UTP Cat6 Network Cable
Standard:astm b230, b231, b232, b399, icea s-61-402 and s-66-52 Voltage:600/1000v Capacity:10000km/week The product is used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as a bare conductor. Ease of erection and stringing Practically no tree-trimming required Less maintenance Relative immunity to short circuits caused by external forces (wind, fallen branches), unless they abrade the insulation.
Capacity:2000ton/month Zinc coated carbon steel offers some corrosion resistance. G1070 is the most common grade used in aircraft cable and wire rope. It remains ductile over long periods of working. Usually higher break strengths than stainless steels. Utilities are all available It forms a coating of corrosion-resistant zinc which prevents corrosive substances from reaching the more delicate part of the metal It forms a coating of corrosion-resistant zinc which prevents corrosive substances from reaching the more delicate part of the metal+ Applicable standards: Astm a475 standard Astm a 363 standard Bs 183 standard Other international standard
Standard:astm b415, astm b416, din48201 etc Capacity:2000ton/month Corrosion resistant in industrial, semi-industrial and marine environments Superior to aluminized steel Lightweight Same tensile strength as extra high strength steel but weighs 15 percent less Excellent conductivity much more conductive than galvanized steel and aluminum Wider variety of properties and size of steel wire, thickness of aluminum cladding, and quality of aluminum (cross sectional area ratio of the aluminum in as wire covers approximately 13% to 85% while that designated in astm b415-92 is fixed at 25%) Wider range of combinations of tensile strength and conductivity Sufficiently strong bonding strength at the boundary between aluminum layer and steel core Lighter in weight than galvanized and aluminized steel wire Excellent thermal stability for continuous operation in high temperature
Standard:aisi 316 grade stainless steel Capacity:2000ton/month Stainless steel cable & stainless wire rope is highly corrosion resistant & decorative. Excellent for marine rope rigging, stainless steel cable railing, architectural cables, cable balustrades and cable display systems. Stretch is a characteristic of all wire ropes; constructional stretch initially Steel wires for wire ropes are normally made of non-alloy carbon steel with a carbon content of 0.4 to 0.95%. The very high strength of the rope wires enables wire ropes to support large tensile forces and to run over sheaves with relatively small diameters. In the so-called cross lay strands, the wires of the different layers cross each other. In the mostly used parallel lay strands, the lay length of all the wire layers is equal and the wires of any two superimposed layers are parallel, resulting in linear contact. The wire of the outer layer is supported by two wires of the inner layer. These wires are neighbours along the whole length of the strand. Parallel lay strands are made in one operation. The endurance of wire ropes with this kind of strand is always much greater than of those (seldom used) with cross lay strands. Parallel lay strands with two wire layers have the construction filler, seale or warrington. We offer an extensive range of stainless steel wire & cable. In 1x19, 7x7 and 7x19 constructions in aisi 316 marine grade stainless steel. Sizes 1.5mm to 19mm.
Standard:ul Voltage:600v Capacity:50000 coils/week Tw/thw wires are intended for use as grounding wire and other general purpose power wiring in residential, commercial, and industrial applications. Conductors are solid or stranded annealed or hard uncoated copper. Insulation is a polyvinylchloride (pvc) material applied tightly to the conductor. Surface or indent markings for cable identification Conforms to astm b-3 and ul 83 for copper conductors.
Standard:sans Voltage:600/1000v Capacity:2000km/month Conductor:copper Insulation:xlpe Outer sheath:pvc or pe Innovative solution to the problem of theft of electricity Prevent the resultant loss of revenue Tamper- and vandal-proof Withstand long periods of exposure to ultra-violet radiation Easy installation, no maintenance required after properly installed Airdac has been used by most municipalities, contractors and eskom for the national supply of electrical power to domestic and rural housing projects where conventional and split prepayment meters are being used.
Capacity:2000ton/month Prestressed concrete uses much less materials than reinforced concrete: savings can reach 40% of the overall mass longer spans, thinner and lighter parts allow a reduction in number of piles, height of buildings, consumption of energy in freight and handling, therefore co2 emissions. Low relaxation ensures that no noticeable loss of tension will occur in time, therefore a long lasting compressive force on concrete. Deviated tension is current in post-tensioned structures, stay-cables and even some prefabrication methods. By strict adherence to manufacturing processes and routine destructive tests, our products exceed standard requirements. Stress corrosion and hydrogen embrittlement are known to be a threat for high-tensile structural steels, especially in environments containing chlorides. We manufacture pc strand wire in a 3 or 7-strand configuration in both stress relieved and low relaxation grades. Diameters range from 3/8" (9.53 mm) to .600" (15.24 mm). Prestressing wire and strands are used in bridges, cryogenic storage, industrial, commercial and residential buildings where safety is critical.
Standard:astm b415, b416 Capacity:2000ton/month Corrosion resistant in industrial, semi-industrial and marine environments Superior to aluminized steel Same tensile strength as extra high strength steel but weighs 15 percent less Excellent conductivity much more conductive than galvanized steel and aluminum Wider variety of properties and size of steel wire, thickness of aluminum cladding, and quality of aluminum (cross sectional area ratio of the aluminum in as wire covers approximately 13% to 85% while that designated in astm b415-92 is fixed at 25%) Wider range of combinations of tensile strength and conductivity Sufficiently strong bonding strength at the boundary between aluminum layer and steel core Lighter in weight than galvanized and aluminized steel wire Excellent thermal stability for continuous operation in high temperature
Flexible wires.
Flat Wire.
Standard:hd 21, din vde 0281, bs 6004 Voltage:450/750v Capacity:50000 coils/week The cable is suitable for domestic and light industrial wiring and can be installed on tray, free air or clipped direct. It should be installed into areas where there is low risk of mechanical damage. Resistant to abrasion, heat and moisture. Easy installation.
Standard:bs638 part 4, vde0282-6, cenelec hd22.6 Voltage:200v Capacity:2000km/month Conductor:bare or tinned copper wire class d, 10-120mm2 Separator:separator of synthetic foil or paper Outer sheath:polychloroprene For the transmission of high currents from the electric welding device to the welding tool For flexible use under rough conditions For manually and automatically operated line and spot welding machines On assembly lines and conveyor systems Machine tools Automobile and ship building
Single core wire.
UTP Cat5 Network Cable
Standard:astm a460 Capacity:2000ton/month Ccs wire is an extraordinary conductor that provides benefits that neither metal can provide alone. Because the bulk of the current travels along the wire's skin, it is ideally suited for high-frequency applications. Stranded dsa copper clad steel conductors are used for buried ground grid systems where a more economical alternative to copper conductors is desired. For utility applications, copper clad steel is used in substation and generation plant ground grids; grounding of metal fences; and in building and structure lightning protection systems. Copper clad steel is tough to cut and unlike copper conductors has virtually no scrap recovery value thus reducing the potential of theft or vandalism of the grounding wire. Copper clad steel wire (ccs) is a composite in which highly conductive, corrosion-resistant copper cladding is metallurgically bonded to a strong, durable steel core through a continuous, solid cladding process using pressure rolling for primary bonding. The copper cladding remains at constant thickness surrounding the steel and comprises a small minority of the overall wire diameter, but yields a conductivity substantially greater than that of unclad steel.
Standard:hd 21, din vde 0281, bs 6004, bs 6004 Voltage:600/1000v Capacity:50000 coils/week Applicable standards:bs 6004, iec 60227 Voltage rating:300/500v Temperature rating: 70â°c Core colours:single core: brown or blue Two core:brown and blue Three core:brown, black and grey sheath colour: grey This product is used as hanging cable, drawing cable and installation for field line, electric appliances and instruments, electronic equipment and automatic devices for electric power, chemical and so on.
Standard:iec 245-53, iec 245-66 Voltage:300/500v, 450/750v Capacity:2000km/month Highly flexible Durable service lifespan Resistant to uv-radiation, moisture, oil and fats Conductor:fine stranded copper wire Insulation:rubber compound Outer sheath:rubber compound These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application on construction sites, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant construction, in the chemical industry and painting systems, as well as for the professional and the hobby enthusiast
Standard:iec502, iec332-3 Voltage:5000v Capacity:2000km/month Conductors:annealed (soft) copper, compressed 7 strand Conductor shield (applied on 5kv):extruded semi-conducting xlpe Insulation:black xlpe Sheath (applicable on request):pvc, pe or xlpe Abrasion, moisture, and heat resistant Highly flexible Durable service lifespan Available in several xlpe insulated versions with pvc, pe or xlpe sheaths Airport lighting cable is primarily used for series lighting circuits for runways, control systems, and other multi-purpose installations. It can be used for direct burial, conduit, or raceway. These cables are capable of operating continuously at a conductor temperature not in excess of 90â°c for normal operation, 130â°c for emergency overload conditions, and 250â°c for short circuit conditions. Voltage rating for conductors is 600 volts and 5, 000 volts