Lipstick metal holder& soft rubber mold (silicone mold)
Plastic pencil mold
Wood pencil lead mold
Capacity
45-60 lipsticks/min (depended on the mold type)
Features
Servo controlled mold raise /lower system
Automatic feed mold into/out of conveyor
Automatic lipstick releasing by robot
Cover of mold be put back with automation
Mould recycling with automation
Releasing unit designed for easy taking out from mold
Operation with digital input by plc interface
Parameters
Voltage Ac220v/50hz
Weight 550kg
Body material T651+sus304
Dimensions 2500*1200*1700
Specification
Design for two tunnel with 2-4 station (option) and frost moving
Stainless steel 304 frame
Temp control by digital t.I.C
Conveyor speed and cooling temp controlled according to the type of product
Parameters
Applications
1. Remove unwanted hairs;
2. Remove facial vascular lesions (telangiectasis);
3. Clean and tighten visible pores;
4. Smooth fine wrinkles;
5. Make skin more flexible;
6. Improve the tone of skin and remove facial blemish;
7. Remove acne;
8. Skin whitening
Treatment principle
E-light combines three advanced technologies: bipolar radio frequency + ipl +skin contact cooling. When the three are united in one treatment, wonderful treatment experience and result can be expected. The energy of radio frequency can reach the middle and deep layer of the skin and heat up tissue, thus, lower energy is applied during the ipl treatment. Ipl energy has been absorbed by pigment, so pigment tissue has been heated enough to be broken down into lots of tiny particle, then they are metabolized through lymphatic system, so effect can be achieved perfectly. Uncomfortable feeling during the ipl treatment will be decreased significantly and better result can be expected. In addition, cooling system involved in e-light can also ease the uncomfortable feeling. The absorbing of the energy of radio frequency is not concerned with melanin. So, the e-light treatment can get good result on the soft or thin light color hair so as to decrease the risk caused by traditional ipl treatment
Advantages
1.Designed according to abundant clinical data worked out by many famous clinical doctors;
2.Advanced technology: ipl+rf, can achieve the best effect.
3.Stainless components gurantee best quality.
4.Separate filters(sapphire) make treatment more professional and accurate.
5.Professional refrigeration system(-5¡ãc-0¡ãc) make treatment more comfortable.
6.Large colar touch lcd screen make operation more convenient
Net weight
35kg
Power
1200w
Dimension
500mm¡¨¢400mm¡¨¢1050mm (l¡¨¢w¡¨¢h)
Electrical requirement
Ac 220v¡¨¤10% 50hz
Ac 110v¡¨¤10% 60hz
Ipl series equipments can be explained by optional light pyrogenation. The melanin absorbs short wavelength of 250-1200nm, maximum absorbing values of the bright-red chemical complex of hemoglobin and oxygen are 418nm, 542nm, 577nm. Therefore, it can be absorbed easily and transported to the collagen layer. 530nm waveband light releases from the probe, which produce pyrogenation of the collagen fiber. Collagen fiber can absorb large light of 400-600nm, also including some light of 530-1200nm releases from the probe, which will result in the injury of the collagen fiber, enhance the activationof the cells and the collagen synthesis. Repristination of i collagen and iii collagen which contains in blood vessel. Then, skin rejuvenation treatment will be effective on pigments dispelling, telangiectasia lightening, fine wrinkle lightening, shrinking pores.
Application:
Power supply 110v/220v, 50hz/60hz, 6a/3a 800w
Dimension 52*45*48cm
Weight 35kg
Produced.
Energy reaches the root of the hair follicle solely through melanin. Skin and red blood cells have a similar absorption
Coeff icient as melanin and therefore also absorb the high levels of energy produced by the laser and ipl methods.
Shr technology, on the other hand, utilizes the melanin path only partially (50%)., and combining in-motion technology,
Gently warms the skin helping penetrate down to the follicles which produce hair growth.
Research has shown that a slower, but longer heating process is considerably more effective for permanent hair removal than high and short levels of energy. Therefore, when using shr, the device is passed over the tissue multiple times (in motion) using low energy but a high rate of repetition (up to 10hz, i.E. 10 times per second) instead of using the traditional method with single, highenergy impulses. Thus, the hair melanin, as well as the tissue of the stem cells, is heated with low energy at a slow pace and over a longer period of time to a comfortable temperature of 45¡ã celsius.
Features
Designed for gear pump filling system
1 set of 3 layer jacketed barrel 25l capacity with stirrer
Electronic timer control filling volume
Dosing volume and gear pump speed controlled by digital input, accuracy +/-0.5%
Automatic preheating and turn off system.
Operation with plc
Parameters
Voltage, a c220 v/50 hz
Weight, 100 kg
Body material, s u s 304 frame
Dimensions, 500*730*1700 (mm)
Operator, 1
Target products
All types of lipsticks
Capacity
30-50 lipsticks/min (depend on the mold type)
Mould types
Soft rubber mold by vacuum
Metal mold (bottom air hole type) by air blowing
Aluminum mold (bottom without air hole type)
Plastic/wood pencil lead mold
Parameters
Dimensions, 650*520*1500
Body material, t651+sus304
Voltage, ac220v/50hz
Weight, 70kg
Operation, 1 operator
Gillette Fusion is the first and only shaving system that has revolutionary technology on the front and the back of the cartridge. The Precision Trimmer Blade is built into the back of the cartridge. Perfect for tricky places like sideburns, under the nose and around facial hair. Gillette Fusion Blades have an enhanced indicator lubrastrip which has vitamin E and aloe, and fades to white when you are no longer getting your optimal shave. The flexible comfort guard gently sets up the beard to help comfortably shave you incredibly close.