in the sample.
Rapid SAR-CoV-2 (Covid-19) Test Kits: FDA & CE Approved (Results in 15 min). SAR-CoV-2 IgG/IgM Rapid Test Cassette is a qualitative membrane based immunoassay for the detection of IgG and IgM antibodies to SAR-CoV-2 in human whole blood, serum or plasma specimen. Made in China: FDA and CE Approved, China NMPA approval (export allowed) One of the earliest CE (Feb 2020) and FDA (Mar 2020) approved kit. Clinically studied and reliable. Packaging: 20 sets/box or 40 sets/box. Payment term: MOQ 2000 sets, FOB China $ 9.5/set. < 10000 sets 100% advance payment > 10000 sets L/C ex-work on site
VETLabs Toxoplasma IgM/IgG test is a sandwich lateral flow immunochromatographic assay, developed and manufactured by Bioguard Corporation, for the rapid and qualitative detection of Toxoplasma IgM/IgG in cat's blood. The test device has a testing window, coated by an invisible T (test) zone and C (control) zone. When a sample is applied to the sample well on the device, the reagent will laterally flow on the surface of the test strip. If there is enough Toxoplasma IgM/IgG in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid test. By the means, the device can accurately indicate the presence of Toxoplasma IgM/IgG in the specimen. Kit components: 5 test per box and/or 10 test kit per box in an individual foil pouch with a desiccant and disposable dropper, EDTA blood collection tube, Assay buffer bottle, Instruction manual
VETlabs Canine Parvovirus (CPV) Ag/Canine Coronavirus (CCV) Ag Combo test is a sandwich lateral flow immunochromatographic assay, developed and manufactured by Bioguard Corporation, for the rapid and qualitative detection of Caine Parvovirus and Canine Coronavirus in dog's feces. The test device has a testing window, coated by an invisible T (test) zone and C (control) zone. When sample is applied into the sample well on the device, the reagent will laterally flow on the surface of the test strip. If there is enough CPV Ag/CCV Ag in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of CPV Ag/CCV Ag in the specimen.