Industry - Welding, Oil & Gas, Petrochemicals, Electrical etc. Shell Composition - GDI32 - Modacrylic:Cotton:P-Aramid:Antistatic, IFR, 180 GSM GDI49 - Modacrylic:FR Viscose:M-Aramid:Antistatic (IFR), 230-300 GSM GDI37 - Cotton:Antistatic with FR Treatment, 240 to 350 GSM. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - General :- EN ISO 13688, EN ISO 20471, ISO 15797 Arc :- EN 14116, EN 11611, EN 11612, NFPA 2112 Fire :- EN 61482, EN 1149, NFPA 70E.
Industry - Welding, Oil & Gas, Petrochemicals etc. Shell Composition - GDI36-100% Cotton with FR Treatment. Weight - 200 GSM to 320 GSM. Size - XS to 5XL (ASIA), 34 to 60 (US), 34R to 60R (UK), 44 to 70 (EU). Safety Performance - General :- EN ISO 13688, EN ISO 20471, ISO 15797 Arc :- EN 14116, EN 11611, EN 11612, NFPA 2112 Fire :- EN 61482, EN 1149, NFPA 2112.
Industry - Construction, Physical Works, etc. Shell Composition - 100% Cotton Polyester Blends Nylon Blends Viscose Blends Quilting - Padding: 100% Non-woven Polyester Lining : 100% Polyester fabric Weight - 200 GSM to 400 GSM. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - EN-ISO 13688, EN-ISO 20471, ISO 15797.
Industry - Welding, Oil & Gas, Petrochemicals, Electrical etc. Shell Composition - GDI32 - Modacrylic:Cotton:P-Aramid:Antistatic, IFR, 180 GSM GDI49 - Modacrylic:FR Viscose:M-Aramid:Antistatic (IFR), 230-300 GSM GDI37 - Cotton:Antistatic with FR Treatment, 240 to 350 GSM. Quilting - Middle Layer - Normal wadding or FR wadding as per needs Inner Layer - Normal lining or FR lining as per needs. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - General :- EN ISO 13688, EN ISO 20471, ISO 15797 Arc :- EN 14116, EN 11611, EN 11612, NFPA 2112 Fire :- EN 61482, EN 1149, NFPA 70E.
Industry - Welding, Oil & Gas, Petrochemicals etc. Composition - GDI36-100% Cotton with FR Treatment. Weight - 220 GSM to 320 GSM. Size - XS to 5XL (ASIA), 34 to 60 (US), 34R to 60R (UK), 44 to 70 (EU). Safety Performance - General :- EN ISO 13688, EN ISO 20471, ISO 15797 Arc :- EN 14116, EN 11611, EN 11612, NFPA 2112 Fire :- EN 61482, EN 1149, NFPA 2112.
Industry - Welding, Oil & Gas, Petrochemicals, Electrical etc. Composition - GDI32 - Modacrylic:Cotton:P-Aramid:Antistatic IFR, 180 GSM GDI37 - Cotton:Antistatic with FR Treatment, 240 to 350 GSM GDI49 - Modacrylic:FR Viscose:M-Aramid:Antistatic (IFR), 240 GSM Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU) Safety Performance - General - EN ISO 13688, EN ISO 20471, ISO 15797 Arc - EN 14116, EN 11611, EN 11612, NFPA 2112 Fire - EN 61482, EN 1149, EN 2112
Industry Welding, Oil & Gas, Petrochemicals etc. Composition GDI36-100% Cotton with FR Treatment Weight 220 GSM to 350 GSM Size - XS to 5XL (ASIA), 34 to 60 (US), 34R to 60R (UK), 44 to 70 (EU) Safety Performance General :- EN ISO 13688, EN ISO 20471, ISO 15797 Arc :- EN 14116, EN 11611, EN 11612, NFPA 2112 Fire :- EN 61482, EN 1149, EN 2112
Industry - Defense. Outer Shell - 100% Nylon 66, 150 GSM FR Treatment Optional Camouflage printing. Middle Layer - Activated Carbon Fabric with nanopore structure. Inner Layer / Lining - Cotton: Polyester blend with Antimicrobial Treatment Cotton : Viscose blend with Antimicrobial Treatment. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU).
Industry - Fire fighting. Outer Shell - GDI86A - 100% Para Aramid Aluminised (Inherent FR) GDI86F - 100% Fiberglass Aluminised (Inherent FR). Middle Layer - Optional use of GDI89 - Thermal / Moisture Barrier. Inner Layer / Lining - GDI33 - 93% Meta-Aramid 5% Para- Aramid 2% Antistatic (Inherent FR), 150 GSM GDI32 - Modacrylic Cotton Para Aramid Antistatic, 180 GSM GDI36 - 100% Cotton with FR Treatment, 240 GSM. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - EN-ISO 13688, EN-ISO 20471, EN-14116, EN-11611, EN-11612, EN-61482, EN-1149, EN 1486, NFPA 70E, NFPA 1971, NFPA 2112.
Industry - Fire fighting. Outer Shell - GDI33 - 93% Meta-Aramid 5% Para- Aramid 2% Antistatic (Inherent FR) Weave - Ripstop Weight - 220 GSM. Thermal & Moisture Barrier - GDI89 - Meta Aramid - PU-FR Para- Aramid, 140 GSM with PTFE lamination Non-woven Weight - 140 GSM. Inner Layer / Lining - GDI33 - 93% Meta-Aramid 5% Para- Aramid 2% Antistatic (Inherent FR) Weave - Plain Weight - 150 GSM. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - EN-ISO 13688, EN-ISO 20471, EN-14116, EN-11611, EN-11612, EN-61482, EN-1149, EN 469, NFPA 70E, NFPA 2112, NFPA 1971.
Industry - Fire fighting. Composition - GDI33 - 93% Meta-Aramid 5%, Para- Aramid 2%, Antistatic (Inherent FR) Weave - Ripstop Weight - 220 GSM. GDI33 - 93% Meta-Aramid 5%, Para- Aramid 2%, Antistatic (Inherent FR) Weave - Plain / Twill Weight - 200 GSM. Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - EN-ISO 13688, EN-ISO 20471, EN-14116, EN-11611, EN-11612, NFPA 2112, NFPA 70E, NFPA 1971, EN-61482, EN-1149.
Industry - Foundries, Iron Industry, Aluminium Industry, Other metal industries etc. Composition - GDI36-35 100% Cotton with FR Treatment, 350 GSM GDI36-45 100% Cotton with FR Treatment, 450 GSM GDI43J Wool: FR Viscose : Nylon (Inherent FR) GDI43L Modacrylic : FR Viscose : Para- Aramid : Cotton : Antistatic (Inherent FR). Size - XS to 5XL (ASIA) 34 to 60 (US) 34R to 60R (UK) 44 to 70 (EU). Safety Performance - EN-ISO 13688, EN-ISO 20471, EN-14116, EN-11611, EN-11612, EN-61482, EN-1149, NFPA 2112, NFPA 70E.
Firefighter Reflective / Protective Clothing (Bracket Support) Firefighter protective Clothing: 2019 models: Clothing outer fabric: The use of 210g arylon three anti-fabric, which not only has a permanent flame retardant, high temperature resistance, acid and alkali resistance and other properties, and its strong performance is very excellent, with high heat insulation, permanent flame retardant, high strength, anti-cutting, acid and alkali resistance, arc resistance and other characteristics, improve the overall protection performance of clothing, clothing overall main technical parameters are much higher than the industry standard and bidding technical requirements. The fire retardant performance of the firefighter\'s fire extinguishing suit: the warp and weft continuous burning time is 0s, the warp and weft damage length is less than 51mm; Breaking strength: longitude and latitude 1000N; Tear strength: longitude and latitude 120N; Moisture resistance 3, thermal stability: change rate 1.0%; Color fastness: Color resistance 4, water friction resistance 4. Waterproof breathable heat insulation layer: aramid non-woven fabric and flame retardant PTFE film, gram weight 180g/m2. It can not only prevent the infiltration of water and other general liquid chemicals, but also discharge a large amount of hot gas generated in the body during fire rescue in time. The fabric has hydrostatic pressure & 50kPa, moisture permeability 5439g/m2/24h, oil-repellent performance 3, and thermal shrinkage 1%. Comfort layer: The use of intermediate arylon fiber and flame retardant viscose fiber blended, gram weight 125g/m2, flame retardant performance, thermal stability and other properties are very good. Size: S/M/L/XL